ETC ZUS152405

Home > Product Details
ZUS15
Features
UL recognized, TV approved, CSA certified
Isolated between input-output
Thin profile
Built-in Over Current Protection
RoHS Compliant
5 year warranty(refer to Instruction Manual)
Input
Voltage
[V]
Output
Wattage
[W]
DC
Output
[V/A]
ZUS15053R3
DC 4.5 - 9
6.6
3.3V
2A
ZUS150505
DC 4.5 - 9
10
5V
2A
ZUS150512
DC 4.5 - 9
12
12V
1A
ZUS151205
DC 9 - 18
12
5V
2.4A
ZUS151212
DC 9 - 18
15.6
12V
1.3A
ZUS152405
DC 18 - 36
12
5V
2.4A
ZUS152412
DC 18 - 36
15.6
12V
1.3A
ZUS15483R3
DC 36 - 75
7.92
3.3V
2.4A
ZUS154805
DC 36 - 75
12
5V
2.4A
ZUS154812
DC 36 - 75
15.6
12V
1.3A
Model
Ordering information
On-board type
ZUS15
ZU
1
S
2
15
3
12
4
05
5
1Series name
2Single output
3Output wattage
4Input voltage
5Output voltage
R
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
ZUS15053R3
6.6
VOLTAGE[V] 3.3
CURRENT[A] 2.0
ZUS150505
10.0
5
2.0
ZUS150512
12.0
12
1.0
ZUS151205
12.0
5
2.4
ZUS151212
15.6
12
1.3
ZUS152405
12.0
5
2.4
ZUS152412
15.6
12
1.3
ZUS15483R3
7.92
3.3
2.4
ZUS154805
12.0
5
2.4
ZUS154812
15.6
12
1.3
SPECIFICATIONS
INPUT
ZU/ZT
OUTPUT
MODEL
VOLTAGE[V]
*1
CURRENT[A]
*1
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*2
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p] *2
TEMPERATURE REGULATION[mV] 0 to +55C
*3
DRIFT[mV]
START-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
ZUS15053R3 ZUS150505 ZUS150512 ZUS151205 ZUS151212 ZUS152405 ZUS152412 ZUS15483R3 ZUS154805 ZUS154812
DC4.5 - 9
DC9 - 18
DC18 - 36
DC36 - 75
1.83typ
2.50typ
2.96typ
1.25typ
1.57typ
0.63typ
0.78typ
0.21typ
0.31typ
0.39typ
72typ
80typ
81typ
80typ
83typ
80typ
83typ
78typ
80typ
83typ
3.3
5
12
5
12
5
12
3.3
5
12
2.0
2.0
1.0
2.4
1.3
2.4
1.3
2.4
2.4
1.3
20max
20max
48max
20max
48max
20max
48max
20max
20max
48max
40max
40max
100max 40max
100max 40max
100max 40max
40max
100max
80max
80max
120max 80max
120max 80max
120max 80max
80max
120max
120max 120max 150max 120max 150max 120max 150max 120max 120max 150max
50max
50max
150max 50max
150max 50max
150max 50max
50max
150max
20max
20max
48max
20max
48max
20max
48max
20max
20max
48max
100max (Minimum input, Io=100%)
Internally fixed (TRM pin open), adjustable by external VR
3.20 - 3.47 t5%
3.20 - 3.47 t5%
3.20 - 3.47 4.85 - 5.25 11.4 - 12.6 4.85 - 5.25 11.4 - 12.6 4.85 - 5.25 11.4 - 12.6 3.20 - 3.47 4.85 - 5.25 11.4 - 12.6
Works over 105% of rating and recovers automatically
4.0 - 5.25V Works at 115 - 140% of rating
4.0 - 5.25V Works at 115 - 140% of rating
Between RC and -side of input:short - 1.2V ---output ON, 2.4V - 5.5V(or open)---output OFF, Compatible to TTL
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
AC500V 1minute, Cutoff current = 10mA, DC500V 50MW min (20t15C)
-20 to +71C, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-40 to +85C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 98.0m/s2 (10G), 3minutes period, 60minutes each along X, Y and Z axis
490.3m/s2 (50G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, CSA C22.2 No.234 Complies with IEC60950-1
45X8.5X50mm (WXHXD) / 55g max
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION
OVERVOLTAGE PROTECTION
CIRCUIT
REMOTE ON/OFF
INPUT-OUTPUT
ISOLATION INPUT-CASE
OUTPUT-CASE
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
SAFETY
AGENCY APPROVALS
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
Convection
*1
*2
*3
*
Rated input. 5V, 12V, 24V or 48V DC, Io=100%
Measured by 20MHz oscilloscope.
The drift is a change at 25C of ambient temperature and 30 minutes - 8 hours after the input voltage applied at rated input/output.
Series/Parallel operation with other model is not possible.
G-80
ZUS15
External view
¶Recomended size for
processing PCB
45
Name plate
(4.72)
note
35.56
6-º1
note)Internal parts
¶Weight: 55g or less.
¶Tolerance: ± 0.5
¶Case material: Aluminum
(5)
[0.6]
[0.2]
35.56
(5)
±0.1
[0.2]
(4.68)
(5)
1
(5)
1
4 8.5± 0.3
(5)
5.08
(5)
-V
TRM
6-º1.5
5.08 15.24
-V
RC
5.08 15.24 5.08
OUT
5.08
15.24
IN
15.24
5.08
+V
[0.2] [0.6]
50
+V
(4.68)
(TOP VIEW)
Outline (5)
(5)
(5)
(5)
[1.4]
(5)
The converter is in contact with the
slanted area of the P.C.B. To keep
isolation, adequate wiring on the ¶Dimensions in mm
mounted side is required.
¶Div.: 0.2inch [inch]
Performance data
¡STATIC CHARACTERISTICS (ZUS151205)
¡RISE TIME & FALL TIME (ZUS151205)
ZU/ZT
¡OVERCURRENT CHARACTERISTICS (ZUS151205)
¡DERATING CURVE
G-81