RECOM RAC04

Features
Regulated
Converters
●
●
●
●
●
●
●
POWERLINE
Universal Input 90-305VAC
High efficiency up to 79%
Isolated Output 3.75kVAC / 1 min
Short Circuit Protection
Maximum No Load <50mW, Maximum Input Power
<0.5W @0.3W Output Power
Meet EN55022 Class B
Fixed Output Voltage
AC/DC-Converter
with 3 year Warranty
Selection Guide
Part
Number
RAC04-3.3SC/277
Input
Voltage
(VAC)
90-305
Output
Voltage
(VDC)
3.3
Output
Current
(max.)
1200
Efficiency
(Typ.)
72
Max.
Capacitive
Load
10000
RAC04-05SC/277
90-305
5
800
75
7200
RAC04-12SC/277
90-305
12
333
78
1000
RAC04-15SC/277
90-305
15
267
79
820
RAC04-24SC/277
90-305
24
167
79
220
RAC04-0512DC/277
90-305
5/12
720/33
75
4700/100
RAC04-05DC/277
90-305
±5
±400
76
±3300
RAC04-12DC/277
90-305
±12
±166
78
±680
4 Watt
Single / Dual
Output
Specifications (measured at TA 25°C, full load after warm-up)
Input Voltage Range
90-305VAC or 127-430VDC
Input Frequency
47-440Hz
Input Current (Full Load)
115VAC/230VAC
98mA / 64mA max.
Inrush Current
115VAC/230VAC
15A / 30A max.
115VAC/230VAC/277VAC / 50/60Hz
Output Voltage Accuracy (Full Load)
50mW max.
Single Outputs
±2% typ.
Dual Outputs
5V/12V
Line Voltage Regulation (90-305VAC)
±2% typ.
±2% / ±10% typ.
Single Outputs
Dual Outputs
5V/12V
Load Voltage Regulation
(5V Minimum Load 5% @12V Full Load)
Output Ripple&Noise @115/230VAC
(20MHz limited)
±0.2% typ.
±0.2% / ±1% typ.
3.3V/5V Output
±1% typ.
All Others
0.5% typ.
5V/12V
150mV max.
All Others
100mV max.
67kHz
Hold-Up Time (@115VAC)
15ms min.
5V/12V
Isolation Voltage
Input-Output
Leakage Current
277VAC / 50Hz
0%
80
3.75kVAC / 1minute
60
0.25mA max.
Isolation Resistance
100M Ω min.
Short Circuit Protection
Auto Recovery
Storage Temperature Range
Case Material
100
5% / 0% typ.
All Others
(Natural Convection, with Derating)
(Ambient Temperature)
150mV/- max.
Switching Frequency (Full Load)
Operating Temperature Range
Derating Graph
±1%/- typ.
3.3V/5V/±5V Output
5V/12V
Minimum Load
RAC04/277
±0.2% typ.
-25°C to +65°C (without Derating)
Load (%)
No Load Power Consumption
EN-60950-1 (pending)
UL-60590-1 (pending)
50
Safe Operating Area
40
20
0
-40°C to +100°C
60 70 80
65
UL94V-0 Black Plastic
Ambient Temperature Range (°C)
-25°C to +80°C (with Derating)
-25
0
20
40
continued on next page
www.recom-international.com
REV:0/2012
1
100
RAC04-xxSC/277
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Relative Humidity
Non Condensing
95% RH max.
Package Weight
31.5g typ.
Physical Dimenstions
(LxWxH)
EMC
36.7x27.2x17.1 mm
Conducted and Radiated
MTBF (+25°C)
EN55022 Class B
Noise Immunity
EN55024
MIL-HDBK-217F
500 x 10³ hours
Certification
CE
EN55022 Class B
UL General Safety
UL60950-1, 2nd Edition
EN General Safety
EN60950-1, 2nd Edition
Specifications (measured at TA 25°C, full load after warm-up)
RAC04C-3.3SH
RAC04C-05SH
100
80
70
60
50
40
30
90
90
115VAC
230VAC
90VAC
277VAC
264VAC
300VAC
80
70
60
50
40
30
70
60
50
40
30
20
20
10
10
10
0
0
0 10 20 30 40 50 60 70 80 90 100
0
0 10 20 30 40 50 60 70 80 90 100
0 10 20 30 40 50 60 70 80 90 100
Load (%)
Load (%)
RAC04C-05DH
RAC04C-15SH
100
60
50
40
30
80
70
60
50
40
30
20
20
10
10
0 10 20 30 40 50 60 70 80 90 100
Load (%)
230VAC
115VAC
264VAC
277VAC
90VAC
300VAC
0
90
Efficiency (%)
70
100
90
Efficiency (%)
230VAC
115VAC
264VAC
277VAC
300VAC
90VAC
80
0
RAC04C-12DH
100
90
115VAC
90VAC
277VAC
230VAC
300VAC
264VAC
80
20
Load (%)
Efficiency (%)
Efficiency (%)
230VAC
115VAC
90VAC
264VAC
300VAC
277VAC
Efficiency (%)
Efficiency (%)
RAC04/277
100
100
90
2
RAC04C-12SH
115VAC
230VAC
264VAC
277VAC
90VAC
300VAC
80
70
60
50
40
30
20
10
0 10 20 30 40 50 60 70 80 90 100
Load (%)
REV:0/2012
0
0 10 20 30 40 50 60 70 80 90 100
Load (%)
www.recom-electronic.com
RAC04-xxSC/277
Series
POWERLINE
AC/DC-Converter
Specifications (measured at TA 25°C, full load after warm-up)
Application Note:
RAC04C-0512DH
100
90
230VAC
115VAC
264VAC
277VAC
90VAC
300VAC
Efficiency (%)
80
70
L
Fuse 1A
60
Vout+
VAC (L)
0.1uF/50V
Load
50
N
40
30
Vout-
VAC (N)
47uF/50V
20
10
0
0 10 20 30 40 50 60 70 80 90 100
1. Recommended external input fuse 1A/slow blow type.
2. To measure the output ripple & noise short runs by
0.1uF/50V&47uF/50V @20MHz, nominal input and full load.
Please see as above.
3. That Pin 7 is NC but need 3mm minimum clearance to ground
for safety.
Load (%)
Package Style and Pinning
3rd angle
projection
27.2
26.5
36.7
36.0
17.1
4.0
21.0
0.6
21.5
3.1
7
Pin Connections
7.5
6
Pin #
5
Primary
Isolation
Spacing
21.0
1
3.8
2 3 4
21.5
www.recom-international.com
Secondary
Single Out
Dual Output
Dual Output
1
No Pin
No Pin
No Pin
2
+VDC out
+Vout
+Vout
3
-VDC out
Com
Com
4
NC
-Vout
+12V
5
VAC in (L)
VAC in (L)
VAC in (L)
6
VAC in (N)
VAC in (N)
VAC in (N)
7
NC
NC
NC
NC = No Connection
xx.x = ±0.5mm
xx.xx = ±0.25mm
3.75x2
REV:0/2012