AIMTEC AM4N-Z

Series AM4N-Z
4 Watt | DC-DC Converter
FEATURES:
•
•
•
•
•
•
•
•
RoHS compliant
±20% Input voltage range
Low ripple and noise
High efficiency up to 81%
o
o
Operating temperature -40 C to + 85 C
5KVAC highest reinforced input/ output isolation
Pin compatible with multiple manufacturers
Continuous short circuit protection
Models
Single output
Model
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Isolation
(VAC)
Efficiency
(%)
4-6
4-6
4-6
4-6
9.6-14.4
9.6-14.4
9.6-14.4
9.6-14.4
3.3
5
12
15
3.3
5
12
15
700
700
291
233
700
700
291
233
5000
5000
5000
5000
5000
5000
5000
5000
74
78
80
79
76
80
81
81
AM4N-0503SH50Z
AM4N-0505SH50Z
AM4N-0512SH50Z
AM4N-0515SH50Z
AM4N-1203SH50Z
AM4N-1205SH50Z
AM4N-1212SH50Z
AM4N-1215SH50Z
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
Typical
5
12
Filter
Start up time
Absolute Maximum Rating
Maximum
4-6
9.6-14.4
Capacitors
75
0-7
0-15
80
35
5 Vin
12 Vin
No Load Input Current
Input reflected current(pk-pk)
Units
VDC
ms
VDC
115
mA
mA
Maximum
Units
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
Typical
3 sec
5000
1000
50
VAC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short circuit restart
Short Circuit consumption
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Minimum Load Current
Conditions
Typical
Maximum
±2
Continuous
Autorecovery
%
±0.2
±0.5
±0.02
85
10
From 10% to 100% Load
20MHz Bandwidth
Units
W
% of Vin
%
o
%/ C
mV p-p
% of Max
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
www.aimtec.com
F 051e R12
Conditions
100% load
Typical
570
-40 to +85 (full load without derating)
-55 to +125
Tel: +1 514 620 2722
1 of 4
Maximum
Units
KHz
o
C
o
C
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4N-Z
4 Watt | DC-DC Converter
General Specifications (continued)
Parameters
Conditions
Maximum case temperature
Derating
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Typical
Maximum
Units
o
100
None
1.5mm from case for
10sec
C
o
%/ C
Natural Convection
95
Non Conductive Black Plastic (UL94V-0 rated)
12.5
1.25 x 0.80 x 0.40 inches 31.75 x 20.32 x 10.16 mm
> 1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
260
% RH
g
o
C
Safety Specifications
Parameters
Agency Approvals
Standards
CE
EN 55022 Class A
EN 55024
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
NOTE: also designed to meet IEC 60601-1
Pin Out Specifications
Pin
Single
2
3
11
14
16
22
23
-V Input
-V Input
N.C.
+V Output
-V Output
V+ Input
V+ Input
N.C.: No connection
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4N-Z
4 Watt | DC-DC Converter
Dimensions
27.94
(1.10)
31.75
(1.25)
0.50
(0.02)
10 1112
15.24
(0.60)
0.25
(0.01)
20.32
(0.80)
1 2 3
Bottom View
24 23 22
15 14 13
2.54
(0.10)
Built-in Stand-offs to
ease PCB cleaning
10.15
(0.40)
Printed Face
3.05
(0.12)
All dimensions are typical: millimeters (inches)
Pin Diameter: 0.50 ± 0.05 (0.02 ± 0.002)
Pin Pitch Tolerance: ± 0.35 (±0.014)
Case Tolerence: ± 0.5 (±0.02)
EMI Solution
C2
L1
+V output
+V input
C1
DC/DC
Converter
-V input
Load
-V output
C3
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4N-Z
4 Watt | DC-DC Converter
EFT/Surge Solution
+V output
+V input
DC/DC
Converter
C1
-V input
Load
-V output
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only