L41../L61.. SERIES THERMOSTAT (AQUASTAT) PRODUCTION HANDBOOK APPLICATION The L41../L61.. series aquastats are primarily designed for application on water filled heating systems and systems for hot water supply, mainly domestic use. Contents Subject to change without notice. All rights reserved. General page Description of device functions ......................................... 2 Description ........................................................................ 3 Overview/selection guide ................................................. 4 Features ............................................................................ 5 Aquastat series L4188 - L6188 .................................................................. 6 L4189 - L6189 .................................................................. 8 L6190 ............................................................................. 10 L4191 - L6191 ................................................................ 12 L6188A 2044 Tradeline .................................................. 14 Performance .................................................................... 16 Construction .................................................................... 17 Various Accessories and spare parts ........................................... 18 Quality assurance statement ........................................... 20 Standards and approvals ................................................ 20 Ordering information ........................................................ 21 1 EN2R-9005 0406R3-NE DESCRIPTION OF DEVICE FUNCTIONS The Micro Switch mechanism is intended to control electrically a burner, a relay, etc. in dependency of the temperature changes in a heating system. On choice the Micro Switch mechanism can be delivered with the following contact arrangements: • Single Pole Single Throw, C-1 breaks on temperature rise • Single Pole Double Throw, C-1 breaks on temperature rise. C-2 makes on temperature rise. The contacts are connected to 6.3 mm terminals which are extending from the outside of the Aquastat housing. Aquastats thermostats Honeywell manufactures a coprehensive range of water temperature thermostats (trade name Aquastat) for controlling and limiting boiler water temperature in hydronic heating systems. These sensitive, fast response devices are available in either direct, panel or surface mount versions. Sensing element The liquid filled sensing element, including well or sensor assembly, responds to temperature changes of water in a heating system. The sensor element has a diaphragm type power head connected to a tube type capsule, through a small bore capillary. Expansion of the liquid, which completely fills the sensing element, is the means of motion of the diaphragm. The sensor assembly, used on the surface mounted aquastat, envelopes the sensing capsule by means of an aluminium heat shield for better heat conduction, an insulator of glasswool and a mounting bracket. Cover and conduit entries The housing(s) of the Aquastat can be provided with conduit boxes which are provided with holes to fit Pg 13.5 conduits. To obtain easy wiring possibilities these boxes can be mounted or disconnect without the use of tools (hook in approach). The conduit box is locked with the front cover, which is fastened by means of an M3 thread forming screw. Also the top cover is locked by the front cover. Control mechanism The control mechanism is mounted into the thermoplastic housing. The mechanism transfers the motion of the diaphragm to a snap action switch (Micro Switch) and also provides the facility to adjust the temperature level on which the Micro Switch has to operate. The mechasnism consists of a two piece lever with calibration screw, a plastic actuator for the switch, a cam and shaft for the set-point adjustment, a loading spring for cam and levers and a pad with pushplate to transfer the diaphragm