Specification AXIOM5050M Oscillator type: Low Phase Noise

Specification
Oscillator type:
Rev.: 1
Date: 2014-06-20
AXIOM5050M
Low Phase Noise OCXO with Multiple Outputs
Parameter
Frequency range
Frequency stability
Initial tolerance @ +25°C
vs. operating temperature range
vs. supply voltage variation (pushing)
vs. load change (pulling)
Long term (aging) per day
st
Long term (aging) 1 year
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
RF output ports (Note 2)
Signal waveform
Load RL
Output level (each port)
Isolation between RF ports
Harmonics
Spurious
Warm-up time @ +25°C
Phase noise
Supply voltage VS (Note 4)
Current consumption (steady state)
Current consumption (warm-up)
Enclosure (see drawing) (LxWxH)
Weight
Packing
Notes:
1.
2.
3.
4.
min. typ. max. Unit
96.000,mnbnbbn,
50
150 MHz
±300
Option 2 & 3
See tables 1 & 2
±10
±5
±1
±2
±100
±200
±1
0
±2
5.0
Positive
10.0
100
Condition
ppb
@ VC = 5.0 V
steady state
ppb
ppb
ppb
ppb
VS ±5%
RL ±5%
after 30 days operation
after 30 days operation
ppm
V
kΩ
2, 4, 6
Sine wave
50
Option 1
Ω
dBm
dB
dBc
dBc
min
+5
30
11.4
-30
-90
3
5
Consult factory
12.0
12.6 V
300 mA
500 mA
50.0x50.0x21.0 max.
60
Palette
±5%
(Note 3)
∆ffinal/f0 < ±0.1 ppm
@ +25°C
mm
g
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated
Odd number of ports on request
Higher output level on request. Unused ports must be terminated with 50 Ω
Other supply voltage on request
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-55
VS + 10%
15
+125
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM5050M Rev.1
Drawing D0
Page 1(4)
Unit
Condition
V
V
°C
VS to GND
VC to GND
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Frequency stability vs. temperature
Stability
[ppb]
±5
±10
±25
±50
±100
±200
Option 2
05
10
25
50
100
200
Table 1
Temperature
range [°C]
05
0 ~ +50
O
-10 ~ +60
O
-20 ~ +70
O
-30 ~ +70
O
-40 ~ +75
-40 ~ +85
-55 ~ +85
Table 3 “Availability”
Lower Temperature
Option 3
T [°C]
0
0
1
-10
2
-20
3
-30
4
-40
5
-55
Table 2
10
X
X
X
O
O
-
Upper Temperature
Option 3
T [°C]
A
+50
B
+60
C
+70
D
+75
E
+80
F
+85
Standard: “1B” = -10°C to +60°C
Frequency stability [Option 2]
25
50
100
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O
X
X
O
X
X
200
X
X
X
X
X
X
X
X = available, O = available on request, - not available
Ordering Code
Option 1
Option 2
Option 3
[Output ports]
[Stability]
[Temperature range]
AXIOM5050M
2, 4, 6
Table 1
Table 2
Example: AXIOM5050M-6-25-1B_Rev.1 – 100.000 MHz
Model
Handling and Testing
Parameter
Handling and Testing
Processing
Parameter
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS- Compliant
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Revision
Frequency [MHz]
Rev.1
100.000
Procedure
Application Note AXAN-011
Application Note AXAN-012
Procedure
IEC60749-26
IEC60749-27
Yes
Yes
AXIOM5050M Rev.1
Drawing D0
Page 2(4)
HBM
MM
No
No
Source
www.axtal.com
www.axtal.com
Condition
2000 V
200 V
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections:
Pin #
Symbol Function
1
VS
Supply Voltage
2
GND Ground
3
VC
Control Voltage (EFC)
SMA (6x) RF OUT RF Outputs
Ports
2
4
6
SMA Connectors *
SMA S3 – S4
SMA S2 – S5
SMA S1 – S6
*Unused connectors are not present
* See Application Note AXAN-011
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM5050M Rev.1
Drawing D0
Page 3(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
2-58
5.6.3
208H
210F
2-27
5.6.8
213B
Vibration,
2-6
5.6.7.1
201A
sinusoidal*
204D
Vibration,
2-64
5.6.7.3
214A
random*
Endurance tests
108A
- ageing
5.7.1
- extended aging
5.7.2
Other environmental conditions on request
MIL-STD810F
Method
MIL-PRF55310D
Clause
3.6.1.2
3.6.52
3.6.48
516.4
3.6.40
516.4-4
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
514.5
4.8.35
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Td1 Method 2
Test Td2 Method 2
Test Ea, 3 x per axes 100g,
6 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Fdb
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice.
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
Remarks
Author
Checked
1
D0
20.06.2014
First issue
HH
HH
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM5050M Rev.1
Drawing D0
Page 4(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836