Rast 5 Power Relay 419 01 2 pole 16 A, DC- and AC-coil Features • • • • • • Safety mains insulation Contact gap > 3 mm 4 kV / 8 mm coil-contact Ambient temperature up to 90°C Faston connectors (DIN 46244) Snap or screw mounting Applications Industrial and domestic appliances, absolute safe power supply disconnection F0255-A VZH Technical data of approved types on request Contact data Configuration Type of contact Rated current Rated voltage / max.breaking voltage AC Maximum breaking capacity AC Make current (max. 4 s at duty cycle 10%) Contact material Contact gap Contact ratings Type Load DC-version 16 A, DC-version 12 A, AC-version 16 A, AC-version 12 A, 250 Vac, 250 Vac, 250 Vac, 250 Vac, resistive resistive resistive resistive 2 N/O contact single contact 16 A 250 Vac / 400 Vac 4000 VA 25 A AgCdO, AgNi >3 mm Operations 2.5x105 2.5x105 1x105 1x105 Nominal voltage Nominal coil power Edition: 11/2003 Operate category DC coil AC coil DC coil AC coil 6...24 Vdc 120...400 Vac 1.3 W 2.0...2.5 VA 2/c Coil versions, DC coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vdc Vdc Vdc Vdc c mA 31 12 7.7 0.9 19.5 118+10% 102.0 29 24 15.5 1.8 39.0 470+10% 51.0 Coil versions, AC coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vac, 50 Hz Vac Vac Vac c mA 14 110...120 93.0 18.0 132.0 1650+10% 20.0 10 220...240 187.0 36.0 264.0 6600+10% 10.0 09 380...400 323.0 60.0 440.0 20000+10% 6.0 All figures are given for coil without preenergization, at ambient temperature +20°C Other coil voltages on request Rights to change data / design reserved Coil data Rast 5 Power Relay 419 01 2 pole 16 A, DC- and AC-coil Insulation Dielectric strength coil-contacts open contact circuit Clearance / creepage Insulation to IEC 60664 Voltage rating Pollution degree Overvoltage category Insulation to VDE 0110b (2/79) Insulation category / reference voltage Tracking resistance of relay base 4000 Vrms 2000 Vrms 8 / 8 mm 250 V 3 III C / 380 CTI 600M Other data Ambient temperature Mechanical life Max. switching rate at rated- / minimum load Operate- / release time Bounce time Vibration resistance Shock resistance (destruction) Category of protection (IEC 61810) Relay weight Packaging unit Snap-on mount / Dimensions -20...+90 °C >2x106 operations 15 min-1 / 600 min-1 typ. 15 / 15 ms typ. 4 ms 2 g, 5...500 Hz 80 g RT I - dust protected 90 g 42 pcs. Terminal assignment Dimensions in mm Rights to change data / design reserved Edition: 11/2003 S0447-AA Rast 5 Power Relay 419 01 2 pole 16 A, DC- and AC-coil Screw mount / Dimensions Terminal assignment Dimensions in mm Rights to change data / design reserved Edition: 11/2003 S0447-AB