TDK Z36-18-U

Z+ Series
200 to 800W Programmable Power Supplies
Features
u 2U high
u Built-in USB, RS-232 & RS-485 Interface
u Optional LAN, GPIB & Isolated Analog Programming
u Bench or Rack Mount
u Constant Current or Voltage Modes
u Five Year Warranty
Key Market Segments & Applications
Model Selector
Voltage
Adjust
Current
Adjust
Max
Power
Ripple
5Hz-1MHz
Noise
20MHz BW
Ripple
5Hz-1MHz
Efficiency
%
Front Panel
Output Jacks
Model
Range
Z10-20-U
Z10-40-U
Z10-60-U
Z10-72-U
Z20-10-U
Z20-20-U
Z20-30-U
Z20-40-U
Z36-6-U
Z36-12-U
Z36-18-U
Z36-24-U
Z60-3.5-U
Z60-7-U
Z60-10-U
Z60-14-U
Z100-2-U
Z100-4-U
Z100-6-U
Z100-8-U
0 - 10
0 - 10
0 - 10
0 - 10
0 - 20
0 - 20
0 - 20
0 - 20
0 - 36
0 - 36
0 - 36
0 - 36
0 - 60
0 - 60
0 - 60
0 - 60
0 - 100
0 - 100
0 - 100
0 - 100
Range
(W)
(mV)
(mV)
(mA)
(100-200VAC)
(Option)
0 - 20
0 - 40
0 - 60
0 - 72
0 - 10
0 - 20
0 - 30
0 - 40
0-6
0 - 12
0 - 18
0 - 24
0 - 3.5
0-7
0 - 10
0 - 14
0-2
0-4
0-6
0-8
200
400
600
720
200
400
600
800
216
432
648
864
210
420
600
840
200
400
600
800
5
5
6.25
6.25
5
5
6.25
6.25
5
5
6.25
6.25
5
5
6.25
6.25
8
8
10
10
50
50
75
75
50
50
75
75
50
50
75
75
50
50
75
75
80
80
100
100
50
50
75
75
30
30
45
45
15
15
22
22
8
8
12
12
3
3
4.5
4.5
80 / 82
80 / 82
80 / 82
80 / 82
82 / 84
81 / 83
82 / 84
82 / 84
83 / 85
83 / 85
84 / 85
84 / 85
83 / 85
83 / 85
83 / 85
83 / 85
83 / 85
84 / 86
84 / 86
84 / 86
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Factory Installed Options
Accessories
Option Code
Front panel terminals (60V or 24A max)*
-L
Only one of the options below can be included:
GPIB Interface*
-IEEE
Voltage Programming Isolated Analog Interface*
-IS510
Current Programming Isolated Analog Interface*
-IS420
LAN Interface (Complies with “LXI” Class C)
-LAN
Part Number Example
Z10-20-LAN-L-U
Part Number
19” Rack Housing
(Accepts four 105mm width units or six 70mm width units)
Blanking Panel for 19” Rack (70mm)
Blanking Panel for 19” Rack (105mm)
Dual/Triple Housing
(Accepts two 105mm case units or three 70mm case units)
Serial Link Cable (One is included with each power supply)
Communication Cable RS485
Communication Cable RS232
North American Line Cord (One included with -U suffix)
Z-NL100
Z-BP
Z-WBP
Z-NL200
Z-RJ45
Z-485-9
Z-232-9
Z-U
*Requires wide body (105mm) case style
1-800-526-2324 • www.us.tdk-lambda.com/lp/
120
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Z+ Series
Specifications (See website for detailed specifications)
Model
Z10
Z20
Z36
Z60
Z100
Load Regulation
CV
2mV + 0.01% of rated voltage over 0 - 100% load change
Line Regulation
CV
2mV + 0.01% of rated voltage over a 85 - 132 or 170 - 265VAC line change
Recovery Time
(1)
CV
1ms
Temperature Coefficient
CV
30ppm/°C following 30 minute warm up
Temperature Stability
CV
0.02% of rated voltage over 8 hours following 30 minute warm up time
Warm up Drift
(2)
CV
<0.05% of rated voltage + 2mV of rated output voltage
Up programming response time (10-90% or 90-10% of Vmax)
CV
15ms
30ms
30ms
50ms
50ms
