Analyzers - Keysight

2011 Agilent RF/uW Symposium
New Instruments and Software for
RF/uW Applications
Presented by: Giuseppe Savoia, Agilent Technologies
Copyright © 2011 Agilent Technologies
Objectives
• Introduce new instruments and software applicable for RF/uW
applications
• Highlight key specifications and capabilities
2
Copyright © 2011 Agilent Technologies
Network Analyzers
N5247A PNA-X Network Analyzer
N5227A PNA Network Analyzer
• Now available to 67 GHz, with frequency extender options to 110 GHz
and 1.05 THz
• 2- or 4-port
www.agilent.com/find/NA
3
Copyright © 2011 Agilent Technologies
Analyzers: Vector Signal Analyzers, Signal/Spectrum
Analyzers and Oscilloscopes
89601B Vector Signal Analysis Software (major revision)
• Runs on Signal/Spectrum Analyzers, Scopes, Logic Analyzers, on PC
or in the instrument
• Flexible OFDM analysis capability allows analysis of many new waveforms
• Over 70 Signal standards and modulation types
• Spectrum, time and modulation domains
• Up to four simultaneous channels
• Ties with simulation tools (ADS, SystemVue) and MATLAB ®
www.agilent.com/find/vsa
4
Copyright © 2011 Agilent Technologies
8 9 6 0 0 B V E C T O R S I G N A L A N A LY S I S S O F T W A R E
Premier frequency, time & modulation
analysis for Wireless R&D
Supports > 70 signal formats
• GSM to WiFi, WiMAX & LTE
• 2FSK to 1024QAM
• AM/FM/PM
• SISO and MIMO (4x4)
• Custom OFDM
High resolution (409K line) FFT based spectrum
High quality time measurements
Copyright © 2011 Agilent Technologies
8 9 6 0 0 B V E C T O R S I G N A L A N A LY S I S S O F T W A R E
20:20 Flexible GUI
• 20 traces with 20 markers each
• Arbitrary arrangement, size &
measurement assignment
• Advanced trace types: Spectrogram,
Cumulative History, Digital Persistence
• SCPI programming
Copyright © 2011 Agilent Technologies
Analyzers: Vector Signal Analyzers, Signal/Spectrum
Analyzers and Oscilloscopes
M9392A PXI Vector Signal Analyzer
•
•
•
•
To 26.5 GHz
250 MHz bandwidth, 2 GS/s sample rate
Flexible configuration
PXIe modular format
www.agilent.com/find/M9392A
7
Copyright © 2011 Agilent Technologies
Analyzers: Vector Signal Analyzers, Signal/Spectrum
Analyzers and Oscilloscopes
Infiniium 90000-X Series Oscilloscopes
•
•
•
•
•
Up to 32 GHz true analog bandwidth
80 GSa/s sample rate (2 channels)
2- or 4-channels
Up to 2 Gpoints memory depth
Lowest noise floor and jitter measurement floor available
www.agilent.com/find/scope
8
Copyright © 2011 Agilent Technologies
Analyzers: Vector Signal Analyzers, Signal/Spectrum
Analyzers and Oscilloscopes
N9030A PXA Signal Analyzer
•
•
•
•
•
To 50 GHz, external mixers for higher frequencies
To 140 MHz analysis bandwidth
-172 dBm DANL
+/- 0.19 dB absolute amplitude accuracy
+22 dBm third order intercept
MXA and EXA Signal Analyzers
• New 40 MHz analysis bandwidth option
• Up to 500 MHz BW IF output above 3.6 GHz via optional wideband
IF output port
www.agilent.com/find/PXA
10
Copyright © 2011 Agilent Technologies
Agilent PXA External Mixing:
Analyze Signals to 750 GHz
Legacy Mixers
NEW
Smart Mixers
Third Party Mixers
11970 Series
millimeter mixers
18 GHz to 110 GHz
Copyright © 2011 Agilent Technologies
New M1970 V/W
50-110 GHz
≥ 110 GHz
M1970V/W
WAVEGUIDE
HARMONIC
MIXERS MIXERS
M1970V/W
WAVEGUIDE
HARMONIC
New Mixer Family
Go smart with your mixer measurements!
