Platinum Resistance Temperature Detector L 220 P L series PRTDs are designed for large volume applications where long term stability, interchangeability and accuracy over a large temperature range are vital. Typical applications are Automotive, White goods, HVAC, Energy management, Medical and Industrial equipment. Nominal Resistance R0 Toler ance DIN EN 60751 1996-07 Tolerance DIN EN 60751 2009-05 Or der Number Plastic Box Order Number V acuum bag 100 Ohm at 0°C Class B F 0.3 32 207 302 32 207 608 The measuring point for the nominal resistance is defined at 8mm from the end of the sensor body. Specification DIN EN 60751 (according to IEC 751) Temperature range -50°C to +400°C (continuous operation) Tolerance class B: -50°C to +400°C Temperature coefficient TCR = 3850 ppm/K Leads AgPd- wire Lead lengths (L) 10mm ±1mm Long-term stability max. R0-drift 0.04% after 1000h at 400°C Vibration resistance at least 40g acceleration at 10 to 2000 Hz, depends on installation Shock resistance at least 100g acceleration with 8ms half sine wave, depends on installation Environmental conditions unhoused for dry environments only Insulation resistance > 100 MΩ at 20°C; > 2 MΩ at 400°C Self heating 0.4 K/mW at 0°C Response time water current (v= 0.4m/s): air stream (v= 2m/s): t0.5 = 0.20s t0.9 = 0.30s t0.5 = 3.0s t0.9 = 9.0s Measuring current 100Ω: 0.3 to 1.0mA (self heating has to be considered) Note Other tolerances, values of resistance and wire lengths are available on request. We reserve the right to make alterations and technical data printed. All technical data serves as a guideline and does not guarantee particular properties to any products. Heraeus Sensor Technology USA 1901 Route 130 North Brunswick, NJ 08902 Phone 732-940-4400 Fax 732-940-4445 Email [email protected] www.hst-us.com Name of document: 30910005 Index A Status: 10/2009