ROITHNER QL65I7SA

QL65I7SA
TECHNICAL DATA
Red Laser Diode
Features
•
•
•
•
InGaAlP laser diode
Peak Wavelength: 658 nm
Optical Ouput Power: 30 mW
Package: 5.6 mm, with Photo Diode
Electrical Connection
Pin Configuration
Bottom View
m-type
PIN
1
2
3
Function
LD Cathode
LD Anode, PD Cathode
PD Anode
Absolute Maximum Ratings (TC=25°C)
Item
Symbol
PO (CW)
PO (pulse)
VR (LD)
VR (PD)
TC
Tstg
Optical Output Power
LD Reverse Voltage
PD Reverse Voltage
Operating Case Temperature
Storage Temperature
Value
35
50
2
30
-10 … +70
-40 … +85
Unit
mW
V
V
°C
°C
Specifications (TC=25°C)
Item
Optical Specifications
Optical Output Power (CW)
Peak Wavelength
FWHM Beam Divergence
Emission Point Accuracy
Astigmatism
Electrical Specifications
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Monitor Current
Angle
Symbol
Min.
Typ.
Max.
Unit
PO
λP
θ║
θ┴
Δθ║
Δθ┴
As
7.0
18
-
30
658
9.5
22
-
665
13.0
26
±3.0
±3.0
±60
mW
nm
deg
deg
deg
deg
µm
Ith
Iop
η
Uop
Im
0.7
0.05
35
65
1.0
2.0
0.3
50
100
1.3
2.4
1.5
mA
mA
W/A
V
mA
The above specifications are for reference purpose only and subjected to change without prior notice.
16.02.2011
QL65I7SA
1 of 3
Package Dimensons
5.6 mm Package (Unit:mm)
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the
eye or skin directly to any laser light and/or through optical lens. When
handling the LDs, wear appropriate safety glasses to prevent laser
light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye
hazard.
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
16.02.2011
QL65I7SA
2 of 3
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.