• M1970V option 001 (50-75 GHz)
• M1970V option 002 band (50-80 GHz)
• M1970W (75-110 GHz)
Waveguide
input
Mixer Smart Features
• USB plug and play
• Auto-transfer of conversion loss data
• Auto LO power adjust to compensate for
cable loss (better amplitude accuracy)
• Auto detect mixer model/serial number to:
•
•
•
Improved DANL and TOI
•
•
LO/IF SMA
connector
Set default frequency range
Apply LO cal data if previously connected
Prompt user to run cal if needed
• Periodic polling to assure LO is connected
• Single coax IF/LO interface
•
USB
connector
Using higher LO frequency, better conversion loss
(10 dB better than 11970x)
Lower harmonic mixing x6 for V-band and x8 for W-band
Excellent amplitude accuracy, +/- 1.5 dB
Copyright © 2011 Agilent Technologies
Orderable in April
Shipment later this year
M1970V option 001
M1970V option 002
M1970W
Analyzers: Vector Signal Analyzers, Signal/Spectrum
Analyzers
N9051A Pulse Measurement Software
• A comprehensive suite of pulse measurements as well as statistics over
time: Period, width, PRI, PRF, Droop, Overshoot, Rise time, peak and
average power plus PDF, CDF and CCDF stats and more
New options:
• Phase and frequency measurements
• Phase information, chirp measurements, pulse compression ratio,
peak sidelobe level
• Extended analysis and statistics
•Mean, max, min, std deviation, RMS, trend and autocorrelation
•Plots and histograms of data values
www.agilent.com/find/N9051A
13
Copyright © 2011 Agilent Technologies
Signal Generation Solutions
E8267D PSG Vector Signal Generator (new option):
• Low phase noise option UNY: typical 1 GHz phase noise of
-146 dBc/HZ at 10 kHz offset
E8257D PSG Analog Signal Generator (new options):
• Option 521: +24 to +28 dBm 250 MHz to 20 GHz, 27 to 33 dBm typical
output power (> 1 GHz)
• Low phase noise option UNY: available on analog and vector models
www.agilent.com/find/psg
14
Copyright © 2011 Agilent Technologies
Signal Generation Software
N7620A Signal Studio for Pulse Building Software
• New release – May price list
• New option with:
• Antenna Scan Patterns
• Variable PRI (based on entered function)
• Import .CSV files to build pulse parameters
www.agilent.com/find/N7620A
15
Copyright © 2011 Agilent Technologies
Signal Generation Solutions
M8190A Arbitrary Waveform Generator
•
•
•
•
•
14 bit up to 8 GSa/s, 12 bit up to 12 GSa/s
SFDR (prelim): - 80 dBc typical
Harmonic distortion (prelim): -75 dBc typical
Digital IF up to 4.5 GHz
I/Q generation with bandwidth up to 9 GHz – limiting factor
is now I/Q upconversion
81180A Arbitrary Waveform Generator
• 4.2 GSa/s, 12 bit arbitrary waveforms and function generator
• 1 or 2 channels (coupled and phase coherent/uncoupled)
• 2 GHz IQ modulation bandwidth
www.agilent.com/find/awg
16
Copyright © 2011 Agilent Technologies
SystemVue Base Platform Upgrades:
– New 89601B VSA models
• Use it for design, troubleshooting or connection to your Signal/Spectrum
Analyzers, Scopes, Logic Analyzers…
– Fast signal creation for Custom/Flex OFDM
• Single GUI for easy waveform creation
• Easily pass parameters to the 89601B for analysis
• Run BER or system tests
VSA
www.agilent.com/find/SystemVue
17
Copyright © 2011 Agilent Technologies
New Counters
53230A Universal Frequency Counter/Timer
•
•
•
•
•
350 MHz
Optional 6 or 15 GHz input
12 digits/sec
20 ps time interval
Pulsed RF measurements
www.agilent.com/find/counter
19
Copyright © 2011 Agilent Technologies
EMI Receiver
N9038A MXE EMI Receiver
• CISPR 16-1-1 compliance
• Integrated, single box with built-in cal source, preamp
and input protection
• Ports for conducted and radiated emissions
• 20 Hz to 3.6 GHz Radiated
• 20 Hz to 1 GHz for Conducted
• Limits and corrections built-in
www.agilent.com/find/emi
20
Copyright © 2011 Agilent Technologies
Microwave Handheld Spectrum Analyzer (HSA)
N9344C: 1 MHz to 20 GHz
N9343C: 1 MHz to 13.6 GHz
Options:
• Built-in GPS receiver and antenna (option GPS)
• Built-in tracking generator (Option TG7)
• Time-gated spectrum analysis (option TMG)
• AM/FM modulation analysis (option AMA)
Features:
• Best-in-class DANL: -155 dBm/Hz
• Fastest sweep: < 0.9 s for 20 GHz span
• High accuracy power measurement with
Agilent U2000 series USB power sensor
• Spectrum monitoring and interference
analyzing
• Security erase of data memory
Power Suite – Standard Feature
21
Copyright © 2011 Agilent Technologies
Agilent Peak Power Analyzer 8990B
Key
Applications
Radar pulse analysis
Wireless standard/ non-standard
pulse measurement
Launch Date: June , 2011
Key Specifications
Key Features
Frequency Range: 50MHz to 40GHz (sensor dependent)
 15” XGA Color Display + Touch Screen
System Rise / Fall Time: 5nsec (-20 to +20 dBm)
 4 channels (Two RF and two Analog)
Video BW: 30MHz (single shot)
150MHz (repetitive)
Dynamic Range: -35 to +20 dBm (CW)
-25 to +20 dBm (Pulse)
Sampling Rate: 100 MSa/sec
Copyright © 2011 Agilent Technologies
 Internal Zero and Calibration
 Dual Screen Zoom Window
 15 Pulse Characterization
Measurements
 Automatic pulse delay measurement
between channels
For More Information
Aerospace/Defense application areas
•
•
•
•
•
•
www.agilent.com/find/AD
www.agilent.com/find/radar
www.agilent.com/find/satellite
www.agilent.com/find/militarycomms
www.agilent.com/find/surveillance
www.agilent.com/find/techrefresh
Product information
•
•
•
•
•
•
•
•
•
www.agilent.com/find/SA
www.agilent.com/find/NA
www.agilent.com/find/SS
www.agilent.com/find/scope
www.agilent.com/find/counter
www.agilent.com/find/vsa
www.agilent.com/find/systemvue
www.agilent.com/find/modular
www.agilent.com/find/awg
23