® P25 Conventional MASTR III Station VHF, UHF, 800 MHz The MASTR III P25 digital Base Station provides Secure digital communications for mission-critical applications Capability for both conventional Project 25 digital communications and conventional analog communications Capability of delivering Internet Protocol (IP) data and voice to a Harris P25IP network The MASTR III P25 provides the flexibility to commission a base station that will meet critical communication needs today and into the future. Whether users are designing a conventional Project 25 system, a conventional VHF system, or an IP-based P25 network, the MASTR III P25 keeps pace with their needs. Flexible, Efficient P25 Design The MASTR III P25 incorporates P25 digital voice and data using a digital signal processor modem for maximum design flexibility. The station can be configured for P25 mode, and can communicate with the user’s current analog dispatch network through a 4wire audio port. The P25 digital voice is translated through an onboard voice encoder/decoder in the station to allow immediate access to P25 communications through the user’s existing network. Public Safety and Professional Communications | www.pspc.harris.com 221 Jefferson Ridge Parkway | Lynchburg, VA USA 24501 | 1-800-368-3277 (+1-434-455-6403) Harris, assuredcommunications, and MASTR are registered trademarks of Harris Corporation. Copyright 2012 Harris Corporation. All rights reserved. Printed in U.S.A. 11/12 ECR-7342J The MASTR III P25 can also be configured for normal conventional analog operation at sites where P25 currently is not in use. P25IP Network As network needs expand, the MASTR III P25 is ready to grow to meet the communication requirements of the 21st century. The MASTR III P25 and a SitePro Controller enable IP voice and data packets to be sent over a Harris P25IP network and be received at the base station. This setup enables all of the advantages of IP: Seamless integration of offthe-shelf IP data applications. Easy interconnection of peripherals and ancillary equipment such as mobile data terminals, printers, scanners, and video devices for user organizations. Economical routing and backhaul of network data. Redundancy benefit of distributed IP architecture, one of the key requirements for most public safety users. Programmable Flexibility PC programmable options provide flexibility, simplified setup, and easy field upgrades. The fully synthesized design of the MASTR III P25 base station allows the user to make frequency changes quickly, easily, and affordably. The modular design of the base station makes maintenance and servicing simple and fast. Technical specifications are subject to change without notice. Product sales are subject to applicable U.S. export control laws. Conventional Options and Accessories General Specifications Conventional Tone and DC Remote Controlled Stations Programmable Options Transmit Frequencies Receive Frequencies Channel Guard Digital and Tone Channel Guard Disable Repeater Disable Intercom Function DTMF Decode Morse Code ID Squelch Tail Elimination (STE) Carrier Control Timer Station Control DC Control Tone Control Repeater DC/Repeat Tone/Repeat 4-Wire Audio Scan Additional Options Service Microphone Antenna Multicoupler 230V Power Supply Duplexer Antenna Relay Combiner Isolator Squelch-Operated Relay Remote Controllers Battery