DIP Switches DX236 Series Machine Insertable Type Dip Switches ON 2 3 4 5 6 7 8 9 10 11 12 (With Tape) 1 P.C.B LAYOUT SCHEMATIC Unit: MM How to order: 1 Material: 2 3 4 5 6 DX236 S 1 TYPE OF TERMINALS: SMT Terminals 2 NO. OF POSITIONS: All specifications are restricted to QA test criteria. DRW: D.L. JIN, CHK: D.F. LEE, APP: H.Z. QIU Code Positions A (mm) 3 A N T NT 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 5 09 9 10 10 U T 12 12 4 04 10 12 20 30 6 B R [email protected] ACTUATOR & TAPE SEALING : Raised Actuator Recessed Actuator Without Tape Sealed Recessed Actuator With Tape Sealed Recessed Actuator in ON-Position with Tape Sealed GOLD PLATING: Gold 4 µ” Min. Gold 10 µ” Min. Gold 12 µ” Min. Gold 20 µ” Min. Gold 30 µ” Min. Part Name Material Plating PLATING MATERIAL: Contact Gold Plated;Terminals Gold Plated Contact Gold Plated;Terminals Tin Plated PACKAGE STYLE: Tube Tape & Reel www.greatecs.com 1 DIP Switches Machine Insertable Type Dip Switches DX236 Series SPECIFICATIONS 1.Ratings: 1.1 Mechanical Life : 3000 cycles minimum 1.2 Contact Rating: 100mA at 50 Vdc non-switching; 25 mA at 24 Vdc, 10 mA at 50 Vdc Switching. 1.3 Contact Resistance: 50 milliohms maximum (initial) 100 milliohms maximum (after test) 1.4 Insulation Resistance: 1,000Mȟ Minimum at 500 Vdc between adjacent closed contacts and Also across open switch contacts. 1.5 Dielectric Strength: 500 Vac, RMS, minimum voltage measured between adjacent closed contacts and also across open switch contacts. 1.6 Switch Capacitance: 5pF at 1 MHz 1.7 Operating Temperature:-40ɗ to +85ɗ. 1.8 Storage Temperature: -40ɗ to +85ɗ. 1.9 Test condition : The standard test shall be 5 ~ 35ɗ temperature and 45 ~ 85% relative humidity 860 ~ 1060 Hpa atmospheric pressure unless otherwise specified. In case of any question happen, retest condition shall specify by temperature 20 Ʋ 2ɗ, 65 Ʋ5%RH and 860 ~ 1060 Hpa. 2.Materials and Platings: 2.1 Plating code : U: Full Gold Plated (Contact area & Terminal with gold-plated ) T: Contact – Gold plated with Terminal Tin-plated 2.2 Plated code : 04: 4u” Gold-Plated 10: 10u” Gold-Plated 12: 12u” Gold-Plated 20: 20u” Gold-Plated 30: 30u” Gold-Plated 2.3 Base : UL 94 V0 grade PPS Thermoplastic / Black color 2.4 Cover : UL 94 V0 grade PPS Thermoplastic / Black color 2.5 Actuator : UL 94 V0 grade NYLON Thermoplastic / White color 3.Switch Operation and Taping: 3.1 3.2 Use tweezers or ball point pen for operation. Flux cleaning should be done without removing the tape 3.3 If the tape is removed, it adhered less than before when it is placed back on, possibly causing flux inflow. Sealed switches withstand aqueous, detergent and isopropyl alcohol washing. 3.4 [email protected] www.greatecs.com 2 DIP Switches Machine Insertable Type Dip Switches DX236 Series 4. ELECTRICAL CHARACTERISTIC : ITEM TEST DESCRIPTION 4.1 Contact Resistance 4.2 Insulation Resistance 4.3 Dielectric Breakdown Voltage 4.4 Switch Capacitance TEST CONDITIONS SPECIFICATION To be measure with AC Max 50 mӨ 1 KHz ±200Hz (Max 20mV, Max 50mA) or 10mA, 5V DC. To be measured with an Min 1,000MӨ insulation measuring device of 500V DC between all the terminals and between the terminals and the frame for 1 minute ±5 seconds. AC 500V (50-60Hz, 2mA No breakdown current) being applied between insulation all the adjacent terminals and between the terminal and frame for 1 minute. To be measured with frequency Max 5PF 1MHz ±10KHz Applied between adjacent terminal and circuit. 5. MECHANICAL CHARACTERISTIC : ITEM TEST DESCRIPTION 5.1 Operation Force 5.2 Terminal Strength MIL-STD-202F Method : 211A Condition : C 5.3 Operation Strength [email protected] TEST CONDITIONS Applied in the direction of operation. SPECIFICATION 1,000gf Max Measurement in made with a static load applied to the foot of the control unit in the operating direction. A static force of 500gf being applied in one direction on the tip of the terminal for 5~10seconds. One time each terminal. A load of 1Kgf is applied in the operating direction and pulling direction of the control unit for 15 seconds. No bending or deflection experienced. The terminal may be bent, but shall not break or damage the insulation material. Electrical characteristic of the above shall be assured. www.greatecs.com 3 DIP Switches Machine Insertable Type Dip Switches DX236 Series 6. RELIABILITY 6.1 Cold Resistance JIS-C5021 6.2 Dry Heat Resistance JIS-C5022 6.3 Humidity Resistance MIL-STD-202F Method : 103B Condition : C 6.4 Vibration Test MIL-STD-202F Method : 201A Condition : A [email protected] Switch for testing being kept in Contact resistance the conditions at -40 ±2к in Max 100mӨ temperature for 96 hours, and in Insulation resistance a normal ambient condition for