PK 80160

ISSUE 2
Installation Instructions for the
Compensated and Calibrated Pressure Sensors
PK 80160
XCXL, XCX Series
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or
emergency stop devices, or in any other application
where failure of the product could result in personal
injury.
Failure to comply with these instructions could
result in death or serious injury.
GENERAL INFORMATION
The XCXL, XCX Series integrates silicon
micromachined sensing technology, temperature
compensation and calibration in an improved
performance industry standard package. Additional
stability and long-term accuracy improvements are
gained through simplified compensation
techniques, which eliminate temperature dependent
thermal compensation.
This series is available in a commercial (XCXDNC) performance level. This performance level
provides the calibration accuracy of offset thermal
compensation and linearity providing added
flexibility to meet critical performance budgets. The
XCA and XCR Series provide amplified output as
well as integrated compensation.
SOLDERING/ASSEMBLY
Limit soldering to 315 °C [600 °F] maximum, with
duration of five seconds maximum. Leads must be
adequately supported during any forming/shearing
operation to ensure that the leads are not stressed
inside the plastic case.
EQUIVALENT CIRCUIT
Sensing and Control
PIN DESIGNATIONS
1. N/C
2. + V Excitation
3. + Output Signal
4. + V Excitation
5. – Output Signal
6. N/C
ELECTRICAL SPECIFICATIONS
@ 25 °C, 12 Vdc (unless otherwise noted)
Pressure Range
0 in H2O [0 mBar] to
4 in H2O [10 mBar]
0 in H2O to [0 mBar] to
10 in H2O [25 mBar]
0.3 psi to 150 psi
0 mV Typ.
Null XCX/XCXL
Span (P2>P1)
0 H2O to 4 in H2O
40 mV Typ.
0 H2O to 10 in H2O
20 mV Typ.
0 psi to 0.3 psi
20 mV Typ.
0 psi to 1 psi
18 mV Typ.
60 mV Typ.
0 psi to 5 psi
0 psi to 15 psi
90 mV Typ.
0 psi to 30 psi
90 mV Typ.
0 psi to 60 psi
90 mV Typ.
0 psi to 100 psi
100 mV Typ.
0 psi to 150 psi
Supply Voltage
90 mV Typ.
3 Vdc to 16 Vdc
ENVIRONMENTAL SPECIFICATIONS
Operating
Temperature
-25 °C to 85 °C
[-13 °F to 185 °F]
Storage
Temperature
-40 °C to 125 °C
[-40 °F to 257 °F]
Hysteresis and
Linearity
0.5% Span, Typ.
Media Compatibility
P1 Port (Dry Gases Only):
Media must be compatible with
epoxy-based adhesive.
P2 Port: Media must be
compatible with nylon housing,
epoxy adhesive and silicon.
© Honeywell 2003, All Rights Reserved
XCXL, XCX Series
Issue 2 PK 80160
MOUNTING DIMENSIONS (for reference only) mm/in
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture
as being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of
coverage, Honeywell will repair or replace without
charge those items it finds defective. The
foregoing is Buyer’s sole remedy and is in lieu of
all other warranties, expressed or implied,
including those of merchantability and fitness
for a particular purpose.
Specifications may change without notice. The
information we supply is believed to be accurate
and reliable as of this printing. However, we
assume no responsibility for its use.
While we provide application assistance
personally, through our literature and the
Honeywell web site, it is up to the customer to
determine the suitability of the product in the
application.
For application assistance, current
specifications, or name of the nearest Authorized
Distributor, contact a nearby sales office. Or call:
1-800-537-6945 USA
1-800-737-3360 Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
[email protected]
Sensing and Control
Honeywell
11 West Spring Street
Freeport, Illinois 61032
P80160-2-EN IL50 GLO 303 Printed in USA
www.honeywell.com/sensing