C Series Low-Noise Switch Mode Power Supplies With User-Configurable Multiple Outputs The C Series power supplies save design and production time and cost by allowing end-of-line selection of multiple output voltages to match alternative application circuit requirements, while using the same power supply base unit. DC voltage output modules are slot-mounted inside the base units to provide various combinations of single, dual, or parallel output voltages. Base ase U Units s C300 300 W C450 450 W C650 650 W Features and Benefits • DC modules can be easily substituted to handle a wide range of voltage combinations: ▫ Single output: 3.3 V / 5 V / 12 V / 15 V / 24 V ▫ Dual output: ±12 V / ±15 V ▫ Parallel drive: 24 V 132 W • Modular design eliminates individual safety approvals • High reliability with low noise • High withstand voltage and low leakage current • OCP, OVP, and OHP, remote sensing and control, and alarm for AC power failure, fan failure, and low output fault DC output modules slide into Base Units Applications • General industrial and commercial equipment • Medical and information equipment (approved to UL60950-1, C-UL, EN60950 and EN60601-1 3rd ) Plug-in connection Single screw mounting Base Unit Specifications Total Output Power DC Modules Capacity Auxiliary Outputs C300 C450 C650 300 W 450 W 650 W 4 modules 5 modules 5 modules (1 isolated) 1 auxiliary 12 V 1 auxiliary 12 V 2 auxiliary 12 V (1 isolated) Rated Input Voltage 100 / 240 VAC Input Current 2.0 A 3.1 A Rated Frequency Power Factor 0.95 Inrush Current 20 A / 40 A Efficiency 87% / 89% 89% / 91% Leakage Current 89% / 92% 0.3 mA (max) / 0.5 mA (max) 20 ms (typ) at 100 VAC and IO = 100% Hold-Up Time Safety Standard UL60950-1, UL60601-1, EN60950-1, EN60601-1, C-UL Conducted Noise Comply with FCC-B, VCC I-B, CISPR22-B, EN55022-B Harmonic Attenuator Comply with IEC61000-3-2 Cooling Forced Air (Built-in fan) Operation Temperature and Humidity –20°C to 70°C, 20% to 90% RH (Load derating above 50°C) Storage Temperature and Humidity Dimensions (mm) C-PD01 4.2 A 50 to 60 Hz –20°C to 75°C, 20% to 90% RH 63.5 × 254 × 103 63.5 × 254 × 127 SANKEN ELECTRIC CO., LTD. http://www.sanken-ele.co.jp/en/ 63.5 × 279 × 127 July 17, 2013 C Series Modular Power Supplies DC Modules Electrical Specifications Single Output 150 W Dual Output 75 W Single Output 50 W Parallel Connection Important Information Model Number Voltage (V) Wattage (W) Current (A) Ripple/ Noise (mVPP) Voltage Range (V) C150S03 +3.3 85.8 26 180 3.2 to 3.3 Voltage Regulation (%) C150S05 +5 130 26 180 4.8 to 5.1 C150S12 +12 156 13 200 11.6 to 12.3 C150S15 +15 150 10 200 14.5 to 15.4 C150S24 +24 156 6.5 180 22.8 to 24.7 C075M12 ±12 76.8 3.2 200 11.6 to 12.3 C075M15 ±15 75 2.5 200 14.5 to 15.4 C050S03 +3.3 33 10 180 3.2 to 3.3 C050S05 +5 50 10 180 4.8 to 5.1 C050S12 +12 60 5 200 11.6 to 12.3 C050S15 +15 60 4 200 14.5 to 15.4 C050S24 +24 60 2.5 180 22.8 to 24.7 ±5 C130x24 +24 132 5.5 250 22.8 to 24.7 ±5 ±3 ±5 ±3 ±3 ! • The products described in this document are built-in type DC stabilized power supplies with special structures and are designed for installation in equipment. Be sure to use the products only for installation in equipment. • The products should be handled only by persons who have competent electrical knowledge. • Be sure to read through all safety precaution and operation manuals before installation, operation, or maintenance and to use the products only for the intended use and in accordance with all applicable safety standards and regulations in the location of use. Sanken reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the performance, reliability, or manufacturability of its products. Therefore, the user is cautioned to verify that the information in this publication is current before placing any order. When using the products described herein, the applicability and suitability of such products for the intended purpose shall be reviewed at the users' responsibility. Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures including safety design of the equipment or systems against any possible injury, death, fires or damages to society due to device failure or malfunction. Sanken products listed in this publication are designed and intended for use as components in general-purpose electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Their use in any application requiring radiation hardness assurance (e.g., aerospace equipment) is not supported. When considering the use of Sanken products in applications where higher reliability is required (transportation equipment and its control systems or equipment, fire- or burglar-alarm systems, various safety devices, etc.), contact a company sales representative to discuss and obtain written confirmation of your specifications. The use of Sanken products without the written consent of Sanken in applications where extremely high reliability is required (aerospace equipment, nuclear power-control stations, life-support systems, etc.) is strictly prohibited. The information included herein is believed to be accurate and reliable. Application and operation examples described in this publication are given for reference only and Sanken assumes no responsibility for any infringement of industrial property rights, intellectual property rights, or any other rights of Sanken or any third party that may result from its use. The contents in this document must not be transcribed or copied without Sanken’s written consent. C-PD01 SANKEN ELECTRIC CO., LTD. 2 July 17, 2013