Guideline for CIS

Guideline for CIS
[ Wafer handling]
Quality Assurance
Guideline for CIS wafer handling
1. Dress code
Carbon sealed
bunny suit
Breath mask
Carbon sealed
one-piece
ESD shielding
Latex glove
Conductive
bunny shoes
<10 class>
<100 class>
[1]
Guideline for CIS wafer handling
- Glove
入室 者
入室 者
- Head cap
[2]
Guideline for CIS wafer handling
- Mask & Dust free cap
- Conductive bunny shoes
[3]
Guideline for CIS wafer handling
2. Entrance process
- ESD Check
- Smock Check
[4]
Guideline for CIS wafer handling
- Air shower
(1) Head
(2) Shoulder
(3) Pit
(4) Chest
(5) Leg
(6) Spin
[5]
Guideline for CIS wafer handling
- Washing hands
[6]
Guideline for CIS wafer handling
3. Regulations of control temperature and humidity
Working area
Temp.(ºC)
Humidity(%)
ACT
STOP
ACT
STOP
Store room
Die room
IQA
20~27
18~29
42~68
40~70
10 Class
100 Class
1000 Class
21~27
19~29
42~58
40~60
Packing
17~27
14~30
42~58
40~60
4. Control procedure of sticky mat
-Replacement frequency : 3times/day or in case of contamination
[7]
Frequency
3times/day
Guideline for CIS wafer handling
5. Example of wafer scratch and Jig for preventing wafer scratch
- Example of wafer scratch
 Scratch occurred on the 11 o’clock direction and that is caused when take out wafer from Monsanto box
[8]
Guideline for CIS wafer handling
- Reappearance experiment of wafer scratch
. Scratch type without Monsanto packing Jig
 Due to absent of side guide, scratch can be occurred by improper wafer handling as below picture.
[Type 1]
[Type 2]
[Type 3]
[9]
Guideline for CIS wafer handling
. Scratch type without wafer cassette Jig
 Due to absent of side guide, scratch can be occurred by improper wafer handling as below picture.
[Type 1]
[Type 2]
[ 10 ]
Guideline for CIS wafer handling
- Scratch prevention JIG concept
. Adjust total height higher by using JIG, prevent interference between wafers when take/insert wafer from/to Monsanto box.
 In case of using scratch prevention Jig, even if ring frame bended, wafer does not contact each other.
[ 11 ]
Guideline for CIS wafer handling
※ Wafer cassette JIG usage during SK hynix process
Photo
Process applied
Wafer
IQA
Lamination
B/G
SAW
D/T
AVI
MONSANTO PACK
Wafer scratch prevention JIG when handling wafer in line.
BOX PACK
[ 12 ]
Guideline for CIS wafer handling
※ Monsanto Packing JIG usage during SK hynix process
Photo
Process applied
Wafer
IQA
Lamination
B/G
SAW
D/T
AVI
MONSANTO PACK
Wafer scratch prevention JIG when packing Monsanto box.
[ 13 ]
BOX PACK
Guideline for CIS wafer handling
※ Guide jig drawing
[ 14 ]
Guideline for CIS wafer handling
[ 15 ]
Guideline for CIS wafer handling
6. Wafer Storage Method and Period Guide
- Purpose
. To keep quality maximum allowable wafer shelf-hold time after vacuum-packing in the good store
- Wafer storage period
Item
Customer shelf-hold time
Maximum shelf hold time
6 months
※ shelf hold time : from wafer shipping date in SK Hynix to assembly date in customer site.
※ Vacuum-packing unopened condition. / Un-packed Wafer has to be used within 48hrs.
- Wafer storage condition
. Humidity and temperature should be maintained below storage condition
Wafer Storage Condition
Temperature
Humidity
N2 Flow Rate
FGS (Vacuum packing)
17~29℃
30~70%
-
N2 Box (Unpacked Vacuum bag)
< 28℃
< 40%
Min 11.8 ℓ/min(25scfh)
[ 16 ]