Down programming resp time (CV) (10-90% or 90-10% of Vmax) Full load
10ms
30ms
30ms
50ms
50ms
Down programming resp time (CV) (90-10% of Vmax) Zero load
190ms
200ms
250ms
310ms
900ms
Load Regulation
CC
5mA + 0.01% of rated current over 0 - 100% Vout change
Load Regulation thermal drift
CC
< 0.05% of rated current over 30 minutes after load change
Line Regulation
CC
2mA + 0.01% of rated current over a 85 - 132 or 170 - 265VAC line change
Temperature Coefficient
CC
100ppm/°C of rated current after 30 minute warm up time
Temperature Stability
CC
0.05% of rated current over 8 hours following 30 minute warm up time
Warm up Drift
(2)
CC
<±0.1% of rated current
Vout & Iout programming & readback resolution
Digitally
< 0.012% of rated voltage/current
Vout & Iout programming & readback accuracy
Digitally
< 0.05% of rated voltage, < 0.1% of rated current
Voltage & Current Programming
Analog
By either Voltage (0-5V or 0-10V) or Resistance (0-5k or 0-10k)
Voltage & Current Monitoring
Analog
0-5V or 0-10V Voltage (user selectable), ±1% accuracy
Overvoltage Shutdown (user programmable)
V
0.5 - 12
1 - 24
2 - 40
5 - 66
5 - 110
Overtemperature Protection
User selectable - latched or non-latching
Display - Voltage
4 digits. Accuracy 0.5% of rated voltage or current ±1 count
Remote On/Off
By applied voltage or dry contact relay (user selectable logic)
Output Good
Open Collector, Low on fail
Remote Sense Compensation (per wire)
V
1
1
2
3
5
Communication Interface
RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional
Series Operation
Up to two identical units (with external diodes)
Parallel Operation
Up to six units in master-slave configuration
Input Voltage / Frequency
(3)
85-265VAC, 47-63Hz
Inrush Current
< 25A
Hold Up Time (Typical)
ms
16ms
Power Factor Correction
Complies with EN61000-3-2 Class A (0.99 typ)
Operating Temperature
°C
0 - 50°C
Storage Temperature
°C
-20 to +85°C
Humidity (non condensing)
%RH
Operating: 10 - 90%RH, Storage 10 - 95%RH
Cooling
Internal temperature controlled fan
Withstand Voltage
I/P to GND 2kVAC, I/P to O/P 3kVAC, O/P to GND 1380VDC 1 min
Insulation Resistance
>100M at 25°C & 70%RH
Vibration (non operating)
IEC60068-2-64
Shock
<20G, half sine, 11ms. IEC60068-2-27
Safety Agency Certifications
UL61010-1, EN61010-1, IEC61010 (Designed to meet UL/EN60950-1)
Immunity
IEC61326 (Designed to meet EN55022 / EN55024)
Conducted & Radiated EMI
EN55022-B, FCC part 15-B, VCCI-B
Size (H x W x D) (Excluding handles and busbars) mm
Standard body 83 x 70 x 350mm; Wide Body 83 x 105 x 350mm
Weight
kg
Standard body 1.9kg; Wide Body 2.4kg
Warranty
yrs
Five Years
Notes:
(1) Recovery to within 0.5% of rated voltage after a load
change of 10-90% (Output current 10-100% of Imax)
(2) Over 30 minute warm up time after power on
(3) Derate for 85-100 VAC; Z10-72-U (66A), Z20-40-U
(36A), Z36-24-U (20A), Z60-14-U (12.5A), Z100-8-U
(7.5A)
1-800-526-2324 • www.us.tdk-lambda.com/lp/
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zplus-series.htm
121
Revision A6: Sep 2012