Min 1,000 MӨ one hour, then to be measured Dielectric breakdown within one hour. voltage: AC 500V (Drops of water being taken 1 minute no away) breakdown insulation Switch for testing being kept in Operating force the conditions at 55±2к in 1,000gf Max. temperature for 96 hours, and in There shall be no a normal ambient condition for defects in appearance one hour, then to be measured or in the mechanical functions. within one hour. Switch for testing being kept in Contact resistance the conditions at 40 ± 2 к in Max 100mӨ temperature and 90~95% RH for Insulation resistance 96 hours, and in a normal Min 10MӨ ambient condition for one hour, Dielectric breakdown then measured within one hour. voltage: AC 500V 1 minute no breakdown insulation Operating force 800gf Max. The range of vibration: 10 ~ 55Hz Total width of vibration: 1.5mm The proportion of vibration: 10~55~10(Hz) approx. 1 minute The variation of the number of vibration: Logarithmic or approx. straight line The directions: 3 vertical directions including operation direction Amplitude : 0.03inch~0.06inch Duration: 2 hours each (Total 6 hours) There should be no defects in appearance or in the mechanical functions. www.greatecs.com 4 DIP Switches Machine Insertable Type Dip Switches 6.5 DX236 Series Contact resistance Max 100mȟ Insulation resistance Min 1,000 Mȟ Dielectric breakdown voltage: AC 500V 1 minute no breakdown insulation Operating force 1,000gf Max. There shall be no defects in appearance or in the mechanical functions. Shock Test MIL-STD-202F Method : 213B Condition : A 6.6 Thermal Shock After 5 cycle testing under the following conditions, the sample is allowed to stand under normal temperature and humidity conditions for 1 hour, and measurement is made within 1 hour after that. Water drops should be eliminated. Temperature cycle 85ɗ Ʋ2ɗ Contact resistance Max 100 mȟ Insulation resistance Min 1,000 Mȟ Dielectric breakdown voltage:AC 500 V 1 minute no breakdown insulation Operating force 1,000gf Max. There shall be no defects in appearance or in the mechanical functions -20ɗ Ʋ2ɗ 25ɗ Ʋ2ɗ 15 30 15 30 1 cycle 90min [email protected] www.greatecs.com 5 DIP Switches Machine Insertable Type Dip Switches ITEM TEST DESCRIPTION TEST CONDITIONS 6.7 Resistance to Soldering Reflow Soldering P.C. board terminal at Heat 245 ±5к, 3~5 second JIS-C5034 Should be operated in OFF positions when soldering Wave Soldering : Soldering temperature: 245 ±5к Immersing time: 3±0.5 second Iron Tip : 30W Iron / ceramic Tip Temp. : 320±5к / 3 sec per pin DX236 Series SPECIFICATION Contact resistance Max 50mӨ Insulation resistance Min 1,000MӨ Dielectric breakdown voltage AC500V 1 minute no breakdown insulation Operating force 1,000gf Max (1) Reflow soldering: Device :In-line or Batch system Apply reflow soldering only once (2) When soldering two or more terminals to the common land, use solder resist to solder them independently. 6.8 Salt-Spray Test MIL-STD-202F Method : 101D Condition : B [email protected] The sample is allowed to stand in the test chamber controlled to 35±2к in temperature and 5± 1% (weight ratio) salt-water concentration for 48±1hour and is subjected to test. Then, salt deposits attached to the sample are washed away with water. Shall be free from functionally harmful rust. There shall be no defects in appearance or in the mechanical functions. www.greatecs.com 6 DIP Switches Machine Insertable Type Dip Switches DX236 Series 7. DURABILITY ITEM TEST DESCRIPTION 7.1 Operation Life With No Load 7.2 Operation Life With Load TEST CONDITIONS SPECIFICATION 3,000 cycle operation at a rate Contact resistance of 15 ~20 cycle / minute Max 100 mӨ Insulation resistance Min 1,000 MӨ with DC 250V Dielectric breakdown voltage:AC 250 V 1 minute no breakdown DC 2AV 25mA 2,000 cycle insulation operation at a rate of 15 ~ 20 Operating force : 1,000gf cycle / minute Max. There shall be no defects in appearance or in the mechanical functions. [email protected] www.greatecs.com 7 DIP Switches 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 7 8 8 8 8 KE 9 10 11 12 KE 9 10 11 12 KE 9 10 11 12 KE 9 10 11 12 9 10 11 12 6 9 10 11 12 5 8 4 8 3 7 2 7 KE 6 6 9 10 11 12 KE 9 10 11 12 KE 9 10 11 12 KE KE 5 5 8 8 8 4 7 7 7 4 6 6 6 3 5 5 5 3 4 4 4 2 3 3 3 2 2 2 2 KE 9 10 11 12 6 7 7 8 8 9 10 11 12 9 10 11 12 8 6 7 5 6 5 5 4 4 4 3 3 2 3 KE 2 KE 2 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 1 ON 2 2 2 3 3 3 4 4 4 5 5 5 5 5 5 4 4 3 4 2 3 5 5 5 3 4 4 4 2 3 3 3 2 2 2 2 4 4 5 5 5 3 4 3 3 2 2 2 6 KE 6 KE 6 KE 6 KE 6 KE 6 KE 6 KE 6 KE 6 KE 6 KE 6 KE 6 KE ON 1 2 3 4 5 KE 6 ON 1 2 3 4 5 6 7 8 KE 9 10 11 12 8 www.greatecs.com [email protected] DX236 Series Machine Insertable Type Dip Switches 8. TAPE & REEL PACKAGING