S3 Series Control Panel Description Small Addressable Fire Alarm Control Panel The Gamewell-FCI, S3 Series Intelligent Fire Alarm Control Panel provides the latest innovative high-end processing power. The S3 Series is a digital, microprocessor-based system that offers a simple, intuitive solution for the small to mid-sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports either of the following types of networks. • Up to 64 nodes using the 7100 Series panel. • Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted-pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ethernet connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. The basic S3 Series consists of an SLP (Smart Loop Panel) main board, LCD-SLP touchscreen display, SLC loop personality modules, and 7 amp power supply. The SLP provides either one or two SLC loops in Class A or B configuration that supports either of the following protocols: • Up to 318 devices per loop using the System Sensor® protocol. If you add a second loop module, it increases the maximum device count to 636 devices. • Up to 126 devices per loop using the Apollo protocol. If you add a second loop module, it increases the maximum device count to 252 devices. Four Class B or two Class A NACs can be wired and synchronized using the System Sensor, Cooper-Wheelock, or Gentex strobes. To retrofit the SLP on the existing audible/ visual appliances, the on-board Electronic EOL (EEOL) automatically adjusts to the EOL resistor in the field. A 4.3" (10.92 cm) color touchscreen display screen shows the following: • Events on the system • Status of analog addressable devices • Complete diagnostic fault codes/messages • Five programmable function buttons with LED status for accessibility to the following functions: - Disable/Enable - Trouble Acknowledge - Bypass Output - Alarm Acknowledge - Lamp Test - Custom-defined S3 Series Features • Listed per ANSI/UL® Standard 864 9th Edition. • IBC Seismic Certified. • Allows one SLC loop (expandable to two loops) that supports either System Sensor or Apollo devices in Class A or Class B (Style 4, 6 or 7). • System Sensor supports up to 318 intelligent devices and each SLC loop supports the following. - up to 159 detectors. - up to 159 modules (expandable to 636 maximum per panel). • Apollo supports up to 126 intelligent detectors and modules per SLC. (Expandable to 252 maximum per panel). • Includes a high resolution (4.3”) (10.92 cm) color touchscreen display. • Supports a network system of up to 122 nodes (includes E3 Series® panels) or up to 64 nodes (includes 7100 Series). • Provides 7.0 amp power supply (120VAC or 240VAC). • Includes four Class B or two Class A built-in Notification Appliance Circuits (NAC). Provides selectable System Sensor, Cooper-Wheelock, or Gentex strobe synchronization. • Supports up to 32 serial annunciators (LCD, LED-only, LED Switch). SIGNALING ® ® ® E3 Series , System Sensor and FocalPoint are registered trademarks of Honeywell International Inc. ® UL is a registered trademark of Underwriters Laboratories Inc. FM S1869 APPROVED City of Chicago Approved FDNY: COA-#6162 7165-1703:0176 Class 1 Reference Certificate MEA of Compliance VMA-45894-02C GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60730 Rev. F1 page 1 of 4 ©2015 by Honeywell International Inc. All rights reserved. Application The S3 Series Fire Alarm and Life Safety System is an easy-to-use intelligent fire alarm solution designed for the small to mid-sized buildings. Analog technology delivers the benefits of a simple system installation, while a userfriendly interface makes panel operation and system maintenance quick and intuitive. Smart Panel Programming Using Boolean logic programming, the installer may customize the system to precisely suit the needs of the building owner. Auto-programming allows the installer to instantly locate all the devices on the SLC loop. Simple, Intuitive Display The front