Velociti® Series AMM-2RIF Description Addressable Input/Output Module The Gamewell-FCI Velociti Series multi-function module (AMM-2RIF) combines two relay outputs and two monitor inputs into one device. The module is capable of Class B supervised wiring that is used for the monitored devices. It also contains Form C relay contacts which allow the panel to switch the contacts on command. There is a dedicated LED on the module for each input and output. The control panel can use these bi-color LEDS to indicate normal, alarm and trouble conditions. This module is ideally suited for areas where inputs and outputs are needed in the same location. It could be used to function with any of the following devices: • smoke/fire dampers • security doors • HVAC fan • dedicated smoke control • non-dedicated smoke fan By combining two (2) relay outputs and two (2) monitor inputs into one device, you can save the cost of installing four (4) devices. This feature can be beneficial when you need to install these devices in high rise buildings or large shopping complexes. The two input/two output module is the same size module as the standard single modules. It can mount directly to a 4-inch (10.16 cm) square electrical box, the surface mounted SMB500, or into a DNR(W) duct housing. Relay Contact Ratings Current Maximum Load Rating Voltage Description Application 2A 25 VAC PF = 0.35 Non-coded 3A 30 VDC Resistive Non-coded 2A 30 VDC Resistive Coded 0.46 A 30 VDC Inductive (L/R - 20ms) Non-coded 0.7 A 70.7 VAC PF = 0.35 Non-coded 0.9 A 125 VDC Resistive Non-coded 0.5 A 125 VDC PF = 0.75 Non-coded 0.3 A 125 VDC PF = 0.35 Non-coded AMM-2RIF Features • • • • • • Velociti® and E3 Series® are registered trademarks of Honeywell International Inc. Provides two (2) relay outputs and two (2) monitor inputs in one space-saving module Offers visual rotary, decimal switch addressing (01-159) Contains the following: - Two (2) sets of Class B initiating device circuits - Two (2) sets of Form C relay contacts Uses bicolor LEDs for each input and output flash, when addressed, and lights steady when in alarm Includes a Dip switch to manually disable one (1) input and one (1) output Ideal for fan, smoke control, and door entry installations SIGNALING S1949 7300-1703-0174 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60709 Rev. B page 1 of 2 ©2013 Honeywell International Inc. All rights reserved. Description (Continued) Specifications Use rotary switches to set the address setting. You can set the base via the rotary switch and assign the address to Relay Output #1 from Address 00 to Address 156. The module automatically assigns the next three addresses as appropriate to Monitored Input #1, Relay Output #2, and Monitored Input #2. If the Relay Output #2 or the Monitored Input #2 are not used, use the DIP switch to manually disable those addresses. You can use Relay Output #2 and the Monitored Input #2 addresses for other devices on the loop. Supervisory Current: Alarm Current: Operating Temperature: Relative Humidity: Figure 1 illustrates the Address Disable Switch. 0.00130 A 0.024 A 32°F to 120°F (0°C to 49°C) 10% to 93% (Non-condensing) Temperature Rating: 32°F to 120°F (0°C to 49°C) Dimensions: 4 1/2” H x 4” W x 1 1/4” D (11 H x 10.2 W c 3.2 D cm) End-of-Line Resistor: 47k Ohms Ordering Information Part Number Description AMM-2RIF Addressable 2 Input/2 Output Module Figure 1 Address Disable Switch GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60709 Rev. B page 2 of 2 www.gamewell-fci.com