ETC L220P

Platinum Resistance Temperature Detector
L 220 P
L series PRTDs are designed for large volume applications where long term stability, interchangeability and accuracy over
a large temperature range are vital. Typical applications are Automotive, White goods, HVAC, Energy management,
Medical and Industrial equipment.
Nominal
Resistance R0
Toler ance
DIN EN 60751
1996-07
Tolerance
DIN EN 60751
2009-05
Or der Number
Plastic Box
Order Number
V acuum bag
100 Ohm at 0°C
Class B
F 0.3
32 207 302
32 207 608
The measuring point for the nominal resistance is defined at 8mm from the end of the sensor body.
Specification
DIN EN 60751 (according to IEC 751)
Temperature range
-50°C to +400°C (continuous operation)
Tolerance class B: -50°C to +400°C
Temperature coefficient
TCR = 3850 ppm/K
Leads
AgPd- wire
Lead lengths (L)
10mm ±1mm
Long-term stability
max. R0-drift 0.04% after 1000h at 400°C
Vibration resistance
at least 40g acceleration at 10 to 2000 Hz,
depends on installation
Shock resistance
at least 100g acceleration with 8ms half sine
wave, depends on installation
Environmental conditions
unhoused for dry environments only
Insulation resistance
> 100 MΩ at 20°C; > 2 MΩ at 400°C
Self heating
0.4 K/mW at 0°C
Response time
water current (v= 0.4m/s):
air stream (v= 2m/s):
t0.5 = 0.20s
t0.9 = 0.30s
t0.5 = 3.0s
t0.9 = 9.0s
Measuring current
100Ω: 0.3 to 1.0mA
(self heating has to be considered)
Note
Other tolerances, values of resistance and
wire lengths are available on request.
We reserve the right to make alterations and technical data printed. All technical data serves as a guideline and does not guarantee
particular properties to any products.
Heraeus Sensor Technology USA
1901 Route 130
North Brunswick, NJ 08902
Phone 732-940-4400
Fax 732-940-4445
Email [email protected]
www.hst-us.com
Name of document: 30910005 Index A
Status: 10/2009