Standby Battery Charger Gel Cell Battery Switchable Channel Spacing Audio (Line to Transmitter) Line Terminating Impedance: Line Level (Adjustable): Frequency Response: Tone Control Function Tones: Secur-it Tone and Transmit Tone: Transmitted 2175 Hz Tone Level: Permissible Control Line Loss @ 2175 Hz: Audio (Receiver to Line) Audio Amplifier Input Impedance: Input Level: Output Impedance to Line: Output Level to Line Voice (1 kHz ref): Tone (1 kHz ref): Frequency Response: Hum and Noise, Noise Squelch: Tone Squelch: DC Control Control Currents: Line Loop Resistance (maximum): Power Output (Adjustable) (W) 10-110 10-110 10-110 10-100 10-100 10-100 FCC Type Acceptance Number OWDTR-0048-E OWDTR-0050-E NA OWDTR-0038-E OWDTR-0039-E OWDTR-0036-E INDOOR CABINET (Floor Mount) 69 inches 83 inches CABINET Size [in. (cm)] Height Width Depth 600 -20 to +7 dBm ±3 dB @ 300-3000 Hz 69.1 (175) 23.1 (59) 21.0 (53) Weight (min) [(lb (kg)] Continuous Duty Packed, Domestic Shipping 650, 750, 850, and 950 for P25 only 1050, 1150, 1250, 1350, 1450, 1550, 1650, 1750, 1850, 1950, and 2050 Hz 576 (261) 606 (275) Service Speaker: 1W @ 8 Service Microphone: Transistorized Dynamic Duty Cycle (EIA) Continuous: Ambient Temperature (or full spec performance per EIA): Transmit/Receive - 100% Humidity (EIA): Input Power Source: Optional Input Power Source: Standby Battery Source: Antenna Connections: Length of AC Power Cable: Metering: Altitude: 693 (315) 729 (331) Number of Rack Units 33 41 Max. Units w/Power Supply 4 5 NOTE: One rack unit equals 1.75 inches. Stations occupy 6 rack units of cabinet space. Operable: Shippable: -22 to +140oF (-30 to +60oC)* 90% @ 122oF (50oC) 120 VAC (±20%), 47-63 Hz 230 VAC (±15%), 47-63 Hz 26.4 VDC, 50 AH (min.) Type N 10 ft (3048 mm) Provided through Handset or TQ0619 Software Up to 15,000 ft (4,570 m) Up to 50,000 ft (15,250 m) *Standard network equipment for P25IP and EDACS IP configurations (0-40oC). Expanded temperature range equipment is available on request. 20 dB Below Voice Source Power Drain VHF Analog Frequency Range (MHz) 30 dB AC Input Power 10 K 1 V RMS (for 5 kHz Deviation) 600 +7 dBm (Adjustable) +7 dBm (Reference 7 dBm) +1 and -3 dB @ 300-3000 Hz -55 dB (Reference 7 dBm) -30 dB (Reference 7 dBm) -2.5, ±6, and ±11 mA 11 K (Includes 3K Termination) DC Input Power (A) Tx (full/half) Power Rx Power Tx (full/half) Power Rx Power VDC 13.8 13.8 26.4 26.4 VHF P25 Digital UHF Analog UHF P25 Digital 800 MHz Analog 800 MHz P25 Digital 851-870 TX, 806-825 RX 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 851-870 TX, 806-825 RX 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 136-174 136-174 380-512 380-512 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 Transmitter (As applicable, analog specifications measured per TIA/EIA-603 Procedure and P25 digital per TIA-102.CAAA-A) VHF Analog VHF P25 Digital UHF Analog UHF P25 Digital 800 MHz Analog 800 MHz P25 Digital Frequency Range (MHz) Rated Power Output (W) RF Output Impedance () Conducted Spurious and Harmonic Emission Frequency Stability (ppm) 136-174 110 50 136-174 110 50 380-512 100 50 380-512 100 50 851-870 100 50 851-870 100 50 -36 dBm ±1.0 -70 dBc ±1.0 -36 dBm ±1.0 -70 dBc ±0.5 (CAAB 3.2.2) external frequency std -36 dBm ±1.0 -70 dBc ±0.15 external frequency std Modulation Deviation (kHz) Wideband Narrowband 0 to ±5 0 to ±2.5 NA 2.83 