motion to the lever. Set-point stops On request, the Aquastat can be delivered with a high and low limit stop. The purpose of these stops is to provide the user with the facility to choose a maximum and/or minimum setting on the scale. The stop is situated on the rear side of the setting knob. Adjustment is only possible after removal of the knob. Manual or tool reset On request, the Aquastat can be delivered with a manual reset or a tool reset feature. The tool reset feature is covered by the front cover. Operating of the reset button is only possible after removal of the front cover. The manual reset button potrudes the front cover of the Aquastat and resetting can be done without the use of a tool. Knob with scale and index The plastic knob with scale and index enables the user to adjust the Aquastat on a selected temperature setting within its range. The knob fits on the cam and stays on it due to the force of the spring on the nave of the knob. This spring force enables the installer to pull the knob from the cam without the use of tools. The hole in the knob and the shaft of the cam are provided with a flat side which allows mounting of the knob only in one position in order to maintain the calibration. The plastic index will be fastened by means of two M4 thread forming screws on the housing. Adjustable differential On request, it is possible to deliver the Aquastat with an adjustable switch differential. The adjustable switch differential feature consists of a plastic adjusting dial with pointer, which is connected to a moveable contact. Turning of the dial changes the contact gap of the Micro Switch and thus the differential. The dial is situated under the front cover or behind the panel. Adjustable differential feature is only applicable on controllers and recycling limit controls Micro Switch The Micro Switch mechanism is also mounted into the plastic housing. the mechanism consists of a snap action spring type PL with contacts and a moveable or a fixed and a stationary contact bracket. EN2R-9005 0406R3-NE 2 DESCRIPTION The L41../L61.. series aquastats can be divided in the following main types: • Controller Controls the water temperature in accordance with the setting of an external knob (TÜV-type TR) • Recycling limit control Limits the water temperature below or above an adjusted level and resets automatically. This type has a greater differential and no external knob (TÜV-type TW). • Thermal cut-out with external reset button (manual reset) Limits the water temperature on a maximum adjusted level. This type does not reset automatically and it does not have an external knob. • Thermal cut-out with internal reset button (tool reset) Limits the water temperature on a maximum adjusted level. This type does not reset automatically and it does not have an external knob. The L41../L61.. series aquastats are sensitive water temperature control, which are provided with a liquid filled sensing system. The following main types are available: • Single, panel mount immersion Aquastat with remote bulb to select the most favourable position on a boiler or vessel. • Single, direct mounted immersion Aquastat with insulating cover to protect against accidential touching of live parts. • Dual, direct mounted immersion Dual Aquastat and consisting of two basic single units, which are mounted together and protected by one common cover and using one well for the two sensors. • Single, surface mounted The sensor of this type is to be mounted directly on the surface of a boiler or pipe in a heating system. The Aquastat mechanism is directly attached to this sensor. The L41../L61.. series aquastats are primarily designed for application on water filled heating systems and systems for hot water supply, mainly domestic use. 3 EN2R-9005 0406R3-NE OVERVIEW/SELECTION GUIDE Application Single Aquastat thermostats Controller or limiter thermostat Dual Aquastat thermostats Controller and limiter thermostat with standard sensing element Direct mount (immersion) L4188A, B, C 25 ... 