Absolute Maximum Ratings 1/
Supply Voltage (VCC) .........................................................
Differential Input Voltage 2/...............................................
Differential Input Current 2/ ...............................................
Input Voltage ......................................................................
Output Short Circuit Duration ............................................
Storage Temperature Range................................................
Lead Temperature (soldering, 60 seconds).........................
Power Dissipation (PD) .......................................................
Maximum Junction Temperature (TJ).................................
Ambient Operating Temperature Range.............................
±18V dc
±1V dc
±25mA
Supply voltage
Continuous
-65°C to +150°C
+300°C
500mW
+150°C
-55°C to +125°C
Absolute Maximum Ratings Notes:
1/
2/
3.1
Stresses above the absolute maximum rating may cause permanent damage to
the device. Extended operation at the maximum levels may degrade
performance and affect reliability.
The inputs are protected by back-to-back diodes. Current limiting resistors are
not used in order to achieve low noise performance. If the differential input
voltage exceeds ±1V, the input current should be limited to ±25mA.
Thermal Characteristics:
Thermal Resistance, Lead Leadless Chip Carrier (TC) Package
Junction-to-Case (ΘJC) = See MIL-STD-1835
Junction-to-Ambient (ΘJA) = 110 °C/W Max
4.0
Electrical Table:
Table I - Electrical Characteristics
Parameter
Symbol
Input Offset Voltage
VIO
Conditions
1/
M, D, L, R
Input Offset Current
IIO
VCM = 0V
M, D, L, R
Input Bias Current
Input Noise Voltage 4/
IIB
En
VCM = 0V
M, D, L, R
fo = 1Hz to 100Hz
VO = ±10V, RL = 10kΩ
Large Signal Voltage Gain
AVS
M, D, L, R
VO = ±10V, RL = 2kΩ 4/
ASD0013059 Rev. B
25-Sep-07
Subgroups
1
2, 3
1
1
2, 3
1
1
2, 3
1
7
4
5, 6
4
4
5, 6
Limit
Min
1000
750
100
500
400
Limit
Max
±0.4
±0.6
±0.6
±10
±20
±50
±25
±50
±500
110
Units
mV
nA
nVRMS
V/mV
Page 2 of 5
OP470
Very low noise, quad, operational amplifier
Table I - Electrical Characteristics (continued)
Conditions
Sub1/
groups
Output Voltage Swing 4/
VOP
RL = 2Kohm
4, 5, 6,
No Load
1, 2, 3
Supply Current 2/
ISY
M, D, L, R
1
Input Voltage Range 4/
IVR
1, 2, 3
Slew Rate 4/
SR
7
AVLC = +21, RL = 10kΩ
1
Common Mode Rejection 4/ CMR
VCM = IVR 3/
2, 3
1
Power Supply Rejection
PSRR
VS = ±4.5V to ±18V
Ratio 4/
2, 3
Parameter
Symbol
Limit
Min
±12
Limit
Max
Units
V
11
11
±11
1.4
110
100
mA
V
V/μV
dB
1.8
5.6
μV/V
Table I Notes:
1/ VS = ±15V, RS = 50Ω, unless otherwise specified.
2/ ISY limit equals the total of all four amplifiers.
3/ IVR is defined as the VCM range used for the CMR test.
4/ Not tested Post Irradiation.
4.1
Electrical Test Requirements:
Table II
Subgroups (in accordance with
MIL-PRF-38535, Table III)
Test Requirements
Interim Electrical Parameters
1
Final Electrical Parameters
1, 2, 3, 4, 5, 6 1/ 2/
Group A Test Requirements
1, 2, 3, 4, 5, 6, 7
Group C end-point electrical parameters
1, 2, 3 2/
Group D end-point electrical parameters
1
Group E end-point electrical parameters
1
1/ PDA applies to Subgroup 1 only. Delta's excluded from PDA.
2/ See Table III for delta parameters. See table I for conditions.
4.2
Life Test and Burn-In Delta Limits:
Table III
TEST
TITLE
BURN-IN
ENDPOINT
LIFETEST
ENDPOINT
DELTA
LIMIT
UNITS
VIO
±0.4
±0.5
±0.1
mV
IIB
±25
±30
±5
nA
IIO
±10
±15
±5
nA
ASD0013059 Rev. B
25-Sep-07
Page 3 of 5
OP470
Very low noise, quad, operational amplifier
5.0
Life Test/Burn-In Information
5.1
5.2
5.3
HTRB is not applicable for this drawing.
Burn-in is per MIL-STD-883 Method 1015 test condition B.
Steady state life test is per MIL-STD-883 Method 1005.
ASD0013059 Rev. B
25-Sep-07
Page 4 of 5
OP470
Very low noise, quad, operational amplifier
Rev
A
B
Description of Change
Initiate
Update web address. Remove BI circuit.
ASD0013059 Rev. B
25-Sep-07
Date
Dec. 10, 2002
May 29, 2003
Page 5 of 5