C-Series Datasheet

C Series
Low-Noise Switch Mode Power Supplies
With User-Configurable Multiple Outputs
The C Series power supplies save design and production time and
cost by allowing end-of-line selection of multiple output voltages
to match alternative application circuit requirements, while using
the same power supply base unit. DC voltage output modules are
slot-mounted inside the base units to provide various combinations
of single, dual, or parallel output voltages.
Base
ase U
Units
s
C300
300 W
C450
450 W
C650
650 W
Features and Benefits
• DC modules can be easily substituted to handle a wide range of
voltage combinations:
▫ Single output: 3.3 V / 5 V / 12 V / 15 V / 24 V
▫ Dual output: ±12 V / ±15 V
▫ Parallel drive: 24 V 132 W
• Modular design eliminates individual safety approvals
• High reliability with low noise
• High withstand voltage and low leakage current
• OCP, OVP, and OHP, remote sensing and control, and alarm for
AC power failure, fan failure, and low output fault
DC output modules slide into Base Units
Applications
• General industrial and commercial equipment
• Medical and information equipment (approved to
UL60950-1, C-UL, EN60950 and EN60601-1 3rd )
Plug-in connection
Single screw mounting
Base Unit Specifications
Total Output Power
DC Modules Capacity
Auxiliary Outputs
C300
C450
C650
300 W
450 W
650 W
4 modules
5 modules
5 modules
(1 isolated)
1 auxiliary 12 V
1 auxiliary 12 V
2 auxiliary 12 V
(1 isolated)
Rated Input Voltage
100 / 240 VAC
Input Current
2.0 A
3.1 A
Rated Frequency
Power Factor
0.95
Inrush Current
20 A / 40 A
Efficiency
87% / 89%
89% / 91%
Leakage Current
89% / 92%
0.3 mA (max) / 0.5 mA (max)
20 ms (typ) at 100 VAC and IO = 100%
Hold-Up Time
Safety Standard
UL60950-1, UL60601-1, EN60950-1, EN60601-1, C-UL
Conducted Noise
Comply with FCC-B, VCC I-B, CISPR22-B, EN55022-B
Harmonic Attenuator
Comply with IEC61000-3-2
Cooling
Forced Air (Built-in fan)
Operation Temperature and Humidity
–20°C to 70°C, 20% to 90% RH (Load derating above 50°C)
Storage Temperature and Humidity
Dimensions (mm)
C-PD01
4.2 A
50 to 60 Hz
–20°C to 75°C, 20% to 90% RH
63.5 × 254 × 103
63.5 × 254 × 127
SANKEN ELECTRIC CO., LTD.
http://www.sanken-ele.co.jp/en/
63.5 × 279 × 127
July 17, 2013
C Series Modular Power Supplies
DC Modules Electrical Specifications
Single Output
150 W
Dual Output
75 W
Single Output
50 W
Parallel
Connection
Important Information
Model
Number
Voltage
(V)
Wattage
(W)
Current
(A)
Ripple/
Noise
(mVPP)
Voltage
Range
(V)
C150S03
+3.3
85.8
26
180
3.2 to 3.3
Voltage
Regulation
(%)
C150S05
+5
130
26
180
4.8 to 5.1
C150S12
+12
156
13
200
11.6 to 12.3
C150S15
+15
150
10
200
14.5 to 15.4
C150S24
+24
156
6.5
180
22.8 to 24.7
C075M12
±12
76.8
3.2
200
11.6 to 12.3
C075M15
±15
75
2.5
200
14.5 to 15.4
C050S03
+3.3
33
10
180
3.2 to 3.3
C050S05
+5
50
10
180
4.8 to 5.1
C050S12
+12
60
5
200
11.6 to 12.3
C050S15
+15
60
4
200
14.5 to 15.4
C050S24
+24
60
2.5
180
22.8 to 24.7
±5
C130x24
+24
132
5.5
250
22.8 to 24.7
±5
±3
±5
±3
±3
!
• The products described in this document are built-in type DC stabilized power supplies with special structures and are designed for installation in
equipment. Be sure to use the products only for installation in equipment.
• The products should be handled only by persons who have competent electrical knowledge.
• Be sure to read through all safety precaution and operation manuals before installation, operation, or maintenance and to use the products only for
the intended use and in accordance with all applicable safety standards and regulations in the location of use.
Sanken reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the performance, reliability, or
manufacturability of its products. Therefore, the user is cautioned to verify that the information in this publication is current before placing any order.
When using the products described herein, the applicability and suitability of such products for the intended purpose shall be reviewed at the users' responsibility.
Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and defect of semiconductor products at a certain rate is inevitable.
Users of Sanken products are requested to take, at their own risk, preventative measures including safety design of the equipment or systems against any possible injury, death, fires or damages
to society due to device failure or malfunction.
Sanken products listed in this publication are designed and intended for use as components in general-purpose electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Their use in any application requiring radiation hardness assurance (e.g., aerospace equipment) is not supported.
When considering the use of Sanken products in applications where higher reliability is required (transportation equipment and its control systems or equipment, fire- or burglar-alarm systems,
various safety devices, etc.), contact a company sales representative to discuss and obtain written confirmation of your specifications.
The use of Sanken products without the written consent of Sanken in applications where extremely high reliability is required (aerospace equipment, nuclear power-control stations, life-support
systems, etc.) is strictly prohibited.
The information included herein is believed to be accurate and reliable. Application and operation examples described in this publication are given for reference only and Sanken assumes no
responsibility for any infringement of industrial property rights, intellectual property rights, or any other rights of Sanken or any third party that may result from its use. The contents in this
document must not be transcribed or copied without Sanken’s written consent.
C-PD01
SANKEN ELECTRIC CO., LTD.
2
July 17, 2013