95°C 40 ... 110°C 70 ... 140°C L6188A, B, C 25 ... 95°C 40 ... 110°C 70 ... 140°C L4189A, B, C 25 ... 95°C 40 ... 110°C 110 ... 230°F L6189A, B, C 25 ... 95°C 40 ... 110°C 70 ... 140°C 110 ... 230°F Panel mount (immersion) Surface mount (with mounting strap) L6190A, B, C 25 ... 95°C Replacement aquastat (immersion) L6188A 2044 40 ... 110°C EN2R-9005 0406R3-NE 4 L4191A, B and L6191A, B 25 ... 95°C 50 ... 95°C 40 ... 110°C 70 ... 140°C FEATURES • 6.3 mm quick connect terminals for receptacles • Mounting either in a horizontal or vertical position. • Housing is provided with two mounting holes which are suitable for M4 thread forming screws, for mounting on a control panel. • Cable entry in the conduit box is suitable for Pg 13.5 conduit or is provided with a plastic grommet (at choice). • The high and low setpoint stops are field adjustabe with steps of 2.5°C. • Capillary available in 350 mm (optional), 1000 mm (standard), 1500 mm (optional) and 2000 mm (optional) length. • Surface mounted Aquastat can be mounted on cylinders of 300 ... 460 mm diameter as well on pipes from 40 ... 150 mm diameter. • Wide range of well assemblies available. 5 EN2R-9005 0406R3-NE L4188 - L6188 SINGLE AQUASTAT - DIRECT IMMERSION APPLICATIONS AND ORDERING INFORMATION Application L4188 and L6188 are sensitive, immersion-type water temperature thermostats for controlling and limiting boiler water temperature in hydronic heating systems. The thermostat has a liquid-filled sensing element which fits into an immersion well (order separately) for direct mounting into a boiler, tank or other vessel. Ordering information O.S. number Application L4188A 2015 L4188A 2023 L4188A 2031 L4188B 2005 L4188B 2013 Controller Controller Controller Controller Controller Temperature range 25 ... 95°C 40 ... 110°C 25 ... 95°C 40 ... 110°C 25 ... 95°C L6188A 2002 Controller 25 ... 95°C L6188A 2010 Controller 40 ... 110°C L6188A 2028 Controller 25 ... 95°C L6188A 2036 Controller 70 ... 140°C L6188A 2044 Controller 40 ... 110°C L6188B 2000 Controller 25 ... 95°C L6188B 2018 Controller 70 ... 140°C L6188B 2026 Controller 40 ... 110°C L6188B 2034 Controller 25 ... 95°C L6188B 2042 L6188C 2008 L6188C 2016 Controller Limiter Limiter 25 ... 95°C 70 ... 140°C 25 ... 95°C Switch differential (K) 4 4 4 4 4 4 ... 10 (adjustable) 4 ... 10 (adjustable) 4 ... 10 (adjustable) 4 ... 10 (adjustable) 4 ... 10 (adjustable) 4 4 ... 10 (adjustable) 4 ... 10 (adjustable) 4 ... 10 (adjustable) 4 Manual reset Manual reset 1 = High limit stop 2 = High limit stop at 60°C 3 = Capilliary length 1500 mm and mounting bracket 4 = Without cover and conduit box 5 = Quick connect terminals only 6 = With well assembly 7 = With push-in plug EN2R-9005 0406R3-NE 6 Switch type Setting means SPST SPST SPST SPST SPST External knob External knob External knob Internal screw Internal screw Remarks (see notes) 5 5 4-5 4-5 SPDT External knob 6 SPDT External knob 6 SPDT External knob 3 SPDT External knob 6 SPDT External knob Tradeline 1 - 7 SPDT Internal screw 4 SPDT Internal screw 3-7 SPDT Internal screw SPDT Internal screw 6-7 SPDT SPDT SPDT Internal screw Internal screw Internal screw 7 6-7 L4188 - L6188 SINGLE AQUASTAT - DIRECT IMMERSION Specifications Immersion wells, see page 18 Ambient temperature limits 0 ... 