kHz nominal per TIA 102 CAAB NA 0 to ±5 0 to ±2.5 NA 2.83 kHz nominal per TIA 102 CAAB NA 0 to ±5 NA NA 12.5 1.25 1.5 Tx mask 47CFR90.210d Mod fidelity <5% -55 12.5/25 1.25 2 Less than 3% NA 12.5 1.25 1.5 Tx mask 47CFR90.210d Mod fidelity <5% -55 25, 12.5 NPSPAC 6.25 0.5 Less than 3% NA 2.83 kHz nominal per TIA 102 CAAB 2.83 kHz nominal per TIA 102 CAAB NA 25 6.25 0.5 Tx mask 47CFR90.210d Mod fidelity <5% NPSPAC FM Noise (dB) Channel Spacing (kHz) Synthesizer Step Size (kHz) Frequency Spread Full Spec (MHz) Audio Distortion (@ 1 kHz) NA -55 12.5/25/30 1.25 2 Less than 3% Audio Response (pre-emphasis) NA 0 to ±4 Within +1/-3 dB of 6 Within +1/-3 dB of 6 Within +1/-3 dB of 6 dB/octave, 300 to dB/octave, 300 to dB/octave, 300 to 3000 Hz per EIA 3000 Hz per EIA 3000 Hz per EIA No. of Conventional Channels Up to 12 Up to 12 Up to 12 Up to 12 Up to 12 Up to 12 NOTE: Rated power output is measured at the transmitter power amplifier output connector per FCC Type Acceptance filing information. Any customer-required optional items such as power measuring devices and/or duplexers will introduce loss between the transmitter output connector and the station cabinet output connector. This loss will reduce the available power at the station connector. Receiver (As applicable, analog specifications measured per TIA/EIA-603 Procedure and P25 digital per TIA-102.CAAA-A) Applicable FCC Rules 90 90 NA 90 22, 90 90 Industry Canada Certification Number 3636B-0048 3636B-0050 NA 3636B-0038 3636B-0039 3636B-0036 Applicable Industry Canada Rules RSS-119 RSS-119 NA RSS-119 RSS-119 RSS-119 NTIA Certification Number JF-1208074 JF-1208074 JF-1208074 NA NA NA VHF Analog* VHF P25 Digital UHF Analog* UHF P25 Digital 800 MHz Analog* 800 MHz P25 Digital Frequency Range (MHz) RF Input Impedance () Channel Spacing (kHz) Synthesizer Step Size (kHz) Sensitivity (dBm) EIA (12 dB SINAD) 136-174 50 12.5/25/30 1.25 -116 (0.35 V) 370-512 50 12.5/25 1.25 -116 (0.35 V) -119 (0.25 V) -119 (0.25 V) 370-512 50 12.5 1.25 -116 (5% BER) static, -108 faded NA 806-825 50 25, 12.5 NPSPAC 6.25 -118 (0.28 V) Threshold Squelch (dBm) Selectivity 12.5 kHz 25 kHz 30 kHz Frequency Stability (ppm) 136-174 50 12.5 1.25 -116 (5% BER) (0.35 V) NA 806-825 50 25, 12.5 NPSPAC 6.25 -116 (5% BER) static, -108 faded NA 75 dB 85 dB 90 dB ±1.0 60 dB Dig ACR NA NA ±1.0 75 dB 85 dB NA ±1.0 60 dB Dig ACR NA NA ±0.5 20 dB (NPSPAC) 85 dB NA ±1.0 12.5: ± 1, 25: ± 2 12.5: ±1 12.5: ± 1, 25: ± 2 12.5: ±1 ±2, NPSPAC: 1.6 60 dB Dig ACR NA NA ±0.15 (external freq. std) 12.5: ±1 75 80 80 90 80 NA NA 90 75 80 NA 90 80 NA NA 90 NA 80 NA 90 80 NA NA 90 2.0 2.0 2.0 2.0 0.5 0.5 1 @ <3% distortion NA 1 @ <3% distortion NA 1 @ <3% distortion NA Signal Displacement Bandwidth (kHz) Intermodulation Rejection (dB) 12.5 kHz 25 kHz 30 kHz Spurious and Image Rejection (dB) Frequency Spread Full Specs. (MHz) Audio Output @ 1000 Hz, 25/30 kHz Channel (W) *Audio Response (de-emphasis): for UHF 83.0 (211) 23.1 (59) 21.0 (53) 2175 Hz Regulatory Data Frequency Range (MHz) 136-154 150-174 380-400 403-450 450-512 806-870 Technical specifications are subject to change without notice. Product sales are subject to applicable U.S. export control laws. Within +2/-8 dB of 6 dB/octave (@ Local Speaker), 300 to 3000 Hz per EIA Within +1/-3 dB of 6 dB/octave (@ Line Output), 300 to 3000 Hz per EIA -121 (0.18 V) Technical specifications