MACOM 44M9976-30

• Dual wall construction
• 600, 1000 and 2500 voltage rating
• Small size, light weight
Spec 44
Wire and cable
• Low smoke and low corrosive
gas generation
• Resistant to most chemicals
and electrical arc tracking
Spec 44 wire has a dual wall construction
which combines the outstanding physical
and electrical characteristics of radiation
crosslinked polyalkene with the excellent
mechanical and chemical properties of
radiation cross-linked polyvinylidene
fluoride (PVDF).
The result is a wire insulation system that
offers a 150°C temperature rating, small
size, light weight,solder iron resistance,
and resistance to most solvents, fuels and
lubricants. Spec 44 wire and cable is
highly flame retardant, non-melting, does
not cold flow, and though mechanically
very tough, is easy to handle and install
using conventional tools.
Originally developed for aerospace and
military requirements in applications of
high density and complex circuitry, Spec
44 wire and cable now finds wide use
throughout industry, in commercial and
military electronics, avionics, on satellites,
aircraft, helicopters, ships, trains, and
offshore platforms where environmental
conditions demand consistently reliable
performance. In airframe applications
Spec 44 constructions can offer a modern
dimensional replacement for PVC/Nylon/
Glass braid type wire and cables. Spec 44
wire is offered in a wide range of sizes in
stranded conductors, standard materials
available being tin or silver-plated copper
and high strength copper alloy. Voltage
ratings of 600, 1000 and 2500 volts are
available as standard. Shielded and
jacketed versions include single and
multi-conductor constructions and flat
braid shields where further size and
weight savings are achieved.
44 wire
Conductor
Primary Insulation Radiation Crosslinked,
Extruded Polyalkene
Jacket Radiation Crosslinked,
Modified PVDF
44 cable (twisted pair)
Specifications/Approvals
Mil-W-81044, Mil-C-27500 (Cables)
Def Stan. 61-12 Part 18 Issue 4 - Type 1 pliable (Maintenance Range)
Def Stan. 61-12 Part 26 Issue 2 Type 1, 2, 3, 7, 8, 9 & METS 7, 8 & 9
VG 95218 Parts 20, 21, 22, 23 and 1000
NATO Stock numbers (NSN's) exist for most standard constructions
Civil Aviation Authority Accessory Approval E11623
Lloyds Register of Shipping
NASA Preferred Product List
Raychem Specification 44
Spec 44
Physical characteristics
Small size
Spec 44 equipment wire, 600 volt rated has a
0.19 mm nominal wall thickness compared to
0.25 mm and 0.38 mm for equivalent PTFE and
PVC wires in MIL-W-16878, MIL-W-22759
or BS G210.
Light weight
Because of the thin wall and low density of the
insulation materials considerable weight savings
are made over similarly rated PTFE wires, eg:-
44A0111-22AWG equipment wire
4.62 grams/metre max
22AWG PTFE equipent wire,
MIL-W-22759
5.54 grams/metre max
General handling
The flexibility of Spec 44 and the ease with
which it takes a 'set' makes it one of the easiest
of the 'high performance' wires to install.
Stripping is done with conventional die blade
strippers.
For details of appropriate tools see separate
wire handling guide. The tin-plated conductor
usually specified is easily soldered or crimped.
The insulation may be hot stamp marked or
printed and does not need etching before
potting.
Lengths
Spec 44 is available in long continuous lengths
and can be supplied for use on automatic cut
and strip wire preparation machines.
Temperature rating
-65°C to +150°C
Typical properties
Voltage rating (thin wall)
600 V
Voltage rating (thick wall)
2500 V
Tensile strength and elongation of insulation
30 N/mm2, 230%
Notch propagation, 0.05mm notch
Pass
Solder iron resistance (370°C, 1 minute)
Pass
Shrinkage, 200°C
<1%
Low temperature bend
-65°C
Voltage withstand (thin wall)
2500 V
Insulation resistance (20°C)
1500 M ohms for 1 km
Resistance: fuels, oils, solvents
Pass
Environmental performance
Temperature rating
Spec 44 wire and cable is rated for continuous
operation from -65°C to +150°C and for short
periods at temperatures as high as 300°C. Heat
ageing tests are routinely performed at
temperatures of 200°C (168 h) and 300°C (6 h).
In addition Spec 44's insulation will not shrink
back under repeated cycling.
Mechanical performance
Spec 44 wire provides better cut through
resistance than some wires with much thicker
walls. 600 volt equipment wire 44A0111 (0.19
mm wall) has 40% greater cut through
resistance than 600 volt PTFE insulated wire
(0.25 mm wall).
Solder iron/Overload resistance
The radiation crosslinking of the materials used
in Spec 44 makes them non-melting at high
temperature. As a result Spec 44 wire is
resistant to prolonged contact with solder irons
and is resistant to current overloads which
would melt most thermoplastic insulations.