70°C C 1 Electrical connection 6.3 mm spade terminals + 2 C 1 + Enclosure IP40 Electrical rating 10 A at 250 Vac, resistive load 2.5 A at 250 Vac, inductive load 15 A at 250 Vac, locked motor 250 mA at 30 mVdc (special option) SPST SPDT Fig. 1. Internal schematics L4188/L6188 Terminal data C-1 breaks on temperature rise (SPDT and SPST) C-2 makes on temperature rise (SPDT only) Accessories 14.6 11.5 5 48 47.1 85 32 9 2 1 C 72 30 14.4 14 48 4 21 Pg 13.5 48 Fig. 2. Dimensional drawing L4188/L6188 7 EN2R-9005 0406R3-NE L4189 - L6189 SINGLE AQUASTAT - PANEL MOUNTING (IMMERSION) APPLICATIONS AND ORDERING INFORMATION Application L4189 and L6189 are sensitive, immersion-type water temperature thermostats for controlling and limiting boiler water temperature in hydronic heating systems. These thermostats are designed for panel mounting and are supplied with a remote bulb and a liquid-filled sensing element which fits into an immersion well (order separately) for mounting into a boiler, tank or other vessel. Ordering information O.S. number Application L4189A 2006 L4189A 2014 L4189A 2089 L4189A 2097 L4189A 2105 L4189B 2012 L6189A 2001 L6189A 2019 Controller Controller Controller Controller Controller Controller Controller Controller Temperature range 25 ... 95°C 25 ... 95°C 25 ... 95°C 25 ... 95°C 25 ... 95°C 100 ... 230°F 25 ... 95°C 25 ... 95°C L6189A 2043 Controller 40 ... 110°C L6189A 2068 Controller 25 ... 95°C L6189A 2092 Controller 110 ... 230°F L6189A 2118 Controller 110 ... 230°F L6189A 2134 Controller 110 ... 230°F L6189A 2142 Controller 110 ... 230°F L6189A 2159 Controller 110 ... 230°F L6189B 2009 L6189B 2025 L6189B 2041 L6189C 2007 L6189C 2023 L6189C 2031 Controller Controller Controller Limiter Limiter Limiter 25 ... 95°C 25 ... 95°C 40 ... 110°C 40 ... 110°C 110 ... 230°F 110 ... 230°F Switch differential (K) 4 4 4 4 4 4 8 4 4 ... 10 (adjustable) 4 7 ... 18°F (adjustable) 15°F 7 ... 18°F (adjustable) 15°F 7 ... 18°F (adjustable) 4 4 8 Manual reset Manual reset Manual reset 1 = High limit stop 2 = Without knob and index 3 = With mounting bracket 4 = With conduit box 5 = With cable connector 6 = Low limit stop EN2R-9005 0406R3-NE 8 Switch type Setting means External knob External knob External knob External knob External knob Internal screw External knob External knob Capillary length (mm) 1000 1500 1000 1000 350 1000 1500 1500 Remarks (see notes) 2 1-4-5 5 1-6 3 2 - SPST SPST SPST SPST SPST SPST SPDT SPDT SPDT External knob 1500 - SPDT External knob 1000 2 SPDT External knob 1500 1 SPDT External knob 1500 1 SPDT External knob 1500 1 SPDT External knob 2000 1 SPDT External knob 2000 1 SPDT SPDT SPDT SPDT SPDT SPDT Internal screw Internal screw Internal screw Internal screw External knob External knob 1000 1000 1500 1500 1500 2000 2, Tradeline - L4189 - L6189 SINGLE AQUASTAT - PANEL MOUNTING (IMMERSION) SPECIFICATIONS AND DIMENSIONS Specifications Ambient temperature limits 0 ... 70°C Accessories Immersion wells, see page 18 Electrical connections 6.3 mm spade terminals C 1 + Enclosure IP40 Electrical rating 10 A at 250 Vac, resistive load 2,5 A at 250 Vac, inductive load 15 A at 250 Vac, locked motor 250 mA at 30 mVdc (special option) SPST 2 C 1 + SPDT Fig. 3. Internal schematics L4189/L6189 Terminal data C-1 breaks on temperature rise (SPDT and SPST) C-2 makes on temperature rise (SPDT only) Capilliary length 350 mm, 1000 mm, 1500 mm and 2000 mm Mounting hole (2) for M4x20 tread forming screw 17 32 16 60 48 2 mm max 47.1 48 18 32 2 Hole ( 4 min.) in panel for tool reset 1 C Panel 28.5 14.4 14 48 30.5 85 5 Fig. 4. Dimensional drawing L4189/L6189 9 EN2R-9005 0406R3-NE L6190 SINGLE AQUASTAT - SURFACE MOUNTING APPLICATION AND ORDERING INFORMATION Application The L6190 is a sensitive water temperature thermostat designed for surface mounting on domestic hot water cylinders or pipe work. The SPDT switching action is accomplished by a snap-action microswitch actuated by the temperature sensing element. The L6190 is supplied complete with mounting strap for rapid and easy installation. Draining of the system or tapping of the cylinder or pipe work is not required. The required temperature control point is easily set using a screw driver. Ordering information O.S. number Application L6190A 2016 L6190B 2006 L6190B 2014 L6190B 2022 Surface mounting Surface mounting Surface mounting Surface mounting Temperature range 25 ... 95°C 25 ... 95°C 25 ... 95°C 25 ... 95°C L6190B 2030 Surface mounting 25 ... 