are subject to change without notice. Product sales are subject to applicable U.S. export control laws. Conventional Options and Accessories General Specifications Conventional Tone and DC Remote Controlled Stations Programmable Options Transmit Frequencies Receive Frequencies Channel Guard Digital and Tone Channel Guard Disable Repeater Disable Intercom Function DTMF Decode Morse Code ID Squelch Tail Elimination (STE) Carrier Control Timer Station Control DC Control Tone Control Repeater DC/Repeat Tone/Repeat 4-Wire Audio Scan Additional Options Service Microphone Antenna Multicoupler 230V Power Supply Duplexer Antenna Relay Combiner Isolator Squelch-Operated Relay Remote Controllers Battery Standby Battery Charger Gel Cell Battery Switchable Channel Spacing Audio (Line to Transmitter) Line Terminating Impedance: Line Level (Adjustable): Frequency Response: Tone Control Function Tones: Secur-it Tone and Transmit Tone: Transmitted 2175 Hz Tone Level: Permissible Control Line Loss @ 2175 Hz: Audio (Receiver to Line) Audio Amplifier Input Impedance: Input Level: Output Impedance to Line: Output Level to Line Voice (1 kHz ref): Tone (1 kHz ref): Frequency Response: Hum and Noise, Noise Squelch: Tone Squelch: DC Control Control Currents: Line Loop Resistance (maximum): Power Output (Adjustable) (W) 10-110 10-110 10-110 10-100 10-100 10-100 FCC Type Acceptance Number OWDTR-0048-E OWDTR-0050-E NA OWDTR-0038-E OWDTR-0039-E OWDTR-0036-E INDOOR CABINET (Floor Mount) 69 inches 83 inches CABINET Size [in. (cm)] Height Width Depth 600 -20 to +7 dBm ±3 dB @ 300-3000 Hz 69.1 (175) 23.1 (59) 21.0 (53) Weight (min) [(lb (kg)] Continuous Duty Packed, Domestic Shipping 650, 750, 850, and 950 for P25 only 1050, 1150, 1250, 1350, 1450, 1550, 1650, 1750, 1850, 1950, and 2050 Hz 576 (261) 606 (275) Service Speaker: 1W @ 8 Service Microphone: Transistorized Dynamic Duty Cycle (EIA) Continuous: Ambient Temperature (or full spec performance per EIA): Transmit/Receive - 100% Humidity (EIA): Input Power Source: Optional Input Power Source: Standby Battery Source: Antenna Connections: Length of AC Power Cable: Metering: Altitude: 693 (315) 729 (331) Number of Rack Units 33 41 Max. Units w/Power Supply 4 5 NOTE: One rack unit equals 1.75 inches. Stations occupy 6 rack units of cabinet space. Operable: Shippable: -22 to +140oF (-30 to +60oC)* 90% @ 122oF (50oC) 120 VAC (±20%), 47-63 Hz 230 VAC (±15%), 47-63 Hz 26.4 VDC, 50 AH (min.) Type N 10 ft (3048 mm) Provided through Handset or TQ0619 Software Up to 15,000 ft (4,570 m) Up to 50,000 ft (15,250 m) *Standard network equipment for P25IP and EDACS IP configurations (0-40oC). Expanded temperature range equipment is available on request. 20 dB Below Voice Source Power Drain VHF Analog Frequency Range (MHz) 30 dB AC Input Power 10 K 1 V RMS (for 5 kHz Deviation) 600 +7 dBm (Adjustable) +7 dBm (Reference 7 dBm) +1 and -3 dB @ 300-3000 Hz -55 dB (Reference 7 dBm) -30 dB (Reference 7 dBm) -2.5, ±6, and ±11 mA 11 K (Includes 3K Termination) DC Input Power (A) Tx (full/half) Power Rx Power Tx (full/half) Power Rx Power VDC 13.8 13.8 26.4 26.4 VHF P25 Digital UHF Analog UHF P25 Digital 800 MHz Analog 800 MHz P25 Digital 851-870 TX, 806-825 RX 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 851-870 TX, 806-825 RX 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 136-174 136-174 380-512 380-512 