F E AT U R E S MODEL NO. 100C06 1 1 D C - 4 50 MHz 50Ω or 75Ω Terminations 20 Watts CW SMA Connectors Diode Suppression of Switching Transients SP2T .08 SMA FEMALE (3 PLACES) 1.336 .08 .44 TYP .75 J2 SP 2 T Re la y .093 DIA THRU 4 HOLES J2 J3 1.50 ±.03 1.336 J3 2 1 • • J1 .28 MAX SOLDER TERMINAL (3 PLACES) • 1.50 ± .03 3 +V COM PART IDENTIFICATION .62 ± .03 VSWR I.L. (dB) ISO (dB) .22 ± .03 TYP 1.8 0.8 120 1.6 0.6 90 1.4 0.4 60 1.2 0.2 30 1.0 0 • 50 Ω 1/2 W • • J1 3 1 2 50 Ω 1/2 W .xx = .02 .xxx = .010 GUARANTEED PERFORM A NCE T YP I CA L P E R F OR MA NC E at 25 ° C ISO Parameter Min Typ Max Units Operating Frequency DC Voltage Insertion Loss DC Isolation VSWR 70 55 45 Thru Impedance Switching Speed RF Power Operate Operating Temperature -55 I. LOSS VSWR 0.1 0.3 0.5 80 65 50 1.05/1 1.15/1 1.3/1 50 +25 450 MHz 0.2 0.35 0.60 dB dB dB dB dB dB 1.15/1 1.2/1 1.4/1 5 20 +85 4 40 100 10 FREQUENCY (MHz) 400 1000 CONTROL VOLTAGE TABLE PART NO. EXAMPLE 100C0611 - 6 - F/S - R - 75 Basic Add for 75 Ω Part Number Termination. Omit for 50 Ω Termination. Dash No. for Coil Voltage (See Table). For Reverse Polarity of Diodes. Omit for “F/S” for Failsafe J1 to J2 Standard. See Schematic omit for Standard. for Standard. DA I C O In d u s t r i e s See Table DC - 50 MHz 50 - 250 MHz 250 - 450 MHz DC - 50 MHz 50 - 250 MHz 250 - 450 MHz DC - 50 MHz 50 - 250 MHz 250 - 450 MHz OHMS mSEC W CW °C TA 0 1 Conditions Voltage Current - Typical 6 12 18 26 65 mA 32 mA 21 mA 17 mA