95°C L6190C 2004 L6190C 2012 Surface mounting Surface mounting 25 ... 95°C 25 ... 95°C EN2R-9005 0406R3-NE Switch differential (K) 8 8 12 4 4 ... 10 (adjustable) Manual reset Manual reset 10 Switch type Setting means SPDT SPDT SPDT SPDT External knob External setting External setting External setting Strap length (mm) 250 2000 2000 2000 SPDT Internal setting 250 SPDT SPDT Internal setting Internal setting 2000 2000 L6190 SINGLE AQUASTAT - SURFACE MOUNTING SPECIFICATIONS AND DIMENSIONS Specifications Ambient temperature limits 0 ... 70°C Capilliary length 55 mm Electrical connection 6.3 mm spade terminals or screw terminals 2 C 1 + Enclosure IP40 Electrical rating 10 A at 250 Vac, resistive load 2,5 A at 250 Vac, inductive load 15 A at 250 Vac, locked motor SPDT Fig. 5. Internal schematic L6190 Terminal data C-1 breaks and C-2 makes on temperature rise 48 24 26.5 66 12 72 100 92 9 30 51 24 Fig. 6. Dimensional drawing L6190 11 EN2R-9005 0406R3-NE L4191 - L6191 DUAL AQUASTAT - DIRECT IMMERSION APPLICATION AND ORDERING INFORMATION Application L4191 and L6191 are dual units in which two independently working water temperature thermostats are housed in one cover. Each thermostat has a separate liquid filled sensing element which fits into a common immersion well for direct mounting into a boiler, tank or other vessel. One thermostat, with external temperature setting dial, acts as a controller while the other, with internal setting dial, acts as a high limit control. Two main types are available, one with controller and auto recycling high limit and the other with controller and high limit with manual reset. Ordering information L4191 O.S. number L4191A 2002 L4191A 2010 L4191B 2018 L4191B 2042 Application Controller Limiter Controller Limiter Controller Limiter Controller Limiter Temperature range 25 ... 95°C 25 ... 95°C 25 ... 95°C 25 ... 95°C 70 ... 140°C 70 ... 140°C 25 ... 95°C 25 ... 95°C Switch differential (K) 4 4 4 4 4 Manual reset 4 Manual reset 1 =Gold contacts for thermocouple applications, without jumper 2 =High limit stop at 80°C/low limit stop at 60°C 3 =High limit stop at 82°C 4 =Low limit stop at 95°C 5 =Isolated neutral terminal 6 =High limit stop at 95°C Switch type Setting means SPST SPST SPST SPST SPST SPDT SPST SPDT External knob Internal screw External knob Internal screw External knob Internal screw External knob Internal screw Remarks (see notes) 9 9 7 - 9 - 10 9 6 1 5 - 9 - 10 9 - 10 7 =With well assembly 8 =High limit stop 9 =With jumper 10 =With push-in plug 11 =Without knob and index Ordering information L6191 O.S. number L6191A 2007 L6191A 2015 L6191A 2023 L6191B 2005 L6191B 2013 L6191B 2021 L6191B 2047 L6191B 2054 Application Temperature range Controller 40 ... 110°C Limiter Controller Limiter Controller Limiter Controller Limiter Controller Limiter 40 ... 110°C 25 ... 95°C 101°C fixed 50 ... 95°C 101°C fixed 25 ... 95°C 40 ... 110°C 40 ... 110°C 40 ... 110°C Controller 70 ... 140°C Limiter 70 ... 140°C Controller 70 ... 140°C Limiter Controller Limiter 70 ... 140°C 25 ... 95°C 50 ... 95°C Switch differential (K) 4 ... 10 (adjustable) 4 4 4 4 4 4 Manual reset 4 Manual reset 4 ... 10 (adjustable) Manual reset 4 ... 10 (adjustable) Manual reset 4 Manual reset 1 =Gold contacts for thermocouple applications, without jumper 2 =High limit stop at 80°C/low limit stop at 60°C 3 =High limit stop at 82°C 4 = Low limit stop at 95°C 5 = Isolated neutral terminal 6 = High limit stop at 95°C EN2R-9005 0406R3-NE Switch type Setting means Remarks (see notes) SPDT External knob 6-7-9 SPDT SPDT SPST SPDT SPST SPDT SPDT SPDT SPDT Internal screw External knob Internal setting External knob Internal screw External knob Internal screw External knob Internal screw 9 3 1 3 1 7 - 9 - 10 9 5-6-7-9 9 SPDT External knob 4-7-9 SPDT Internal screw 9 SPDT External knob 4 - 7 - 9 - 11 SPDT SPDT SPDT Internal screw External knob Internal screw 9 7 - 10 7 = With well assembly 8 = High limit stop 9 = With jumper 10 =With push-in plug 11 = Without knob and index 12 L4191 - L6191 DUAL AQUASTAT - DIRECT IMMERSION SPECIFICATIONS AND DIMENSIONS Specifications Ambient temperature limits 0 ... 