Ordering information Unit type PBA300F PBA 300 1 2 F 3 -5 -O 4 5 1Series name 2 Output wattage 3 Universal input 4 Output voltage 5 Optional C :with Coating G :Low leakage current U :Operation stop voltage is set at a lower value F3 :Reverse air exhaust type F4 :Low speed fan R Refer to instruction manual 7.1 MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA300F-3R3 198 ACIN 100V 3.3V 60A ACIN 200V *3 3.3V 60A PBA300F-5 300 5V 60A 5V 60A PBA300F-7R5 PBA300F-12 300 324 7.5V 40A 12V 27A 7.5V 40A 12V 27A PBA300F-15 330 15V 22A 15V 22A PBA300F-24 PBA300F-36 336 324 24V 14A 36V 9A 24V 14(16.5)A 36V 9A PBA300F-48 336 48V 7A 48V 7A PBA300F-24 PBA300F-48 SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] INPUT OUTPUT PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 AC85 - 264 1f or DC120 - 350 (AC50 or DC70 optionally available *4) ACIN 100V 3typ 4.1typ ACIN 200V 1.6typ 2typ 50/60 (47 - 63) ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V 68typ 74typ 76typ 78typ 78typ 79typ 81typ 71typ 77typ 79typ 81typ 81typ 82typ 84typ 0.98typ (Io=100%) 0.95typ (Io=100%) 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) LEAKAGE CURRENT[mA] VOLTAGE[V] 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1) 3.3 5 7.5 12 15 24 36 48 ACIN 100V CURRENT[A] ACIN 200V *3 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -20 - 0C *1 60 60 20max 40max 80max 140max 14 14(16.5) 96max 150max 120max 160max 9 9 144max 150max 150max 160max 7 7 192max 300max 150max 400max EFFICIENCY[%] 60 60 20max 40max 80max 140max 40 40 36max 60max 120max 160max 27 27 48max 100max 120max 160max 22 22 60max 120max 120max 160max 79typ 82typ to +50C *1 120max 120max 150max 150max 150max 150max 200max 200max RIPPLE NOISE[mVp-p] 0-20 - 0C *1 160max 160max 180max 180max 180max 180max 240max 500max 0 to +50C *1 40max 50max 75max 120max 150max 240max 360max 480max TEMPERATURE REGULATION[mV] -20 to +50C *1 60max 75max 120max 180max 180max 290max 440max 600max DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192max START-UP TIME[ms] 300typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00 OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92 OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically 6.5 - 8.0 9.0 - 11.6 14.4 - 18.6 18.0 - 23.3 28.8 - 37.2 PROTECTION OVERVOLTAGE PROTECTION[V] 4.3 - 6.3 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Provided REMOTE ON/OFF Provided INPUT-OUTPUT -RC AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) ISOLATION OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) OUTPUT-RC -AUX AC100V 1minute, Cutoff current = 100mA, DC100V 50MWmin (At Room Temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max TEMP.,HUMID.AND ALTITUDE ENVIRONMENT STORAGE VIBRATION IMPACT AGENCY APPROVALS SAFETY AND CONDUCTED NOISE NOISE REGULATIONS CE MARKING HARMONIC ATTENUATOR CASE SIZE/WEIGHT OTHERS COOLING METHOD *1 *2 *3 *4 * PBA300F-36 -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max 19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input) Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Low Voltage Directive, EMC Directive Complies with IEC61000-3-2 102X42X170mm (without terminal block and screw) (WXHXD) /1.0kg max Forced cooling (internal fan) Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. Derating is required.Consult us for details. A sound may occur from power supply at pulse loading. 43.2 - 54.0 57.6 - 80.0