280-028P

series 28
HiPer-D Standard and High-Density Connectors
280-028P right angle PC tail pin connectors with low profile
mounting flange
Low profile right angle PC tail HiPer-D pin connectors feature rugged machined
aluminum shell and stainless steel cover for improved EMI protection. Contacts
are non-removable, size #20 or #22. Intermateable with standard M24308-type
D-Subminiature connectors, the HiPer-D features a resilient face seal for environmental
protection and optional ground springs for improved resistance to electromagnetic
interference. Threaded holes on the bottom of the connector allow attachment to
circuit board. Contacts are potted with epoxy. Glass-reinforced thermoset epoxy
insulators, fluorosilicone face seal. 1000 VAC, 5 Amps (#22) or 7.5 Amps (#20).
B
Shell Size - Contact Arrangements
How To Order
280-028P
Sample Part Number
4h62
Basic Part Number
280-028P
Shell SizeContact Arrangement
Contact Arrangements are shown in the
adjacent table
Shell Finish
ME = Electroless Nickel (RoHS)
MT = Nickel-PTFE (RoHS)
JF = Cadmium with Yellow Chromate
Z2 = Gold (RoHS)
Z1 = Passivated Stainless Steel (RoHS)
Mating Hardware
PC Tail Length
n
a
Shell SizeContact Arr.
Contact Size and Qty
#20
#22
Standard Density
1S9
9
2S15
15
3S25
25
4S37
37
5S50
50
High Density
1h15
15
2H26
26
N = No Hardware (supplied with #4-40 tapped holes)
P = #4-40 Female Jackposts
3H44
44
4H62
62
A = .125 (3.18) Tail Length
B = .250 (6.35) Tail Length
5H78
78
6H104
104
Materials and Finishes
Aluminum alloy
Copper alloy, 50 microin. gold plated
Thermoset epoxy
Epoxy
Fluorosilicone rubber
300 series stainless steel
Current Rating
Test Voltage
Insulation Resistance
Operating Temperature
Ingress Protection
Shock
Vibration, Random
B-24
g
G = Supplied with EMI Ground Spring
N = No Ground Spring
Ground Spring
Shell
Contacts
Insulators
Potting Compound
Interfacial Seal
Hardware
me
Specifications
#22 5 AMPS, #20 7.5 AMPS
1000 VAC RMS
5000 megohms minimum
-65° C. to +200° C.
IP 67
300 g.
43.92 g.
Mating Hardware
N
No Hardware
#4-40 Female Threads in
Mounting Holes
Choose this option for
rear panel mounting and
order jackpost kit 289-016
separately.
© 2013 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324
P
#4-40 Female Jackposts
series 28
HiPer-D Standard and High-Density Connectors
280-028P right angle PC tail pin connectors with low profile
mounting flange
280-028p dIMENSIONS
4-40 UNC 2B TH'D
.150 (3.81) MIN. DEEP TYP 2PL
OR #4-40 JACKPOST 2PL
A
C
D
SEE PCB FOOTPRINTS
E
B
B
10°
TYP 2 PL
.318 (8.08)
STD DENSITY SIZE #20HD CONTACTS
.030±.002(0.76±0.05)
PC TAIL LENGTH HI DENSITY SIZE #22D CONTACTS
± .015 (3.81)
.020±.002(0.51±0.05)
.262±.003
(6.65±0.08)
4-40 UNC 2B TH'D
.150 (3.81) MIN. DEEP TYP 2PL
C
Shell
Size
1
2
3
4
5
6
in
A
mm
in
30.81
39.14
53.04
69.32
66.93
69.32
.494
.494
.494
.494
.605
.668
B
mm
± .015 ± 0.38 ± .015 ± 0.38
1.213
1.541
2.088
2.729
2.635
2.729
12.55
12.55
12.55
12.55
15.37
16.97
C Basic
in
D
E
mm
in
mm
18.44
26.77
40.49
56.95
54.33
57.71
.389 9.88
.389 9.88
.389 9.88
.389 9.88
.501 12.73
.563 14.30
in.
mm
± .005 ± 0.13 ± .005 ± 0.13
.984
1.312
1.852
2.500
2.406
2.500
24.99
33.32
47.04
63.50
61.11
63.50
.726
1.054
1.594
2.242
2.139
2.272
Notes
B-25
1.
Contacts are factory-installed, non-removable and are potted with epoxy.
2.
HiPer-D connectors are available with a wide variety of materials and finishes. See About Series 28 HiPer-D Shell Plating Options for
additional choices . Glenair offers the industry’s widest selection of plating and material choices with no setup charge, no minimum
order quantity and no schedule impact.
3.
For panel cutout dimensions, refer to Panel Cutouts and Printed Circuit Board Footprints.
4.
For printed circuit board mounting dimensions, refer to Panel Cutouts and Printed Circuit Board Footprints.
5.
HiPer-D connectors meet the requirements of MIL-DTL-24308 and are intermateable with standard M24308-type D-Subminiature
connectors with corresponding contact arrangements and type.
6.
Additional electrical, mechanical and environmental specifications are listed in HiPer-D Product Specification.
© 2013 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324