70°C C 1 C 1 Electrical connection 6.3 mm spade terminals + + C 1 2 C 1 + + Enclosure IP40 Electrical rating: 10 A at 250 Vac, resistive load 2,5 A at 250 Vac, inductive load 15 A at 250 Vac, locked motor 250 mA at 30 mVdc (special option) SPST SPST Control Limit 2 C 1 C 1 Terminal data C-1 breaks on temperature rise C-2 makes on temperature rise + + SPST Control SPDT Limit 2 C 1 2 C 1 + + Accessories Immersion wells, see page 18 SPDT Control SPDT Limit SPDT Control SPDT Control Fig. 7. Internal schematics 14.6 11.5 ϕ5 ϕ 47.1 85 72 4 ϕ 21 Pg 13.5 30 84 48 Fig. 8. Dimensional drawing L4191/L6191 13 EN2R-9005 0406R3-NE L6188A 2044 TRADELINE SINGLE AQUASTAT - DIRECT IMMERSION APPLICATIONS AND ORDERING INFORMATION Application L6188A 2044 Tradeline Aquastat is a sensitive immersion-type water temperature thermostat for regulating and limiting boiler water temperature in hydronic heating systems. The Honeywell Tradeline technique of using adapters enables the L6188A 2044 Aquatat thermostat to field replace Honeywell Aquastat thermostats as well as many competitive devices (using the existing well*). No draining of the system is needed. Ideal for service organisations to stock since only one Aquastat is needed for most calls. * If a new immersion well is needed order separately. Ordering information L6188A 2044 O.S. number Application Temperature range L6188A 2044 Controller 40 ... 110°C Switch differential (K) 4 ... 10 (adjustable) 1 = High limit stop at 95°C/low limit stop at 50°C EN2R-9005 0406R3-NE 14 Switch type Setting means Remarks (see notes) SPDT External knob 1 L6188A 2044 TRADELINE SINGLE AQUASTAT - DIRECT IMMERSION SPECIFICATIONS AND DIMENSIONS Specifications Temperature range 40 ... 110°C Accessories Immersion wells, see page 18 Differential 4 ... 10 (adjustable) 2 C 1 + Limit stops: Low limit: adjustable, factory set at 50°C High limit: adjustable, factory set at 95°C Ambient temperature limits 0 ... 70°C SPDT Electrical connection 6.3 mm spade terninals Fig. 9. Internal schematic Enclosure IP40 Electrical rating 10 A at 250 Vac, resistive load 2,5 A at 250 Vac, inductive load 15 A at 250 Vac, locked motor Terminal data C-1 breaks on temperature rise C-2 makes on temperature rise 14.6 11.5 5 48 47.1 85 32 9 2 1 C 72 30 14.4 14 48 4 21 Pg 13.5 48 Fig. 10. Dimensional drawing L6188A 2044 15 EN2R-9005 0406R3-NE PERFORMANCE Ambient temperature error Fixed switch differential On controls and recycling limits a fixed differential of: 4 ± 1.5°C, 8 ± 3°C or 12 ± 3°C is supllied as a standard. Ratio of ambient error With capilliary lenth of 1000 mm With capilliary lenth of 50 mm Optional are: 7 ± 2.7°F, 14 ± 5.4°F 15 ± 5.4°F Time constant • With well τ ≤ 30 s for panel mounted, single direct mounted, dual direct mounted and triple direct mounted Aquastats. • Without well τ≤4s • With sensor assy (Surface mounted Aquastat) τ ± 50 s Manual or tool reset switch differential On the thermal cut-out versions (manual or tool reset) of the panel mounted, the single direct mounted and the dual direct mounted Aquastats the maximum reset differential might be 30°C Setpoint accuracy +0/-8°C for thermal cut-outs The differential (thermal) is dependant on the rate of change of the temperature in the heating system. The given differential datas are valid for a rate of 1°C per minute. EN2R-9005 0406R3-NE Min. setting 1 : 8.5 1 : 25 Example: An ambient error ratio of 1 : 6 means that an ambient change of 6°C will cause a setpoint shift of the Aquastat of 1°C. Adjustable switch differential On controllers and recycling limiters an adjustable differential of: 4 ± 1.5°C ... 10 ± 3°C or 7 ± 2.7°F ... 