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 5A @ 120 VAC or 3A @ 230 VAC A 2 2 12/8 0.5 Transmitter (As applicable, analog specifications measured per TIA/EIA-603 Procedure and P25 digital per TIA-102.CAAA-A) VHF Analog VHF P25 Digital UHF Analog UHF P25 Digital 800 MHz Analog 800 MHz P25 Digital Frequency Range (MHz) Rated Power Output (W) RF Output Impedance () Conducted Spurious and Harmonic Emission Frequency Stability (ppm) 136-174 110 50 136-174 110 50 380-512 100 50 380-512 100 50 851-870 100 50 851-870 100 50 -36 dBm ±1.0 -70 dBc ±1.0 -36 dBm ±1.0 -70 dBc ±0.5 (CAAB 3.2.2) external frequency std -36 dBm ±1.0 -70 dBc ±0.15 external frequency std Modulation Deviation (kHz) Wideband Narrowband 0 to ±5 0 to ±2.5 NA 2.83 kHz nominal per TIA 102 CAAB NA 0 to ±5 0 to ±2.5 NA 2.83 kHz nominal per TIA 102 CAAB NA 0 to ±5 NA NA 12.5 1.25 1.5 Tx mask 47CFR90.210d Mod fidelity <5% -55 12.5/25 1.25 2 Less than 3% NA 12.5 1.25 1.5 Tx mask 47CFR90.210d Mod fidelity <5% -55 25, 12.5 NPSPAC 6.25 0.5 Less than 3% NA 2.83 kHz nominal per TIA 102 CAAB 2.83 kHz nominal per TIA 102 CAAB NA 25 6.25 0.5 Tx mask 47CFR90.210d Mod fidelity <5% NPSPAC FM Noise (dB) Channel Spacing (kHz) Synthesizer Step Size (kHz) Frequency Spread Full Spec (MHz) Audio Distortion (@ 1 kHz) NA -55 12.5/25/30 1.25 2 Less than 3% Audio Response (pre-emphasis) NA 0 to ±4 Within +1/-3 dB of 6 Within +1/-3 dB of 6 Within +1/-3 dB of 6 dB/octave, 300 to dB/octave, 300 to dB/octave, 300 to 3000 Hz per EIA 3000 Hz per EIA 3000 Hz per EIA No. of Conventional Channels Up to 12 Up to 12 Up to 12 Up to 12 Up to 12 Up to 12 NOTE: Rated power output is measured at the transmitter power amplifier output connector per FCC Type Acceptance filing information. Any customer-required optional items such as power measuring devices and/or duplexers will introduce loss between the transmitter output connector and the station cabinet output connector. This loss will reduce the available power at the station connector. Receiver (As applicable, analog specifications measured per TIA/EIA-603 Procedure and P25 digital per TIA-102.CAAA-A) Applicable FCC Rules 90 90 NA 90 22, 90 90 Industry Canada Certification Number 3636B-0048 3636B-0050 NA 3636B-0038 3636B-0039 3636B-0036 Applicable Industry Canada Rules RSS-119 RSS-119 NA RSS-119 RSS-119 RSS-119 NTIA Certification Number JF-1208074 JF-1208074 JF-1208074 NA NA NA VHF Analog* VHF P25 Digital UHF Analog* UHF P25 Digital 800 MHz Analog* 800 MHz P25 Digital Frequency Range (MHz) RF Input Impedance () Channel Spacing (kHz) Synthesizer Step Size (kHz) Sensitivity (dBm) EIA (12 dB SINAD) 136-174 50 12.5/25/30 1.25 -116 (0.35 V) 370-512 50 12.5/25 1.25 -116 (0.35 V) -119 (0.25 V) -119 (0.25 V) 370-512 50 12.5 1.25 -116 (5% BER) static, -108 faded NA 806-825 50 25, 12.5 NPSPAC 6.25 -118 (0.28 V) Threshold Squelch (dBm) Selectivity 12.5 kHz 25 kHz 30 kHz Frequency Stability (ppm) 136-174 50 12.5 1.25 -116 (5% BER) (0.35 V) NA 806-825 50 25, 12.5 NPSPAC 6.25 -116 (5% BER) static, -108 faded NA 75 dB 85 dB 90 dB ±1.0 60 dB Dig ACR NA NA ±1.0 75 dB 85 dB NA ±1.0 60 dB Dig ACR NA NA ±0.5 20 dB (NPSPAC) 85 dB NA ±1.0 12.5: ± 1, 25: ± 2 12.5: ±1 12.5: ± 1, 25: ± 2 12.5: ±1 ±2, NPSPAC: 1.6 60 dB Dig ACR NA NA ±0.15 (external freq. std) 12.5: ±1 75 80 80 90 80 NA NA 90 75 80 NA 90 80 NA NA 90 NA 80 NA 90 80 NA NA 90 2.0 2.0 2.0 2.0 0.5 