Installation Procedures for Sentry System

Series 72
Annular Tubing
Installation Procedures for
Sentry System
(710-840, 710-841, 710-842, 710-847, 710-848, 710-849)
Sentry System Fittings
Pre-Assembly Preparation
1.
B
2.
3.
CONDUIT
Determine overall conduit assembly length
required from connector face to connector face.
From this dimension, establish conductor length
needed for connector termination and add two
inches.
Temporarily assemble connector to fitting and
hand tighten. Establish and deduct the "X"
dimension(s) from the overall assembly length in
Step 1.
Disassemble fitting from connector. Prepare
conduit and assemble to fitting per instructions
for the fitting series used.
X
SPLIT BUSHING
CONNECTOR
REF.
COUPLING NUT
FITTING BODY
COMPRESSION NUT
Fitting/Conduit Assembly
1. Cut the conduit to length plus 0.5 inch (12.7 mm) per pre-assembly preparation step 2 using conduit shears or an equivalent.
Using the “split bushing” as a guide, trim conduit perpendicular to the bore.
2. Remove bushing and slide compression nut on
conduit.
3. Reinstall bushing and bring nut forward.
4. Thread nut into rear of fitting body and bottom on
shoulder. Torque to 35 to 50 inch pounds.
Glenair 600 series backshell assembly tools are recommended for assembly and installation.