18 ± 5.4°F can be supllied. NOTE: Max. setting 1 : 5.5 1 : 12 16 CONSTRUCTION Dual direct mounted Aquastat needs the following extra parts • Two single thermoplastic conduit boxes (a right and a left one) with cable entry. • A dual thermoplastic front cover to protect against touching of live parts. • A thermoplastic top cover for covering of units with internal setting. • An adjustable dial for the Micro Switch differential (if applicable). • A bracket on the rear side of the Aquastat to connect both basic units together and which fits into a dual well. All aquastats have the following common parts • Thermoplastic housing of mainly rectangular form. This housing is the carrier of the Micro Switch mechanism, the 6.3 mm quick connect terminals, the lever mechanism and the adjusting mechanism. • Thermoplastic switch cover, which protects the switch mechanism and which fits in the above mentioned housing. • Auxiliary parts to make it possible to use the quick connect terminals also for screw connection. • External circular setting knob with scale and an index or internal setting with scale. • Liquid filled sensing element with or without a remote bulb. This element is via a mounting plate connected to the rear side of the thermoplastic housing • Well assembly in which the bulb of the sensing elements fits. For the dual direct mount aquastat and triple direct mount aquastat the well is enable to contain two resp. three bulbs. NOTE: The surface mounted Aquastat does not have a well, but the bulb is enveloped by a sensor assembly of mainly rectangular form which is mounted on the rear side of the thermoplastic housing. • A reset button for the switch mechanism, manual or tool reset, with exception of the surface mounted Aquastat, which does not have such a button. Surface mounted Aquastat needs the following extra parts • A thermoplastic conduit box with a cable entry • A thermoplastic front cover to protect against touching of live parts. • A thermoplastic top cover with scale for covering of unit with internal setting. • A fastening strap with fastener, to mount the Aquastat on the surface of boiler or pipe. Triple direct mounted Aquastat needs the following extra parts • Three single thermoplastic conduit boxes with a cable entry. • A dual and a single thermoplastic front cover. • Two thermoplastic top covers for covering of units with internal setting. • An adjustable dial for the Micro Switch differential (if applicable). • Two brackets on the rear side of the Aquastat to connect the three basic units together and which fits into a triple well. Single direct mounted Aquastat needs the following extra parts • A thermoplastic conduit box with a cable entry. • A thermoplastic front cover to protect against touching of live parts. • A thermoplastic top cover for covering of units with internal setting. • An adjustable dial for the Micro Switch differential (if applicable). 17 EN2R-9005 0406R3-NE ACCESSORIES AND SPARE PARTS Single well assembly Description Ordernumber Spud thread: 1/2” BSPT Maximum insertion length (including thread): 105 mm Suitable for Ø 5 mm sensor Spud thread: 1/2” BSPT Maximum insertion length (including thread): 170 mm Suitable for Ø 5 mm sensor 45.900.409-003 Packing qty (pcs) 40 45.900.409-006 100 Description Ordernumber Spud thread: 1/2” BSPT Maximum insertion length (including thread): 105 mm Suitable for two Ø 5 mm sensors. 45.900.409-007 Packing qty (pcs) 20 Spud thread: 1/2” BSPT Maximum insertion length (including thread): 105 mm Suitable for two Ø 5 mm sensors when used with spring. Without spring suitable for three or four Ø 5 mm sensors. Supplied with spring 45.900.409-008 20 Dual well assembly EN2R-9005 0406R3-NE 18 Miscellaneous Description Knob assembly Scale range: 110 ... 230°F, high limit stop: 180°F Knob assembly Scale range: 40 ... 