For more information, please visit the product page. date 03/12/2012 page 1 of 3 SERIES: MD-XXSKS │ DESCRIPTION: MINI DIN CONNECTOR FEATURES • • • • PCB mount snap-in front terminal right angle side shielded with krinked pins RoHS PART NUMBER KEY MD - XX SKS Base Number Pin Options 30 = 3 pins 40 = 4 pins 50 = 5 pins 60 = 6 pins 70 = 7 pins 80 = 8 pins SPECIFICATIONS parameter conditions/description min rated input voltage rated input current typ max 100 12 at 100 Vac at 12 Vdc contact resistance insulation resistance at 250 Vdc voltage withstand for 1 minute units Vac Vdc 1 2 A A 30 mΩ 250 Vac 50 MΩ insertion force 1 4.5 kg withdrawl force 0.8 3 kg operating temperature -40 life 85 1,000 cui.com °C cycles For more information, please visit the product page. CUI Inc │ SERIES: MD-XXSKS │ DESCRIPTION: MINI DIN CONNECTOR date 03/12/2012 │ page 2 of 3 MECHANICAL DRAWINGS units: mm[inches] TOLERANCE: ±0.2mm MATERIAL PLATING earth terminal brass tin contact terminals (1~8) phosphor bronze silver shield plate steel tin plastic PBT 14.0 0.551 7 8 6 4 5 12.8 0.504 2 12.9 0.508 3 12.5 0.492 1 6.5 0.256 3.5 0.138 (TYP) 3.4 0.134 0.3 0.012 2.0 0.079 4.7 0.185 0.40 0.016 (8 PLCS) 0.7 0.028 (8 PLCS) 5.5 0.217 13.6 0.535 8.5 0.335 11.0 0.433 MD-30SKS MD-40SKS 3 4 1 2 MD-50SKS 4 5 3 2 2 3 1 1 13.5 0.531 13.5 0.531 5.5 0.217 (2 PLCS) 11.0 0.433 4.7 0.185 8.5 0.335 (2 PLCS) 1 5.5 0.217 (2 PLCS) 3 0.7X2.2 (3 PLCS) 0.9 0.035 6.8 0.268 PCB LAYOUT TOP VIEW 4.7 0.185 8.5 0.335 (2 PLCS) 11.0 0.433 (2 PLCS) 2 0.9 0.035 (3 PLCS) 13.5 0.531 0.7X2.2 (3 PLCS) 1 2 3 4 6.8 0.268 PCB LAYOUT TOP VIEW 5.5 0.217 (2 PLCS) 4.7 0.185 8.5 0.335 (3 PLCS) 11.0 0.433 (2 PLCS) 2 0.9 0.035 (4 PLCS) 1 4 5 0.7X2.2 (3 PLCS) 0.9 0.035 (5 PLCS) 1.3 0.051 6.8 0.268 PCB LAYOUT TOP VIEW cui.com 3 For more information, please visit the product page. CUI Inc │ SERIES: MD-XXSKS │ DESCRIPTION: MINI DIN CONNECTOR MD-60SKS 6 date 03/12/2012 │ page 3 of 3 MD-70SKS 5 2 1 13.5 0.531 5.5 0.217 (2 PLCS) 4.7 0.185 8.5 0.335 (4 PLCS) 11.0 0.433 (2 PLCS) 1 2 5 2 1 6 0.7X2.2 (3 PLCS) 2.6 0.102 6.8 0.268 PCB LAYOUT TOP VIEW 4.7 0.185 8.5 0.335 (4 PLCS) 11.0 0.433 (3 PLCS) 3 0.9 0.035 (6 PLCS) 5 1 2 6 3 1 13.5 0.531 5.5 0.217 (2 PLCS) 4 6 4 5 3 2 7 8 5 4 13.5 0.531 3 6 7 3 4 MD-80SKS 4 7 0.7X2.2 (3 PLCS) 4.7 0.185 8.5 0.335 (4 PLCS) 11.0 0.433 (4 PLCS) 0.9 0.035 (7 PLCS) 0.9 0.035 2.6 0.102 5.5 0.217 (2 PLCS) 3 1 6 4 2 7 5 8 0.7X2.2 (3 PLCS) 0.9 0.035 (8 PLCS) 0.9 0.035 2.6 0.102 6.8 0.268 6.8 0.268 PCB LAYOUT TOP VIEW PCB LAYOUT TOP VIEW REVISION HISTORY rev. description date 1.0 initial release 02/23/2006 1.01 new template applied 02/22/2012 1.02 updated housing 03/12/2012 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.