dc12-12 data sheet 1-23

EXTREME WIDE RANGE INPUT
DC-DC CONVERTER
DC12-12
The Intronics Power Inc. DC12-12 is a versatile extreme wide input voltage range multi
output DC-DC power converter.
FEATURES
• Input voltage 15-350VDC
• Output Voltage 12V, 5V (non isolated) and
12V isolated
• Output 2 watts
• Shutdown function
• Trim input
• Operating Temperature Range -40 to +65
degrees C
APPLICATIONS
•
•
•
•
•
•
•
Remote system monitoring
Solar energy
High side transistor drive power
Electric vehicle subsystems
Microcontroller power subsystems
Power converters
Inverters
1400 PROVIDENCE HIGHWAY •
BUILDING 2 NORWOOD,
MASSACHUSETTS 02062-5015
PHONE: 781-551-5500 FAX: 781-551-5555
GENERAL
The Intronics 12-12DC is a self contained DC to DC
power converter. Its input voltage range is 14-350VDC.
It has three outputs,
V1 12V 200mA non isolated
V2 +5v 50 mA non isolated
V3 12V 100 mA isolated.
Total output power rating is 2 watts.
REGULATION
The Intronics DC12-12 is a fully encapsulated PCB
mount module. The 12V and 5V non isolated outputs
share a common ground with the input. The 12V
isolated output is has 1500V isolation from the other
circuitry.
Voltage regulation of the nonisolated outputs is <3%.
The isolated output can vary between 11 and 15V,
depending on the ratio of isolated to non isolated
current drawn.
If I(V3)<I(V1 + V2), V3>V1.
If I(V3)>I(V1 + V2), V3<V1.
See Fig 3
STARTUP
This module will start reliably at full load with
Vin>30V. It will also start at lower input voltages with
reduced output power. Once started, it will run with
the input voltage as low as 4 volts at reduced output
power. See Fig 4.
1400 PROVIDENCE HIGHWAY •
BUILDING 2 NORWOOD,
MASSACHUSETTS 02062-5015
PHONE: 781-551-5500 FAX: 781-551-5555
SHUTDOWN
Pulling the SHTDN pin to ground will cause the
converter to stop operating. Letting this pin float will
cause the converter to resume operation.
TRIM INPUT
Connecting a 100K potentiometer between V1+ and
GND with the wiper connected to the TRIM pin will
adjust V1 from 10.2 to 13.2V. If no adjustment is
needed, the TRIM pin can be left unconnected.
Fixed resistors can also be connected between TRIM
and V1+ or GND for trim purposes.
ISOLATION
The negative input is common to the 12V and 5V non
isolated outputs. The isolated 12V output is rated
1500V relative to all other inputs and control pins.
SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
Maximum Input Voltage
400V
Maximum Output Power
2.5 Watts
Outline Drawing
NORMAL OPERATING CONDITIONS
Voltage 0-350V
Max Continuous Output Power 2 Watts
Storage Temperature Range -40 to +70 degrees C
Operating Temperature Range -40 to +65 degrees C
1400 PROVIDENCE HIGHWAY • BUILDING 2
NORWOOD, MASSACHUSETTS 02062-5015
PHONE: 781-551-5500 FAX: 781-551-5555
PHYSICAL
Dimensions: Length: 2.050 Max
Width: 1.550 Max
Height: .800 Max
Weight: 2 oz
Pin Extension: .180 Min
Pin Dia: .040 ±.002
Pin Plating: gold over Nickel