0.5 1 @ <3% distortion NA 1 @ <3% distortion NA 1 @ <3% distortion NA Signal Displacement Bandwidth (kHz) Intermodulation Rejection (dB) 12.5 kHz 25 kHz 30 kHz Spurious and Image Rejection (dB) Frequency Spread Full Specs. (MHz) Audio Output @ 1000 Hz, 25/30 kHz Channel (W) *Audio Response (de-emphasis): for UHF 83.0 (211) 23.1 (59) 21.0 (53) 2175 Hz Regulatory Data Frequency Range (MHz) 136-154 150-174 380-400 403-450 450-512 806-870 Technical specifications are subject to change without notice. Product sales are subject to applicable U.S. export control laws. Within +2/-8 dB of 6 dB/octave (@ Local Speaker), 300 to 3000 Hz per EIA Within +1/-3 dB of 6 dB/octave (@ Line Output), 300 to 3000 Hz per EIA -121 (0.18 V) ® P25 Conventional MASTR III Station VHF, UHF, 800 MHz The MASTR III P25 digital Base Station provides Secure digital communications for mission-critical applications Capability for both conventional Project 25 digital communications and conventional analog communications Capability of delivering Internet Protocol (IP) data and voice to a Harris P25IP network The MASTR III P25 provides the flexibility to commission a base station that will meet critical communication needs today and into the future. Whether users are designing a conventional Project 25 system, a conventional VHF system, or an IP-based P25 network, the MASTR III P25 keeps pace with their needs. Flexible, Efficient P25 Design The MASTR III P25 incorporates P25 digital voice and data using a digital signal processor modem for maximum design flexibility. The station can be configured for P25 mode, and can communicate with the user’s current analog dispatch network through a 4wire audio port. The P25 digital voice is translated through an onboard voice encoder/decoder in the station to allow immediate access to P25 communications through the user’s existing network. Public Safety and Professional Communications | www.pspc.harris.com 221 Jefferson Ridge Parkway | Lynchburg, VA USA 24501 | 1-800-368-3277 (+1-434-455-6403) Harris, assuredcommunications, and MASTR are registered trademarks of Harris Corporation. Copyright 2012 Harris Corporation. All rights reserved. Printed in U.S.A. 11/12 ECR-7342J The MASTR III P25 can also be configured for normal conventional analog operation at sites where P25 currently is not in use. P25IP Network As network needs expand, the MASTR III P25 is ready to grow to meet the communication requirements of the 21st century. The MASTR III P25 and a SitePro Controller enable IP voice and data packets to be sent over a Harris P25IP network and be received at the base station. This setup enables all of the advantages of IP: Seamless integration of offthe-shelf IP data applications. Easy interconnection of peripherals and ancillary equipment such as mobile data terminals, printers, scanners, and video devices for user organizations. Economical routing and backhaul of network data. Redundancy benefit of distributed IP architecture, one of the key requirements for most public safety users. Programmable Flexibility PC programmable options provide flexibility, simplified setup, and easy field upgrades. The fully synthesized design of the MASTR III P25 base station allows the user to make frequency changes quickly, easily, and affordably. The modular design of the base station makes maintenance and servicing simple and fast.