SERIES: MD2-XXST │ DESCRIPTION: MINI DIN CONNECTOR
FEATURES
• fully shielded
• right angle
• slim style
RoHS
PART NUMBER KEY
MD2 - XX ST
Base Number
Pin Options
40 = 4 pins
60 = 6 pins
SPECIFICATIONS
parameter
conditions/description
min
max
100
12
rated input voltage
rated input current
typ
at 100 Vac
at 12 Vdc
contact resistance
insulation resistance
at 250 Vdc
voltage withstand
for 1 minute
units
Vac
Vdc
1
2
A
A
30
mΩ
50
MΩ
insertion force
250
Vac
4.5
kg
withdrawl force
0.8
3.5
kg
operating temperature
-25
85
°C
life
1,000
cui.com
cycles
CUI Inc │ SERIES: MD2-XXST │ DESCRIPTION: MINI DIN CONNECTOR
date 02/07/2012 │ page 2 of 3
MECHANICAL DRAWINGS
units: mm[inches]
TOLERANCE: ±0.2mm
MATERIAL
PLATING
earth terminal
brass
tin
contact terminals (1~6)
phosphor bronze
silver
plastic
LCP
13.1 0.516
5.0 0.197
0.1
6
11.0 0.433
5.4 0.213
0.15
2.2 0.087
(2 PLCS) 0.3
0.3 0.012
(TYP)
1.6 0.063
0.1
2.4 0.094
0.1
5
4
3
2
3.0 0.118
0.3
7.8 0.307
0.3
4.0 0.157
0.1
1.7 0.067
9.0 0.354
12.8 0.504
1
5.4 0.213
0.4 0.016
1.8 0.071
3.0 0.118
(6 PLCS) 0.3
0.3 0.012
2.0 0.079
0.1
0.45 0.018
(TYP)
2.0 0.079
7.2 0.283
BOTTOM VIEW
MD2-40ST
4
2
2.3 0.091
(2 PLCS)
MD2-60ST
3
6
5
1
2
2.20X1.00
(2 PLCS)
3.00 0.118
2.30 0.091
(2 PLCS)
4
2
2.20X1.00
(2 PLCS)
3.00 0.118
2.30 0.091
(2 PLCS)
2.20 0.087
0.90 0.035
(4 PLCS)
6
4
9.0 0.354
5.4 0.213
12.8 0.504
1
2
12.8 0.504
1
1
3
3
5
7.2 0.283
(4 PLCS)
7.2 0.283
(6 PLCS)
PCB LAYOUT
TOP VIEW
PCB LAYOUT
TOP VIEW
cui.com
2.20 0.087
0.90 0.035
(6 PLCS)
9.0 0.354
5.4 0.213
1.8 0.071
CUI Inc │ SERIES: MD2-XXST │ DESCRIPTION: MINI DIN CONNECTOR
date 02/07/2012 │ page 3 of 3
REVISION HISTORY
rev.
description
date
1.0
initial release
02/23/2006
1.01
new template applied
02/07/2012
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.