MA-COM 041901030001

Rast 5 Power Relay 419 01
2 pole 16 A, DC- and AC-coil
Features
•
•
•
•
•
•
Safety mains insulation
Contact gap > 3 mm
4 kV / 8 mm coil-contact
Ambient temperature up to 90°C
Faston connectors (DIN 46244)
Snap or screw mounting
Applications
Industrial and domestic appliances, absolute safe power supply
disconnection
F0255-A
VZH
Technical data of approved types on request
Contact data
Configuration
Type of contact
Rated current
Rated voltage / max.breaking voltage AC
Maximum breaking capacity AC
Make current (max. 4 s at duty cycle 10%)
Contact material
Contact gap
Contact ratings
Type
Load
DC-version 16 A,
DC-version 12 A,
AC-version 16 A,
AC-version 12 A,
250 Vac,
250 Vac,
250 Vac,
250 Vac,
resistive
resistive
resistive
resistive
2 N/O contact
single contact
16 A
250 Vac / 400 Vac
4000 VA
25 A
AgCdO, AgNi
>3 mm
Operations
2.5x105
2.5x105
1x105
1x105
Nominal voltage
Nominal coil power
Edition: 11/2003
Operate category
DC coil
AC coil
DC coil
AC coil
6...24 Vdc
120...400 Vac
1.3 W
2.0...2.5 VA
2/c
Coil versions, DC coil
Coil
Nominal
Pull-in
Release
Maximum
Coil
Coil
code
voltage
voltage
voltage
voltage
resistance
current
Vdc
Vdc
Vdc
Vdc
c
mA
31
12
7.7
0.9
19.5
118+10%
102.0
29
24
15.5
1.8
39.0
470+10%
51.0
Coil versions, AC coil
Coil
Nominal
Pull-in
Release
Maximum
Coil
Coil
code
voltage
voltage
voltage
voltage
resistance
current
Vac, 50 Hz
Vac
Vac
Vac
c
mA
14
110...120
93.0
18.0
132.0
1650+10%
20.0
10
220...240
187.0
36.0
264.0
6600+10%
10.0
09
380...400
323.0
60.0
440.0
20000+10%
6.0
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
Rights to change data / design reserved
Coil data
Rast 5 Power Relay 419 01
2 pole 16 A, DC- and AC-coil
Insulation
Dielectric strength
coil-contacts
open contact circuit
Clearance / creepage
Insulation to IEC 60664
Voltage rating
Pollution degree
Overvoltage category
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage
Tracking resistance of relay base
4000 Vrms
2000 Vrms
8 / 8 mm
250 V
3
III
C / 380
CTI 600M
Other data
Ambient temperature
Mechanical life
Max. switching rate at rated- / minimum load
Operate- / release time
Bounce time
Vibration resistance
Shock resistance (destruction)
Category of protection (IEC 61810)
Relay weight
Packaging unit
Snap-on mount / Dimensions
-20...+90 °C
>2x106 operations
15 min-1 / 600 min-1
typ. 15 / 15 ms
typ. 4 ms
2 g, 5...500 Hz
80 g
RT I - dust protected
90 g
42 pcs.
Terminal assignment
Dimensions in mm
Rights to change data / design reserved
Edition: 11/2003
S0447-AA
Rast 5 Power Relay 419 01
2 pole 16 A, DC- and AC-coil
Screw mount / Dimensions
Terminal assignment
Dimensions in mm
Rights to change data / design reserved
Edition: 11/2003
S0447-AB