panel display provides a user-friendly interface for the operator's control. A 4.3” (10.922 cm) color touchscreen displays system status, event details and service modes. On the front of the panel, six LEDs show the following conditions. • Fire • Silenced • Hazard (Gas or CO) • AC Power • Supervisory • Trouble Five custom programmable switches allow the user quick access to common functions specific to the building like device disable, output bypass and device status. Perfect for Retrofits The S3 Series is well-suited for retrofit applications. The SLP provides a simple way to upgrade your fire protection system. It is designed to be an upgrade solution for the legacy FCI 7100 and Gamewell 602 Series panels. An added feature is the SLP's EEOL. Using EEOL, the installers can automatically identify the EOL for existing audible/visual appliances. Flexibility for Future Growth The S3 Series can be expanded to add a second SLC loop without replacing the entire system. Using the RPT-E3UTP Network Repeater, you can network up to 64 nodes (122 nodes with the ANX node expander) using either twisted-pair or fiber-optic. The built-in Ethernet port allows the connection to the Gamewell-FCI’s FocalPoint Graphical Workstation. Figure 1 LCD-SLP Display Features (Continued) • Offers an Ethernet port for programming, a variety of system reports, and a FocalPoint® Graphic Workstation connectivity. • Provides two fully-programmable Form-C contacts for Fire, Trouble, and Supervisory. • TimeCap - Saves time and date up to 48 hours without any power or battery. • Automatically adjusts to any NAC End-of-Line Resistor (EOL) value (1k-55k ohm) for legacy audible/visual appliances. • Removable display can be used as a remote annunciator. • Suitable for pre-action deluge applications. Optional Accessories DACT-E3 - Dialer The Digital Alarm Communication Transmitter sends digital signals over telephone lines to the central station. It connects to the SLP through an RS-485 bus. Using the Contact ID format, the DACT-E3 provides a four-digit account code followed by the code/numbers listed below: • Three-digit Event Code • Two-digit Group Number • Three-digit Contact Number All codes are used to provide specific point identification. The DACT-E3 is compatible with digital alarm communicator receivers (DACRs) that receive the following signaling formats: • Contact ID • SIA • 3+1 • 4+2 For more information, refer to the following data sheets: DACT-E3 Data Sheet, P/N: 9020-0610 FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 RPT-E3-UTP - Network Repeater Card The Network Repeater allows the SLP fire control panels to connect to the broadband network from remote locations. It connects to other networked units using unshielded, twisted-pair wiring. The RPT-E3-UTP is available with two add-on fiber modules: • FML-E3 connects to the network using either 62.5/125 micron multi-mode fiber. • FSL-E3 connects to the network using 9/125 micron single-mode fiber. Refer to the RPT-E3-UTP Data Sheet, P/N: 9020-0609. LCD-7100 - Remote Annunciator The Remote serial display features an 80-character display. The LCD-7100 can be surface or flush-mounted on a standard 4-gang electrical box. You can use up to five LCD-7100 remote annunciators per SLP panel. For more information, refer to the LCD-7100 Data Sheet, P/N: 9020-0486. ASM-16 - Addressable Switch/LED Module There are 16 programmable switches available to perform any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g. ON, OFF, Activated, etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N: 9020-0554. ANU-48 - 48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located UL® Listed annunciator enclosure. Up to 16 ANU-48 modules can be connected to the SLP panel. For more information, refer to the ANU-48 Data Sheet, P/N: 9020-0596. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60730 Rev. F1 page 2 of 4 www.gamewell-fci.com Specifications Figure 2 illustrates the SLP-BB Cabinet Enclosure. Device Loops SLP-BB CABINET BACKBOX 14 1/2 "W SLP-BB CABINET OUTER DOOR NAC circuits 4 NAC Operating Voltage NAC Minimum Voltage SLC Loop Circuit Operating Voltage Input Voltage 3 2 Up to two Class A or B, System Sensor units, each loop supporting up to 318 device addresses. OrApollo units, each loop supporting up to 126 device addresses per loop. 4 Class B or 2 Class A (2.0 A each circuit), 6.0 A total 24 VDC 19.5 VDC @ 20.4 V battery voltage 24 V peak-to-peak 120 VAC, 60 Hz 240 VAC 50-60 Hz Input Current 120 VAC, 2.75 amps max. 240 VAC, 1.4 amps max. Aux Power 1 (Continuous) 24 VDC nominal at 1.0A Aux Power 2 (Resettable) 24 VDC nominal at 1.0A Base Panel Current draw Standby: 0.111 amps Alarm: 0.243 amps Operating Temperature 32°-120° F (0°-49° C) Relative Humidity 93% (non-condensing) Battery Charger Voltage +24 VDC Battery Charger 55 A/H batteries (cabinet Capacity accommodates 12 A/H batteries) Alarm, Trouble & Supervisory Relay Contacts Form-C, 2 amps @ 24VDC (resistive) 20 1/8"H 1 4 1/2" D Cabinet Dimensions: SLP-BB Dimensions Figure 2 SLP Enclosure S3BB-RB Dimensions Supports up to 636 Velociti devices or 252 XP95 devices DNR Networkable up to 122 panels using twisted pair wire or fiber optics. MCS-COF Fire/Carbon Monoxide Detector ASD-PL2F ASD-LS Photo Detector Laser Detector AMM-2IF AMM-2RIF Mini Monitor Module Dual Input/Output Module LCD-E3 Remote Annunicator RS232 LCD-SLP Color Touchscreen Annunicator DACT Pull Station Relay: 3 Form C MS-7AF Relay Module Local Energy Trip RS485 AOM-2RF LCD-7100 S3 Series Fire Alarm Control Panel Intelligent Duct Detector emote Annunicator 14 1/2” W x 20 1/8” H x 4 1/2” D (36.83 W x 51.18 H x 11.43 D cm) 19 3/8” W x 19 3/8” H x 4.5” D (49.22 W x 49.22 H x 11.43 D) E3 Series Panel Ethernet FocalPoint Workstation ASM-16 ANU-48 LED Switch Control LED Display Driver Laptop Programming Figure 3 SLP Panel Configuration GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60730 Rev. F1 page 3 of 4 Ordering Information Ordering Information (Continued) Part Number Description Description SLP-BLK SLP addressable FACP in black SLP-BB enclosure. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLP addressable FACP with red door and black SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLP addressable FACP 240VAC power supply with red door and black SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. System Sensor Loop Card - 1 loop used for 159 sensors and 159 modules. For use with the SLP-E3 panels only. Apollo Loop Card-1 loop used for 126 sensors and modules. For use with the SLP-E3 panels only. Part Number Accessories DACT-E3 Digital Dialer Communicator Transmitter for the S3 or E3 Series. LCD Color Touchscreen display with five programmable switches. For use with the S3 Series panels. Remote annunciation requires the E3 Series A2 cabinet. (E3BB-BA2, E3BB-RA2) Network repeater card with twistedpair fiber connections require either an FML-E3 or an FSL-E3 card. Multi-mode fiber-optic card for one channel on the RPT-E3-UTP. Single-mode fiber-optic card for one channel on the RPT-E3-UTP. SLP motherboard For use with the replacement or the retrofit solutions. SLP 120VAC 7A power supply. For use with the replacement or the retrofit solutions. SLP Retrofit Kit for the 7100 B-Slim and IF602 panels. Includes the new door and the mounting plate. Requires the following: • SLP-RB • LCD-SLP • SLC-PM/ • FLPS-7-RB SLC95-PM SLP red cabinet with an inner door for the mounting display behind the plexiglass. Requires the following: • SLP-RB • LCD-SLP • SLC-PM/ • FLPS-7-RB SLC95-PM Remote Serial LCD Annunciator Remote Programmable Addressable Switch/LED Module Remote LED Driver Module SLP-RED SLP-RED-G SLC-PM SLC95-PM LCD-SLP RPT-E3-UTP FML-E3 FSL-E3 SLP-RB FLPS-7-RB SLP-RETROFIT S3BB-RB LCD-7100 ASM-16 ANU-48 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60730 Rev. F1 page 4 of 4 www.gamewell-fci.com