ROITHNER RLT1060M-1WG

RLT1060M-1WG
TECHNICAL DATA
High Power Infrared Laser Diode
High power, multi mode, broad stripe laser diode, featuring high reliability and long lifetime.
Suitable for many applications including medical laser therapy and defense
Features
•
•
•
•
Lasing Mode Structure: multi mode
Peak Wavelength : typ. 1060 nm
Optical Ouput Power: 1W
Package: TO 9 mm
Electrical Connection
Pin Configuration
Bottom View
n-type
PIN
1
2
3
Function
LD Cathode
LD Anode, PD Anode
PD Anode
Absolute Maximum Ratings (TC=25°C)
Item
CW Output Power
Operating Case Temperature
Storage Temperature
Symbol
PO
TC
Tstg
Value
1000
-20 … +50
-40 … +85
Unit
mW
°C
°C
Specifications (TC=25°C)
Item
Optical Specification
CW Output Power
Peak Wavelength
Spectral Width (FWHM)
Far Field (FWHM)
Emitting Aperature
Lifetime
Electrical Specification
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Photodiode Current
Symbol
Min.
Typ.
Max.
Unit
PO
λP
Δλ
θ║
θ┴
WxH
1055
-
1069
5
11
35
10000
1000
1060
3
8
30
100 x 1
-
-
mW
nm
nm
deg
deg
µm
h
0.8
0.5
0.3
1.4
0.9
1.3
0.7
0.6
1.6
1.6
0.9
mA
A
W/A
V
mA
Ith
Iop
η
Uop
IPD
The above specifications are for reference purpose only and subjected to change without prior notice.
10.05.2012
RLT1060M-1WG
1 of 4
Package Dimensons
9 mm Package (Unit:mm)
10.05.2012
RLT1060M-1WG
2 of 4
Typical Performance Characteristics
Operation Current vs. Output Power
Operation Current vs. Operation Voltage
10.05.2012
RLT1060M-1WG
3 of 4
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the eye or skin directly to
any laser light and/or through optical lens. When handling the LDs, wear appropriate safety
glasses to prevent laser light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye hazard.
•
WARNING: Laserdiode is emitting invisible light
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated strictly below
absolute maximum rating.
10.05.2012
RLT1060M-1WG
4 of 4