For more information, please visit the product page. date 02/20/2012 page 1 of 3 SERIES: MD-XXCV │ DESCRIPTION: MINI DIN CONNECTOR FEATURES • panel mount • locking nut • plastic bushing RoHS PART NUMBER KEY MD - XX CV Base Number Pin Options 30 = 3 pins 40 = 4 pins 50 = 5 pins 60 = 6 pins 80 = 8 pins SPECIFICATIONS parameter conditions/description min rated input voltage rated input current typ max 100 12 at 100 Vac at 12 Vdc contact resistance insulation resistance at 250 Vdc voltage withstand for 1 minute units Vac Vdc 1 2 A A 30 mΩ 250 Vac 50 MΩ insertion force 1 4.5 kg withdrawl force 0.8 3 kg operating temperature -40 life 85 1,000 cui.com °C cycles For more information, please visit the product page. CUI Inc │ SERIES: MD-XXCV │ DESCRIPTION: MINI DIN CONNECTOR date 02/20/2012 │ page 2 of 3 MECHANICAL DRAWINGS units: mm[inches] MATERIAL PLATING earth terminal brass tin terminal contacts (1~8) phosphor bronze silver housing PBT 14.0 0.551 TOLERANCE: ±0.2mm RECOMMENDED PANEL CUTOUT 9.5 0.374 17.0 0.669 3.5 0.138 1.5 0.059 3.5 0.138 0.5 16.0 0.630 8 7 6 4 5 2 3 0.8 0.031 (TYP) 1 13.5 0.531 M14X1.00 (2 PLCS) MD-30CV MD-40CV 3 4 2 1 MD-50CV 3 2 4 5 1 3 2 1 9.4 0.370 9.4 0.370 5.6 0.220 3 5.6 0.220 0.40 0.016 1.60 0.063 1.9 0.075 1 PCB LAYOUT BACK VIEW 1 0.7X1.3 (2 PLCS) 0.40 0.016 5.6 0.220 4.6 0.181 3 2 0.90 0.035 (3 PLCS) 9.4 0.370 4 0.90 0.035 (4 PLCS) PCB LAYOUT BACK VIEW 4 0.40 0.016 2 4.6 0.181 1.60 0.063 2 0.7X1.3 (2 PLCS) 5 3 1 2.70 0.106 0.90 0.035 (5 PLCS) 1.00 0.039 PCB LAYOUT BACK VIEW cui.com 0.7X1.3 (2 PLCS) For more information, please visit the product page. CUI Inc │ SERIES: MD-XXCV │ DESCRIPTION: MINI DIN CONNECTOR date 02/20/2012 │ page 3 of 3 MD-60CV 6 MD-80CV 8 5 4 2 7 6 4 5 3 3 1 2 1 9.4 0.370 9.4 0.370 5.6 0.220 5.6 0.220 4.6 0.181 1.60 0.063 5 0.40 0.016 3 1 6 2 4.6 0.181 1.60 0.063 7 6 0.40 0.016 4 2.70 0.106 2.4 0.094 1.30 0.051 1.9 0.075 4 1 2 5 2.4 0.094 2.70 0.106 0.7X1.3 (2 PLCS) 1.00 0.039 3 8 0.7X1.3 (2 PLCS) 0.10 0.004 1.00 0.039 0.90 0.035 (6 PLCS) 1.30 0.051 0.90 0.035 (8 PLCS) PCB LAYOUT BACK VIEW PCB LAYOUT BACK VIEW REVISION HISTORY rev. description date 1.0 initial release 02/23/2006 1.01 new template applied 02/20/2012 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.