Home > Product Details ZUS3 Features UL recognized, TV approved, CSA certified Isolated between input-output Thin profile Built-in Over Current Protection RoHS Compliant 5 year warranty(refer to Instruction Manual) Input Voltage [V] Output Wattage [W] DC Output [V/A] ZUS30505 DC 4.5 - 9 3 5V 0.6A ZUS30512 DC 4.5 - 9 3 12V 0.25A ZUS30515 DC 4.5 - 9 3 15V 0.2A ZUS31205 DC 9 - 18 3 5V 0.6A ZUS31212 DC 9 - 18 3 12V 0.25A ZUS31215 DC 9 - 18 3 15V 0.2A ZUS32405 DC 18 - 36 3 5V 0.6A ZUS32412 DC 18 - 36 3 12V 0.25A ZUS32415 DC 18 - 36 3 15V 0.2A ZUS34805 DC 36 - 72 3 5V 0.6A ZUS34812 DC 36 - 72 3 12V 0.25A ZUS34815 DC 36 - 72 3 15V 0.2A Model Ordering information On-board type ZUS3 ZU 1 S 2 3 3 12 4 DC OUTPUT 5 1Series name 2Single output 3Output wattage 4Input voltage 5Output voltage R MODEL MAX OUTPUT WATTAGE[W] 05 ZUS30505 3 VOLTAGE[V] 5 CURRENT[A] 0.60 ZUS30512 3 12 0.25 ZUS30515 3 15 0.20 ZUS31205 3 5 0.60 ZUS31212 3 12 0.25 ZUS31215 3 15 0.20 ZUS32405 3 5 0.60 ZUS32412 3 12 0.25 ZUS32415 3 15 0.20 ZUS34805 3 5 0.60 ZUS34812 3 12 0.25 ZUS34815 3 15 0.20 ZUS32415 ZUS34805 ZUS34812 DC36 - 72 0.167typ 0.088typ 0.082typ 75typ 71typ 76typ 15 5 12 0.20 0.60 0.25 60max 20max 48max 120max 40max 100max 120max 80max 120max 150max 120max 150max 180max 50max 150max 60max 20max 48max ZUS34815 SPECIFICATIONS ZU/ZT MODEL VOLTAGE[V] *1 CURRENT[A] INPUT *1 EFFICIENCY[%] VOLTAGE[V] CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] *2 RIPPLE[mVp-p] OUTPUT RIPPLE NOISE[mVp-p] *2 TEMPERATURE REGULATION[mV] -20 to +55C *3 DRIFT[mV] START-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] PROTECTION OVERCURRENT PROTECTION CIRCUIT INPUT-OUTPUT ISOLATION INPUT-CASE OUTPUT-CASE OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT SAFETY AGENCY APPROVALS CASE SIZE/WEIGHT OTHERS COOLING METHOD *1 *2 *3 * ZUS30505 ZUS30512 ZUS30515 ZUS31205 ZUS31212 DC4.5 - 9 DC9 - 18 0.896typ 0.857typ 0.857typ 0.357typ 0.338typ 67typ 70typ 70typ 70typ 74typ 5 12 15 5 12 0.60 0.25 0.20 0.60 0.25 20max 48max 60max 20max 48max 40max 100max 120max 40max 100max 80max 120max 120max 80max 120max 120max 150max 150max 120max 150max 50max 150max 180max 50max 150max 20max 48max 60max 20max 48max 20max (Minimum input, Io=100%) ZUS31215 ZUS32405 ZUS32412 DC18 - 36 0.338typ 0.176typ 0.167typ 74typ 71typ 75typ 15 5 12 0.20 0.60 0.25 60max 20max 48max 120max 40max 100max 120max 80max 120max 150max 120max 150max 180max 50max 150max 60max 20max 48max Fixed 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 4.85 - 5.25 11.40 - 12.60 14.25 - 15.75 Works over 105% of rating and recovers automatically AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C) AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C) AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C) -20 to +71C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max 10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis 490.3m/s2 (50G), 11ms, once each X, Y and Z axis UL60950-1, EN60950-1, CSA C22.2 No.60950-1 Complies with IEC60950-1 35X7X23mm (WXHXD) / 16g max Convection Rated input. 5V, 12V, 24V or 48V DC, Io=100% Measured by 20MHz oscilloscope. The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output. Series/Parallel operation with other model is not possible. G-94 0.082typ 76typ 15 0.20 60max 120max 120max 150max 180max 60max ZUS3 External view ¶Recomended size for processing PCB (TOP VIEW) [0.9] [0.6] 15.24 22.86 2-B part ¶Specification at A part 16.51 (2.895) 29.21 4-º1 ±0.1 2.5 1±0.1 0.4 2.5 2.7 (9.245) ¶Specification at B part 0.4 4 7 ±0.3 2-A part 2-º1.6 [0.3] -V 7.62 OUT IN (3.81) -V 23 +V 7.62 7.62 +V Size between case pins Name plate Outline (1.25) (1.25) 22.86 (0.5) 35 6.35 (1.25) 16.51 [0.25] [0.65] (1.25) 4-º1.5 29.21 [1.15] ¶Weight: 16g or less. ¶Tolerance: ± 0.5 ¶Case material: Brass The converter is in contact with the slanted area of the P.C.B. To keep mm isolation, adequate wiring on the ¶Dimensions in mounted side is required. ¶Div.: 0.1inch [inch] Performance data ¡STATIC CHARACTERISTICS (ZUS32405) ¡RISE TIME & FALL TIME (ZUS32405) ZU/ZT ¡OVERCURRENT CHARACTERISTICS (ZUS32405) ¡DERATING CURVE G-95