MASTR III, P25(IP) - Harris Corporation

P25IP Trunked MASTR® III Station
VHF, UHF, 800 MHz
The MASTR III P25IP Base Station

Provides secure digital P25IP trunked
communications

Delivers Internet Protocol (IP) voice and data
with an optional SitePro Controller

Incorporates a modular design for easy
maintenance
The MASTR III P25IP provides
the flexibility to commission a
base station that will meet
critical communication needs
today and into the future.
Flexible, Efficient P25IP Design
The MASTR III P25IP incorporates P25 digital voice and data
using a digital signal processor
modem for maximum design
flexibility. P25 digital voice is
translated through an on-board
voice encoder/decoder in the
station to allow immediate
access to P25 communications
through the user’s existing
network.
P25IP Network
As network needs expand, the
MASTR III P25 station is ready
to grow to meet the communication requirements of the 21st
century. The MASTR III P25 and
a SitePro Controller enable IP
voice and data packets to be
sent over a Harris P25IP network
and be received at the base
station. This setup enables all of
the advantages of IP:



Seamless integration of offthe-shelf IP data applications.
Easy interconnection of
peripherals and ancillary
equipment such as mobile
data terminals, printers,
scanners, and video devices
for user organizations.
Economical routing and
backhaul of network data.

Redundancy benefit of
distributed IP architecture,
one of the key requirements
for most public safety users.
Programmable Flexibility
PC programmable options
provide flexibility, simplified
setup, and easy field upgrades.
The fully synthesized design of
the MASTR III P25IP base
station allows the user to make
frequency changes quickly,
easily, and affordably.
The modular design of the
base station makes maintenance and servicing simple and
fast.
Technical specifications are subject to change without notice. Product sales are subject to applicable U.S. export control laws.
General Specifications
Cabinet
Rack
69 inches
83 inches
86 inches
Number of Rack Units:
33
41
46
Max. Units w/Power Supply:
4
5
5
Note: One rack unit equals 1.75 inches. Stations occupy 6 rack units of cabinet space.
Service Speaker:
1W @ 8
Service Microphone:
Transistorized Dynamic
Duty Cycle (EIA) Continuous:
Transmit/Receive - 100%
Humidity (EIA):
90% @ 122oF (50oC)
Ambient Temperature (or full spec
performance per EIA):
-22 to +140oF (-30 to +60oC)*
Input Power Source:
120 VAC (±20%), 47-63 Hz
Optional Input Power Source:
Standby Battery Source:
Antenna Connections:
Length of AC Power Cable:
Metering:
Altitude:
Operable:
Shippable:
230 VAC (±15%), 47-63 Hz
26.4 VDC, 50 AH (min.)
Type N
10 ft (3048 mm)
Provided through Handset or TQ0619 Software
Up to 15,000 ft (4,570 m)
Up to 50,000 ft (15,250 m)
IP
o
*Standard network equipment for P25 and EDACS IP configurations (0-40 C). Expanded
temperature range equipment is available on request.
Source Power Drain
VHF P25 Digital
UHF P25 Digital
800 MHz P25 Digital
Frequency Range (MHz)
136-174
350-512
5A @ 120 VAC or
3A @ 230 VAC
A
2
2
12/8
0.5
5A @ 120 VAC or
3A @ 230 VAC
A
2
2
12/8
0.5
851-870 TX,
806-825 RX
5A @ 120 VAC or
3A @ 230 VAC
A
2
2
12/8
0.5
AC Input Power
DC Input Power (A)
Tx (full/half) Power
Rx Power
Tx (full/half) Power
Rx Power
VDC
13.8
13.8
26.4
26.4
Transmitter (As applicable, analog specifications measured per TIA/EIA-603 Procedure and P25 digital per TIA-102.CAAA-A)