Chemical resistance
The irradiated dual wall construction of Spec
44 wire is highly resistant to many acids, alkalis,
hydrocarbon solvents,fuels, lubricants, water
and many missile fuels and oxidisers.
Cold flow
Radiation cross-linking of Spec 44 prevents
cold flow of the insulation - a recognised
problem of some uncrosslinked materials.
Voltage ratings
Standard available voltage ratings for Spec 44
wire are 600 volts (0.19 mm wall thickness),
1000 volts (0.28 mm wall) and 2500 volts
(0.48 mm wall).
Electrical arc track resistance
Spec 44 insulation demonstrates a total
resistance to arc tracking under both wet and
dry conditions at aircraft system voltages.
Low outgassing
For use in space applications, special
constructions of Spec 44 wire are available
with low outgassing characteristics, for use in
an environment of high vacuum and high
temperature.
Fire hazard performance
Flammability
Smoke/Toxicity Index
BS4066 vertical flammability
Pass
S424 14751 (Swedish chimney)
Pass
NFC 32070 (2) (French chimney)
Pass
IEC 332 part 3 (Cable ladder)
Pass
Smoke Index, Def Stan 61-12 (18)
6 per metre of wire
Toxicity Index, Def Stan 61-12 (18)
0.8 per metre of wire
Oxygen Index, NES 714
30% Oxygen
Temperature Index, NES 715
>300°C
Spec 44
Spec 44 wire and cable - nominal sizes, strandings and weights
Primary wires/Twisted pair
44A011X (600 V)
primary wire
Stranding CSA
OD
Weight
Size (mm)
(mm2)
(mm)
(g/m)
30 7/0.10
0.06
0.68
1.00
28 7/0.13
0.09
0.76
1.36
26* 19/0.10
0.15
0.86
1.98
24 19/0.13
0.25
1.02
2.97
22 19/0.16
0.40
1.19
4.38
20 19/0.20
0.60
1.40
6.50
18 19/0.25
1.00
1.65
9.90
16 19/0.29
1.25
1.83
12.58
14 19/0.36
2.00
2.26
19.65
12 37/0.32
3.00
2.74
30.68
10 37/0.40
5.00
3.28
46.28
8 133/0.29
*For 44A0211-26 the stranding is 7/0.16mm
44A021X (1000 V) 44A031X (2500 V) 44A081X (600 V)
primary wire
primary wire
airframe wire
44A012X (600 V)
twisted pair
OD
(mm)
Weight
(g/m)
OD
(mm)
Weight
(g/m)
OD
(mm)
Weight
(g/m)
1.02
1.17
1.37
1.57
1.85
2.06
2.49
2.98
3.73
5.23
1.49
2.23
3.43
4.92
7.30
10.90
13.88
20.90
31.34
50.4
87.6
1.44
1.75
1.98
2.23
2.46
2.92
3.32
4.09
5.56
4.18
6.12
8.65
12.38
15.37
23.13
34.32
54.02
96.20
1.37
1.57
1.78
2.03
2.26
2.74
3.20
3.94
5.44
3.73
5.52
7.91
11.49
14.32
22.08
32.23
51.80
92.94
OD
(mm)
1.37
1.52
1.73
2.03
2.38
2.79
3.30
3.65
4.52
5.48
Weight
(g/m)
2.12
2.90
4.10
6.08
8.91
13.30
20.21
25.73
40.15
62.63
Screened and jacketed cable
44A111X (600 V)
1 conductor
44A121X (6000 V)
1 conductor
44A181X (600 V)
1 conductor
Stranding
OD
Weight OD
Weight
OD
Size (mm)
(mm)
(g/m)
(mm)
(g/m)
(mm)
30 7/0.10
28 7/0.13
1.60
5.33
26 19/0.10
1.57
5.82 1.73
6.51
24 19/0.13
1.83
8.20 1.98
9.18
2.26
22 19/0.16
2.00
10.30 2.24
12.35
2.57
20 19/0.20
2.26
14.02 2.54
17.40
2.77
18 19/0.25
2.62
19.70 2.82
22.61
3.02
16 19/0.29
2.79
23.40 3.02
26.63
3.25
14 19/0.36
3.22
32.50 3.45
36.15
3.73
12 37/0.32
3.70
45.67 4.14
49.55
4.19
Size 10 to 4 also available in some constructions depending on conductor type and construction required.
