TOTAL-POWER PBA300F-24

Ordering information
Unit type
PBA300F
PBA 300
1
2
F
3
-5
-O
4
5
1Series name
2 Output wattage
3 Universal input
4 Output voltage
5 Optional
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F3 :Reverse air exhaust
type
F4 :Low speed fan
R
Refer to instruction manual
7.1
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA300F-3R3
198
ACIN 100V 3.3V 60A
ACIN 200V *3 3.3V 60A
PBA300F-5
300
5V 60A
5V 60A
PBA300F-7R5 PBA300F-12
300
324
7.5V 40A
12V 27A
7.5V 40A
12V 27A
PBA300F-15
330
15V 22A
15V 22A
PBA300F-24
PBA300F-36
336
324
24V 14A
36V 9A
24V 14(16.5)A 36V 9A
PBA300F-48
336
48V 7A
48V 7A
PBA300F-24
PBA300F-48
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
OUTPUT
PBA300F-3R3 PBA300F-5
PBA300F-7R5 PBA300F-12
PBA300F-15
AC85 - 264 1f or DC120 - 350 (AC50 or DC70 optionally available *4)
ACIN 100V 3typ
4.1typ
ACIN 200V 1.6typ
2typ
50/60 (47 - 63)
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
68typ
74typ
76typ
78typ
78typ
79typ
81typ
71typ
77typ
79typ
81typ
81typ
82typ
84typ
0.98typ (Io=100%)
0.95typ (Io=100%)
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1)
3.3
5
7.5
12
15
24
36
48
ACIN 100V
CURRENT[A]
ACIN 200V *3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C *1
RIPPLE[mVp-p]
-20 - 0C *1
60
60
20max
40max
80max
140max
14
14(16.5)
96max
150max
120max
160max
9
9
144max
150max
150max
160max
7
7
192max
300max
150max
400max
EFFICIENCY[%]
60
60
20max
40max
80max
140max
40
40
36max
60max
120max
160max
27
27
48max
100max
120max
160max
22
22
60max
120max
120max
160max
79typ
82typ
to +50C *1 120max
120max
150max
150max
150max
150max
200max
200max
RIPPLE NOISE[mVp-p] 0-20
- 0C *1 160max
160max
180max
180max
180max
180max
240max
500max
0 to +50C *1 40max
50max
75max
120max
150max
240max
360max
480max
TEMPERATURE REGULATION[mV]
-20 to +50C *1 60max
75max
120max
180max
180max
290max
440max
600max
DRIFT[mV]
*2 12max
20max
30max
48max
60max
96max
144max
192max
START-UP TIME[ms]
300typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100/200V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96
3.96 - 6.00
5.25 - 8.25
8.25 - 13.20
10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
5.00 - 5.15
7.50 - 7.80
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
6.5 - 8.0
9.0 - 11.6
14.4 - 18.6
18.0 - 23.3
28.8 - 37.2
PROTECTION OVERVOLTAGE PROTECTION[V] 4.3 - 6.3
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
Provided
REMOTE ON/OFF
Provided
INPUT-OUTPUT -RC
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
ISOLATION
OUTPUT-RC-AUX-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-RC -AUX
AC100V 1minute, Cutoff current = 100mA, DC100V 50MWmin (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT STORAGE
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
*1
*2
*3
*4
*
PBA300F-36
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input)
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
102X42X170mm (without terminal block and screw) (WXHXD) /1.0kg max
Forced cooling (internal fan)
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
() means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail.
Derating is required.Consult us for details.
A sound may occur from power supply at pulse loading.
43.2 - 54.0
57.6 - 80.0