ISSUE 2 Installation Instructions for the Compensated and Calibrated Pressure Sensors PK 80160 XCXL, XCX Series WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. GENERAL INFORMATION The XCXL, XCX Series integrates silicon micromachined sensing technology, temperature compensation and calibration in an improved performance industry standard package. Additional stability and long-term accuracy improvements are gained through simplified compensation techniques, which eliminate temperature dependent thermal compensation. This series is available in a commercial (XCXDNC) performance level. This performance level provides the calibration accuracy of offset thermal compensation and linearity providing added flexibility to meet critical performance budgets. The XCA and XCR Series provide amplified output as well as integrated compensation. SOLDERING/ASSEMBLY Limit soldering to 315 °C [600 °F] maximum, with duration of five seconds maximum. Leads must be adequately supported during any forming/shearing operation to ensure that the leads are not stressed inside the plastic case. EQUIVALENT CIRCUIT Sensing and Control PIN DESIGNATIONS 1. N/C 2. + V Excitation 3. + Output Signal 4. + V Excitation 5. – Output Signal 6. N/C ELECTRICAL SPECIFICATIONS @ 25 °C, 12 Vdc (unless otherwise noted) Pressure Range 0 in H2O [0 mBar] to 4 in H2O [10 mBar] 0 in H2O to [0 mBar] to 10 in H2O [25 mBar] 0.3 psi to 150 psi 0 mV Typ. Null XCX/XCXL Span (P2>P1) 0 H2O to 4 in H2O 40 mV Typ. 0 H2O to 10 in H2O 20 mV Typ. 0 psi to 0.3 psi 20 mV Typ. 0 psi to 1 psi 18 mV Typ. 60 mV Typ. 0 psi to 5 psi 0 psi to 15 psi 90 mV Typ. 0 psi to 30 psi 90 mV Typ. 0 psi to 60 psi 90 mV Typ. 0 psi to 100 psi 100 mV Typ. 0 psi to 150 psi Supply Voltage 90 mV Typ. 3 Vdc to 16 Vdc ENVIRONMENTAL SPECIFICATIONS Operating Temperature -25 °C to 85 °C [-13 °F to 185 °F] Storage Temperature -40 °C to 125 °C [-40 °F to 257 °F] Hysteresis and Linearity 0.5% Span, Typ. Media Compatibility P1 Port (Dry Gases Only): Media must be compatible with epoxy-based adhesive. P2 Port: Media must be compatible with nylon housing, epoxy adhesive and silicon. © Honeywell 2003, All Rights Reserved XCXL, XCX Series Issue 2 PK 80160 MOUNTING DIMENSIONS (for reference only) mm/in WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For application assistance, current specifications, or name of the nearest Authorized Distributor, contact a nearby sales office. Or call: 1-800-537-6945 USA 1-800-737-3360 Canada 1-815-235-6847 International FAX 1-815-235-6545 USA INTERNET www.honeywell.com/sensing [email protected] Sensing and Control Honeywell 11 West Spring Street Freeport, Illinois 61032 P80160-2-EN IL50 GLO 303 Printed in USA www.honeywell.com/sensing