Weight
(g/m)
11.69
15.39
19.09
23.98
27.97
38.48
52.10
44A112X (600 V)
2 conductors
OD
(mm)
2.23
2.38
2.59
2.99
3.35
3.76
4.32
4.67
5.53
6.50
Weight
(g/m)
8.20
9.40
12.05
16.12
21.50
27.97
38.24
44.93
64.28
91.51
Spec 44 wire and cable (Def Stan 61-12 Part 18 Issue 4 Type 1) (Maintenance)
Limited fire hazard equipment wire (pliable)
Cable electrical - Type 1SBM screened and jacketed
Diameter
Diameter
Diameter
over
Raychem
over
over
Raychem
Conductor Stranding insulation
Weight
part
screen
jacket
Weight
part
size
(mm)
(mm)
(gm/m)
number
(mm)
(mm)
(gm/m)
number
30
7/0.10 0.68
1.00
44M9976-30-†
28
7/0.12 0.73
1.40
44M9976-28-†
26
19/0.10 0.88
2.00
44M9976-26-†
1.33
1.80
7.5
44M9995-26-†-†
24
19/0.12 0.98
3.00
44M9976-24-†
1.43
1.90
9.2
44M9995-24-†-†
22
19/0.15 1.13
4.40
44M9976-22-†
1.58
2.05
11.1
44M9995-22-†-†
20
19/0.20 1.40
6.55
44M9976-20-†
1.83
2.30
14.6
44M9995-20-†-†
18
19/0.25 1.65
9.90
44M9976-18-†
2.08
2.55
19.3
44M9995-18-†-†
16
19/0.30 1.90
14.15
44M9976-16-†
2.48
2.95
24.9
44M9995-16-†-†
14
37/0.25 2.25
18.62
44M9976-14-†
2.65
3.13
30.9
44M9995-14-†-†
12
37/0.30 2.60
25.70
44M9976-12-†
3.00
3.48
43.4
44M9995-12-†-†
The cable jackets on type 1SBM are specified black to Def. Stan. 61-12 pt 31, other colours are available.
†Colour code suffix - see part numbering system. Single and multicore screened and jacketed cables are available using Type1 components.
Spec 44
Part numbering system
44
X
X
X
X
X-
Size-
X/X- X
Jacket colour
(in accordance with MIL-STD-681,
white preferred)
Primary wire insulation colour
(in accordance with MIL-STD-681)
0=Black
3=Orange
7=Violet
1=Brown
4=Yellow
8=Grey
2=Red
5=Green
9=White
2L=Pink
6=Blue
Additional number after base colour
indicates stripe
Conductor size
Conductor type
1 - Tin-plated copper
2 - Silver-plated copper
4 - Silver-plated high strength copper alloy
(SPHSCA)
Number of conductors
1-9
Class of wire
1 - 600 V equipment wire
2 - 1000 V equipment wire
3 - 2500 V equipment wire
4 - Space wire 600 V
8 - Airframe wire - medium weight
Constructions
0 - Primary wire & unscreened,
unjacketed cables
1 - Round braid screened & jacketed†
2 - Flat braid screened & jacketed†
3 - Round braid, screened, no jacket†
4 - Jacketed, no screen
5 - Spirally screened & jacket
7 - 9 Special constructions
†
Screen material same as conductor
material except screen for type 4
conductor is tinned copper
Type
A- AWG conductor
M - Metric conductor
AM - Special
CD - Custom Design
B - Special
/ - Space & specials
D - Defence Standard 61-12 Part 26
Basic specification number
Typical ordering example
3 conductors, brown, yellow with green stripe, blue, white jacket. If 600 volt, round braid,
20 AWG tinned conductor, total part number is 44A1131-20-1/45/6-9.
Ordering information
Standard equipment wires (44A0111 12 to 30 AWG) in most common AWGs and colours are
kept in stock. In addition, many of the most commonly used single/pair and triple screened cables
are also stock items, as are some airframe constructions.
Other constructions and custom designed wire and cable are available on request.
Raychem and Spec 44 are trademarks of Tyco Electronics Corporation.
All of the above information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their
application. Tyco Electronics makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use. Tyco Electronics
only obligations are those in the Standard Terms and Conditions of Sale for this product and in no case will Tyco Electronics be liable for any incidental, indirect or
consequential damages arising from the sale, resale, use or misuse of the product. Tyco Electronics Specifications are subject to change without notice. In addition
Tyco Electronics reserves the right to make changes in materials or processing, without notification to the Buyer, which do not affect compliance with any applicable
specification.
Tyco Electronics Corporation
300 Constitution Drive
Menlo Park, CA 94025-1164
USA
Tel: (800)-926 2425 (US and Canada)
Tel: +1 650 361 3860 (All other countries)
Tyco Electronics UK Ltd
Faraday Road, Dorcan,
Swindon, Wiltshire SN3 5HH
Tel: (44)-1793-528171
Tyco Electronics Raychem K.K.
3816 Noborito, Tama-ku
Kawasaki
Kanagawa 214-8533
Japan
Tel: +81 44 900 5102
Raychem Singapore PTE Ltd.
26 Ang Mo Kio
Industrial Park 2
Singapore 569507
Tel: +65 4866151
www.tycoelectronics.com
WC0007.0200