ZUP Series Zero up programmable power supplies Features u Constant Voltage / Constant Current u Last Setting Memory u Digital Meters u Built-in RS232 & RS485 Interface w/ GPIB optional u Bench or Rack Mount u Embedded Microprocessor Controller u Voltage up to 120V, Current up to 132A Key Market Segments & Applications Specifications Model Load Regulation Line Regulation Recovery Time (1) Temperature Coefficient Temperature Drift(2) Up programming response time Down prog. resp. time (CV) Down prog. resp. time (CV) Load Regulation Line Regulation Temperature Coefficient Temperature Drift(2) Prog Voltage resolution Prog Voltage accuracy Prog Current resolution Prog Current accuracy Overvoltage Shutdown Thermal Protection Display - Voltage Display - Current Display - Status Remote On/Off Output Good Voltage & Current Programming Remote Sense Communication Interface Series & Parallel Operation AC Input Voltage range Inrush Current (100/200VAC)(3) Hold Up Time (Typ) at 100VAC Power Factor Correction Temperature Range Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration & Shock (non-op.) Safety Agency Approvals Conducted & Radiated EMI Warranty ZUP6 ZUP10 ZUP20 ZUP36 ZUP60 ZUP80 ZUP120 2mV + 0.005% over 0 - 100% load change 1mV + 0.005% over 85 - 132 or 170 - 265VAC line change ms 1ms 0.5ms 0.2ms 30ppm/°C following 30 minute warm up 0.01% + 2mV change in output ms 50 - 60ms 80ms 120ms ms 50ms (70ms ZUP60-14) ms 250ms 350ms 400ms 500ms 750ms 600ms 800ms 0.01% + 5mA on 200W and 400W models, 0.07% + 10mA on 800W models 0.01% + 2mA on 200W and 400W models, 0.01% + 5mA on 800W models 100ppm/°C from rated current after 30 minute warm up time 0.02% + 5mA, 200W and 400W models, 0.05% + 10mA 800W models Better than 0.028% of rated voltage mV .02%+5mV .02%+8mV .02%+12mV .02%+20mV .02%+35mV .02%+50mV .02%+70mV Better than 0.03% of rated voltage 0.4% + 40mA V 0 - 7.5 0 - 13 0 - 24 0 - 40 0 - 66 0 - 88 0 - 132 Over temperature protected 3 digits (6, 20, 36, 60, 80V models), 3.5 digits (10, 120V models). Accuracy 0.2% ± 2 digits 3 digits, (3.5 digits 132A model). Accuracy 0.5% ± 3 digits CV / CC, Alarm, Foldback, Local/Remote, On/Off TTL signal or dry contact relay Open Collector By either Voltage (0-4V) or Resistance (0-4k) Up to 0.5V compensation per output cable RS232 & RS485 standard, IEEE488 optional Series: Up to two units; Parallel: Up to five units in master-slave configuration VAC 85-265VAC (47-63Hz) A 15/30A, 200W models, 15A, 400W models, 30A, 800W models ms 20 Complies with EN61000-3 Class A (0.99 typ) Operating: 0 - 50°C; Storage: -20 to +70°C Operating: 30 - 90% RH, Storage 10 - 95%RH Internal fan Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. >100M at 25°C & 70%RH Vibration:10-55Hz(1 min.) 2G constant X, Y, Z, when correctly mounted; Shock: <20G UL3111-1, EN61010-1, CE Mark - EN55022-B conducted, A radiated, FCC Class B conducted, A radiated, VCCI-2 conducted, -1 radiated yrs Three Years Notes: (1) Recovery to within +/-50mV after load change of 50-100% (3) 25°C ambient (cold start) 1-800-526-2324 • www.us.tdk-lambda.com/lp/ (2) Over 8 hour period following 30 minute warm up time 152 Disclaimer: us.tdk-lambda.com/lp/legal.htm ZUP Series Model Selector Model ZUP6-33/U ZUP6-66/U ZUP6-132/U ZUP10-20/U ZUP10-40/U ZUP10-80/U ZUP20-10/U ZUP20-20/U ZUP20-40/U ZUP36-6/U ZUP36-12/U ZUP36-24/U ZUP60-3.5/U ZUP60-7/U ZUP60-14/U ZUP80-2.5/U ZUP80-5/U ZUP120-1.8/U ZUP120-3.6/U Voltage Adjust Range 0-6 0-6 0-6 0-10 0-10 0-10 0-20 0-20 0-20 0-36 0-36 0-36 0-60 0-60 0-60 0-80 0-80 0-120 0-120 Current Adjust Range 0-33 0-66 0-132 0-20 0-40 0-80 0-10 0-20 0-40 0-6 0-12 0-24 0-3.5 0-7 0-14 0-2.5 0-5 0-1.8 0-3.6 Max Power 198 396 792 200 400 800 200 400 800 216 432 864 210 420 840 200 400 216 432 Ripple 5Hz-1MHz mV 5 5 8 5 5 8 5 5 5 5 5 5 5 5 5 30 30 30 30 Options & Accessories Option Model Suffix 5 Front panel terminals (20A max) /L4 Front panel terminals (20A max)6 /L4 IEC320 cable USA plug /U Serial link cable RJ-45 /W GPIB Controller Dual Unit Assembly (accepts 200W or 400W models) 19” 3U rack (accepts up to 6 200/400W models) Blanking panels for NL100 (19 in. rack) RS232 Communications Cable DB-9 RS232 Communications Cable DB-25 RS485 Communications Cable DB-9 RS485 Communications Cable DB-25 User Manual * (See website for more details) 4 Not available with ZUP80 or ZUP120 models. 5 200W and 400W models 6 800W models Noise 20MHz BW mV 50 50 100 50 50 90 50 50 80 50 50 70 50 50 60 80 80 80 80 Ripple 5Hz-1MHz mA 50 100 200 25 50 100 15 30 60 7.5 15 30 5 10 20 5 10 5 10 Efficiency % (100/200VAC) 69 / 72 74 / 77 74 / 77 73 / 77 79 / 82 77 / 81 74 / 78 79 / 83 79 / 82 76 / 80 80 / 84 80 / 84 75 / 79 80 / 84 80 / 84 77 / 82 83 / 87 77 / 82 83 / 87 Weight kg 2.9 3.2 5.8 2.9 3.2 5.8 2.9 3.2 5.8 2.9 3.2 5.8 2.9 3.2 5.8 2.9 3.2 2.9 3.2 Outline Drawing 200/400W Part Number ZUP200/400/L4 ZUP800/L4 ZUP/U ZUP/W GP485A* NL200* NL100* NL101* ZUP/NC401 ZUP/NC403 ZUP/NC402 ZUP/NC404 NL102 Outline Drawing 800W For Additional Information, please visit us.tdk-lambda.com/lp/products/zup.htm 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 153 Revision A6: May 2012