Series AM40U-AZ 40 Watt | DC-DC Converter FEATURES: • • • • Models Single output Model AM40U-1203SAZ AM40U-1205SAZ AM40U-1212SAZ AM40U-1215SAZ AM40U-2403SAZ AM40U-2405SAZ AM40U-2412SAZ AM40U-2415SAZ AM40U-4803SAZ AM40U-4805SAZ AM40U-4812SAZ AM40U-4815SAZ Wide Input 2:1 Range Full Internal SMD Technology 1600 VDC Isolation Efficiency up to 89% Input Voltage (V) 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 Output Voltage (V) 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 Adjustable Output Voltage Remote ON/OFF Function Over Load, Voltage & Short Circuit Protection Operating temperature -40oC to + 85oC • • • • Output Current max (A) 8 8 3.3 2.6 8 8 3.3 2.6 8 8 3.3 2.6 Isolation (VDC) Efficiency (%) 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 1600 85 86 86 87 86 88 88 89 87 88 89 89 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating Peak Input Voltage time Input reflected ripple current Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Output Specifications Parameters Voltage accuracy Over voltage protection Over load protection Short Circuit protection Short circuit restart Thermal shutdown Line voltage regulation www.aimtec.com F 051e R12.D Nominal Typical 12 24 48 Maximum 9-18 18-36 36-75 π(Pi) Network 25 12 24 48 VDC Typical 3 sec >1000 220 Conditions Typical ±2 Zener Diode Clamp 135~150 Continuous Auto-Restart 110 ±1 Foldback On Case HL-LL Tel: +1 514 620 2722 1 of 3 ms 36 50 100 100 20 Conditions Units VDC ms mA p-p Rated 1600 Maximum Units VDC MOhm pF Units % % ºC % of Vin Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40U-AZ 40 Watt | DC-DC Converter Output Specifications (continued) Parameters Load voltage regulation (Single) Temperature coefficient Ripple & Noise Voltage adjustment range General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Derating Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Transient recovery time Transient recovery deviation Conditions Iout=10% to 100% Conditions Above 55 oC Maximum Typical Maximum ±2 ±0.02 75 ±10 20MHz Bandwidth 100% load With derating above 55 oC (see graph below) Typical 300 2 Free Air Convection % %/oC mV p-p % Units KHz o -40 to +85 -55 to +125 Units C o 105 95 Nickel – coated Copper 60 2.00 x 2.00 x 0.40 inches 50.81 x 50.81 10.14 mm >1 500 000 hrs ( MIL-HDBK-217 F at +25 oC) 1.5mm from case for 10 sec 260 500 25% load step ±4% of Vout C C %/ oC o % RH g o C uS Safety Specifications Parameters Standards Designed to meet IEC 60950-1:2001 and EN55022:2006 + A1:2007, Class B Pin Out Specifications Pin 1 2 3 4 5 6 7 8 Single +V Input -V Input On/Off Control -Sense +Sense +V Output -V Output Trim www.aimtec.com F 051e R12.D Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM40U-AZ 40 Watt | DC-DC Converter Dimensions 4 50.80 (2.00) 1 5 6 3 7 10.16 (0.40) 27.90 (1.10) 2 8 2.54 (0.10) Printed Face 32.98 (1.30) Bottom View 5.08 5.08 (0.20) 7.62 (0.20) 7.62 (0.30) (0.30) 5.08 (0.20) 50.80 (2.00) 2.54 (0.1) 45.72 (1.80) 10.16 (0.40) Dimensions mm(inch) Case Tolerance ±0.50 (±0.02) Pin Pitch Tolerance ±0.35 (±0.014) 5.08 (0.20) Ø 1.00 (0.04) Derating Trimming Free Air Convection 55º C Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.D Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only