Frequency Range (MHz)
Rated Power Output (W)
RF Output Impedance ()
Conducted Spurious and
Harmonic Emission
Frequency Stability (ppm)
Modulation Deviation (kHz)
Wideband
Narrowband
NPSPAC
FM Noise (dB)
Channel Spacing (kHz)
Synthesizer Step Size (kHz)
Frequency Spread Full Spec (MHz)
Audio Distortion (@ 1 kHz)
Audio Response (pre-emphasis)
No. of Conventional Channels
NOTE:
VHF P25 Digital
UHF P25 Digital
800 MHz P25 Digital
136-174
110
50
350-512
100
50
851-870
100
50
-70 dBc
±1.5
-70 dBc (spurious emission)
±0.5 (CAAB 3.2.2) external frequency std
-70 dBc (spurious emission)
±0.15 external frequency std
NA
2.83 kHz nominal per TIA 102 CAAB
NA
NA
12.5
1.25
1.5
Tx mask 47CFR90.210d
Mod fidelity <5%
Up to 12
NA
2.83 kHz nominal per TIA 102 CAAB
NA
NA
12.5
1.25
1.5
Tx mask 47CFR90.210d
Mod fidelity <5%
Up to 12
2.83 kHz nominal per TIA 102 CAAB
NA
2.83 kHz nominal per TIA 102 CAAB
NA
25
6.25
0.75
Tx mask 47CFR90.210d
Mod fidelity <5%
Up to 12
Rated power output is measured at the transmitter power amplifier output connector per FCC Type Acceptance filing information. Any customer-required optional items such as power
measuring devices and/or duplexers will introduce loss between the transmitter output connector and the station cabinet output connector. This loss will reduce the available power at the
station connector.
Receiver (As applicable, analog specifications measured per TIA/EIA-603 Procedure and P25 digital per TIA-102.CAAA-A)
Frequency Range (MHz)
RF Input Impedance ()
Channel Spacing (kHz)
Synthesizer Step Size (kHz)
Sensitivity (dBm) EIA
Threshold Squelch (dBm)
Selectivity
12.5 kHz
25 kHz
30 kHz
Frequency Stability (ppm)
Signal Displacement Bandwidth (kHz)
Intermodulation Rejection (dB)
12.5 kHz
25 kHz
30 kHz
Spurious and Image Rejection (dB)
Frequency Spread
Full Specs. (MHz)
Audio Output @ 1000 Hz, 25/30 kHz
Channel (W)
*Audio Response (de-emphasis):
VHF P25 Digital
UHF P25 Digital
800 MHz P25 Digital
136-174
50
12.5
1.25
-116 (5% BER), (0.35 V)
NA
350-512
50
12.5
1.25
-116 (5% BER) static, -108 faded
NA
806-825
50
25, 12.5 NPSPAC
6.25
-116 (5% BER) static, -108 faded
NA
60 dB Dig ACR, 70 dB Analog ACR
NA
NA
±1.5
±1
60 dB Dig ACR, 70 dB Analog ACR
NA
NA
±0.5
±1
60 dB Dig ACR, 70 dB Analog ACR
60 dB Dig ACR, 70 dB Analog ACR
NA
±0.15 (external freq. std)
±1
80
NA
NA
90
80
NA
NA
90
NA
80
NA
90
2.0
2.0 (1.0 for 350-370 MHz)
0.5
NA
NA
Within +2/-8 dB of 6 dB/octave (@ Local Speaker), 300 to 3000 Hz per EIA
Within +1/-3 dB of 6 dB/octave (@ Line Output), 300 to 3000 Hz per EIA
NA
Regulatory Data
Frequency
Range
(MHz)
Power Output
(Adjustable)
(W)
FCC Type
Acceptance Number
Applicable
FCC
Rules
Industry Canada
Certification
Number
Applicable
Industry Canada
Rules
NTIA
Certification
Number
136-154
150-174
380-400
403-450
450-512
806-870
10-110
10-110
10-100
10-100
10-100
10-100
OWDTR-0048-E
OWDTR-0050-E
NA
OWDTR-0038-E
OWDTR-0039-E
OWDTR-0036-E
90
90
NA
90
22, 90
90
3636B-0048
3636B-0050
NA
3636B-0038
3636B-0039
3636B-0036
RSS-119
RSS-119
NA
RSS-119
RSS-119
RSS-119
JF-1208074
JF-1208074
JF-1208074
NA
NA
NA
for UHF
Public Safety and Professional Communications | www.pspc.harris.com
221 Jefferson Ridge Parkway | Lynchburg, VA USA 24501 | 1-800-368-3277 (+1-434-455-6403)
Harris, assuredcommunications, and MASTR are registered trademarks of Harris Corporation.
Copyright  2012 Harris Corporation. All rights reserved.
Printed in U.S.A. 11/12 ECR-7379F