Z+ Series 200 to 800W Programmable Power Supplies Features u 2U high u Built-in USB, RS-232 & RS-485 Interface u Optional LAN, GPIB & Isolated Analog Programming u Bench or Rack Mount u Constant Current or Voltage Modes u Five Year Warranty Key Market Segments & Applications Model Selector Voltage Adjust Current Adjust Max Power Ripple 5Hz-1MHz Noise 20MHz BW Ripple 5Hz-1MHz Efficiency % Front Panel Output Jacks Model Range Z10-20-U Z10-40-U Z10-60-U Z10-72-U Z20-10-U Z20-20-U Z20-30-U Z20-40-U Z36-6-U Z36-12-U Z36-18-U Z36-24-U Z60-3.5-U Z60-7-U Z60-10-U Z60-14-U Z100-2-U Z100-4-U Z100-6-U Z100-8-U 0 - 10 0 - 10 0 - 10 0 - 10 0 - 20 0 - 20 0 - 20 0 - 20 0 - 36 0 - 36 0 - 36 0 - 36 0 - 60 0 - 60 0 - 60 0 - 60 0 - 100 0 - 100 0 - 100 0 - 100 Range (W) (mV) (mV) (mA) (100-200VAC) (Option) 0 - 20 0 - 40 0 - 60 0 - 72 0 - 10 0 - 20 0 - 30 0 - 40 0-6 0 - 12 0 - 18 0 - 24 0 - 3.5 0-7 0 - 10 0 - 14 0-2 0-4 0-6 0-8 200 400 600 720 200 400 600 800 216 432 648 864 210 420 600 840 200 400 600 800 5 5 6.25 6.25 5 5 6.25 6.25 5 5 6.25 6.25 5 5 6.25 6.25 8 8 10 10 50 50 75 75 50 50 75 75 50 50 75 75 50 50 75 75 80 80 100 100 50 50 75 75 30 30 45 45 15 15 22 22 8 8 12 12 3 3 4.5 4.5 80 / 82 80 / 82 80 / 82 80 / 82 82 / 84 81 / 83 82 / 84 82 / 84 83 / 85 83 / 85 84 / 85 84 / 85 83 / 85 83 / 85 83 / 85 83 / 85 83 / 85 84 / 86 84 / 86 84 / 86 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No Factory Installed Options Accessories Option Code Front panel terminals (60V or 24A max)* -L Only one of the options below can be included: GPIB Interface* -IEEE Voltage Programming Isolated Analog Interface* -IS510 Current Programming Isolated Analog Interface* -IS420 LAN Interface (Complies with “LXI” Class C) -LAN Part Number Example Z10-20-LAN-L-U Part Number 19” Rack Housing (Accepts four 105mm width units or six 70mm width units) Blanking Panel for 19” Rack (70mm) Blanking Panel for 19” Rack (105mm) Dual/Triple Housing (Accepts two 105mm case units or three 70mm case units) Serial Link Cable (One is included with each power supply) Communication Cable RS485 Communication Cable RS232 North American Line Cord (One included with -U suffix) Z-NL100 Z-BP Z-WBP Z-NL200 Z-RJ45 Z-485-9 Z-232-9 Z-U *Requires wide body (105mm) case style 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 120 Disclaimer: us.tdk-lambda.com/lp/legal.htm Z+ Series Specifications (See website for detailed specifications) Model Z10 Z20 Z36 Z60 Z100 Load Regulation CV 2mV + 0.01% of rated voltage over 0 - 100% load change Line Regulation CV 2mV + 0.01% of rated voltage over a 85 - 132 or 170 - 265VAC line change Recovery Time (1) CV 1ms Temperature Coefficient CV 30ppm/°C following 30 minute warm up Temperature Stability CV 0.02% of rated voltage over 8 hours following 30 minute warm up time Warm up Drift (2) CV <0.05% of rated voltage + 2mV of rated output voltage Up programming response time (10-90% or 90-10% of Vmax) CV 15ms 30ms 30ms 50ms 50ms Down programming resp time (CV) (10-90% or 90-10% of Vmax) Full load 10ms 30ms 30ms 50ms 50ms Down programming resp time (CV) (90-10% of Vmax) Zero load 190ms 200ms 250ms 310ms 900ms Load Regulation CC 5mA + 0.01% of rated current over 0 - 100% Vout change Load Regulation thermal drift CC < 0.05% of rated current over 30 minutes after load change Line Regulation CC 2mA + 0.01% of rated current over a 85 - 132 or 170 - 265VAC line change Temperature Coefficient CC 100ppm/°C of rated current after 30 minute warm up time Temperature Stability CC 0.05% of rated current over 8 hours following 30 minute warm up time Warm up Drift (2) CC <±0.1% of rated current Vout & Iout programming & readback resolution Digitally < 0.012% of rated voltage/current Vout & Iout programming & readback accuracy Digitally < 0.05% of rated voltage, < 0.1% of rated current Voltage & Current Programming Analog By either Voltage (0-5V or 0-10V) or Resistance (0-5k or 0-10k) Voltage & Current Monitoring Analog 0-5V or 0-10V Voltage (user selectable), ±1% accuracy Overvoltage Shutdown (user programmable) V 0.5 - 12 1 - 24 2 - 40 5 - 66 5 - 110 Overtemperature Protection User selectable - latched or non-latching Display - Voltage 4 digits. Accuracy 0.5% of rated voltage or current ±1 count Remote On/Off By applied voltage or dry contact relay (user selectable logic) Output Good Open Collector, Low on fail Remote Sense Compensation (per wire) V 1 1 2 3 5 Communication Interface RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional Series Operation Up to two identical units (with external diodes) Parallel Operation Up to six units in master-slave configuration Input Voltage / Frequency (3) 85-265VAC, 47-63Hz Inrush Current < 25A Hold Up Time (Typical) ms 16ms Power Factor Correction Complies with EN61000-3-2 Class A (0.99 typ) Operating Temperature °C 0 - 50°C Storage Temperature °C -20 to +85°C Humidity (non condensing) %RH Operating: 10 - 90%RH, Storage 10 - 95%RH Cooling Internal temperature controlled fan Withstand Voltage I/P to GND 2kVAC, I/P to O/P 3kVAC, O/P to GND 1380VDC 1 min Insulation Resistance >100M at 25°C & 70%RH Vibration (non operating) IEC60068-2-64 Shock <20G, half sine, 11ms. IEC60068-2-27 Safety Agency Certifications UL61010-1, EN61010-1, IEC61010 (Designed to meet UL/EN60950-1) Immunity IEC61326 (Designed to meet EN55022 / EN55024) Conducted & Radiated EMI EN55022-B, FCC part 15-B, VCCI-B Size (H x W x D) (Excluding handles and busbars) mm Standard body 83 x 70 x 350mm; Wide Body 83 x 105 x 350mm Weight kg Standard body 1.9kg; Wide Body 2.4kg Warranty yrs Five Years Notes: (1) Recovery to within 0.5% of rated voltage after a load change of 10-90% (Output current 10-100% of Imax) (2) Over 30 minute warm up time after power on (3) Derate for 85-100 VAC; Z10-72-U (66A), Z20-40-U (36A), Z36-24-U (20A), Z60-14-U (12.5A), Z100-8-U (7.5A) 1-800-526-2324 • www.us.tdk-lambda.com/lp/ For Additional Information, please visit us.tdk-lambda.com/lp/products/zplus-series.htm 121 Revision A6: Sep 2012