110°C, high limit stop: 82°C Strap set for L6190 surface mounted aqustat Strap length: 2000 mm Key number 1 2 3 4 5 6 7 Ordernumber Packing qty (pcs) 45.900.427-002 200 45.900.427-003 200 45.900.443-001 50 Description Part number Fixing screw for front covers of single and dual aquastats Knob Scale range Low limit stop High limit stop 40 ... 110°C 70 ... 140°C 25 ... 95°C 40 ... 110°C 95°C 70 ... 140°C 95°C 40 ... 110°C 50°C 95°C 25 ... 95°C 82°C 40 ... 110°C 100°C 25 ... 95°C 60°C 70 ... 140°C 95°C 25 ... 95°C 60°C 80°C 1 ... 7 (40 ... 110°C) 85°C 50 ... 95°C 82°C 40 ... 110°C 82°C 25 ... 95°C 40°C 80°C 80 ... 100°F 110 ... 230°F 160 ... 280°F 110 ... 230°F 200°F 110 ... 230°F 180°F Cover for single Aquastat Screw Wire clamp Conduit box Push in plug 45.002.700-001 19 45.002.823-001 45.002.823-002 45.002.823-003 45.002.823-004 45.002.823-005 45.002.823-006 45.002.823-007 45.002.823-008 45.002.823-010 45.002.823-011 45.002.823-013 45.002.823-014 45.002.823-015 45.002.823-017 45.002.823-019 45.004.213-001 45.004.213-002 45.004.213-003 45.004.213-004 45.004.213-005 45.002.547-002 45.000.219-015 45.002.797-001 45.002.540-001 45.002.802-001 EN2R-9005 0406R3-NE QUALITY ASSURANCE STATEMENT Products are manufactured under an ISO 9001 (1994) based and certified Quality System. Assembly processes are guided by work instructions. Patrol inspections form part of the assembly processes. The quality system is described in the Honeywell Combustion Controls Center Quality Assurance Programme and its related operational procedures and instructions. At the end of the assembly phase, all aqustats are leakage and performance tested/adjusted. Assembly inspection is performed by employees of the quality control department, using their own equipment. The quality system is approved by Gastec against certificate number 9.302/2. All inspections (incoming and assembly) are performed by trained personel and according inspection procedures. The quality organisation is responsible for defining, maintaining, improving and verification of the quality systems in the field of design, production process and field quality service. STANDARDS AND APPROVALS Standards Approvals The L41../L61.. series Aquastats have been designed according the Low Voltage Directive 73/23/EEC. An additional approval is obtained from DIN in Germany according to DIN 3440 as thermostat (TR) or temperature limiter (TW). This Low Voltage Directive is covered by approvals in Denmark, Finland, Norway, Sweden and Switserland. In North-America approvals have been obtained from UL, AGA and CSA. EMC Directive 89/336/EEC: The snap action switch ensures in most cases a switching action in less than 10 ms, which satisfies EMC-Directive without further measures. The exception is a highly inductive low current load combined with slow rate of temperature change, which requires additional suppression means. For this reason compliance with the EMC-Directive cannot be claimed. Europen countries accept above certificates as basis for appliance approval. EN2R-9005 0406R3-NE 20 ORDERING INFORMATION When ordering specify • Setting point(control and limit if necessary) • Type of contact (SPDT/SPST/ electrical rating) • Number of sensing point (single/dual) • Type of mounting (direct immersion/panel/surface) • Differential (adjustable/fixed/manual reset) • Capillary length Ordering Specification number L 4 1 X X A 9999 L: Aquastat Specification number Control contact: 4: SPST 6: SPDT A: Single: Dual: B: Single: Dual: C: Single: 1: Family 88: 89: 90: 91: 92: knob setting automatic reset limiter internal setting (screw) manual reset limiter manual reset Single aquastat, direct immersion Single aquastat, panel mounting Single aquastat, surface mounting Dual aquastat, direct mounting Triple aquastat, direct mounting Fig. 11. Model number chart 21 EN2R-9005 0406R3-NE Home and Building Control Combustion Control Center Europe Honeywell BV Phileas Foggstraat 7 7821 AJ Emmen The Netherlands Tel.: +31 (-)591 695911 Fax: +31 (-) 591 695200 http://europe.hbc.honeywell.com EN2R-9005 0406R3-NE 22