Designed and Manufactured in Germany Specification Oscillator type: Rev.: 6 Date: 2014-04-18 AXIOM25 OCXO in DIL14 Package with Sine Wave Output Parameter Frequency range Standard frequencies Frequency stability Initial tolerance @ +25°C vs. operating temperature range vs. supply voltage variation (pushing) vs. load change (pulling) Long term (aging) per day (after 30 days operation) (Note 2) st Long term (aging) 1 year (after 30 days operation) (Note 2) Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load RL Output level (Note 3) Harmonics Warm-up time @ +25°C Phase Noise Supply voltage VS Current consumption (steady state) @ +25°C (Note 4) Current consumption (warm-up) (Note 4) Enclosure (see drawing) (LxWxH) Weight Packing Notes: 1. 2. 3. 4. min. typ. max. Unit Condition 10 125 MHz 10.000/20.000/80.000/100.000 MHz ±500 ppb VC @ centre value steady state ±10 ±20 ±10 ±2 ±500 ±200 ppb ppb ppb ppb ppb ppb VS ±5% RL ±10% AT-Cut SC-Cut AT-Cut SC-Cut ±5 ppm ppm V V AT-Cut SC-Cut Option 1 = “33” Option 1 = “50”, “12” Option 2 & 3 See tables 1 & 2 ±300 ±100 ±2 ±1 0.15 0.25 1.65 2.50 Positive 3.15 4.75 100 kΩ Sine wave 50 +3 3.15 4.75 11.4 -25 2 Consult factory 3.3 3.45 5.0 5.25 12.0 12.6 300 200 100 700 500 200 20.7x13.1x8.5 max. 5 Ω dBm dBc min ±10% ∆ffinal/f0 < ±0.1 ppm V V V mA mA mA mA mA mA Option 1 = “33” Option 1 = “50” Option 1 = “12” Option 1 = “33” Option 1 = “50” Option 1 = “12” Option 1 = “33” Option 1 = “50” Option 1 = “12” mm g IEC 60679-3 CO 02 Palette or Tube Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Lower aging on request Other output level on request May be higher for wide operating temperature range GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM25 Rev.6 Drawing D0 Page 1(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -55 VS + 10% 15 +125 Unit Condition V V °C VS to GND VC to GND Frequency stability vs. temperature Option 2 05 10 25 50 100 200 Table 1 Stability [ppb] ±5 ±10 ±25 ±50 ±100 ±200 Lower Temperature Option 3 T [°C] 0 0 1 -10 2 -20 3 -30 4 -40 5 -55 Table 2 Upper Temperature Option 3 T [°C] A +50 B +60 C +70 D +75 E +80 F +85 Standard: “1B” = -10°C to +60°C Temperature Frequency stability [Option 2] range [°C] 05 10 25 50 100 200 0 ~ +50 O O SC AT AT AT -10 ~ +60 O O SC AT AT AT -20 ~ +70 O O SC SC AT AT -30 ~ +70 O O SC SC SC AT -40 ~ +75 O O O SC SC SC -40 ~ +85 O O O SC SC SC -55 ~ +85 O O O SC SC Table 3 “Availability” AT, SC = AT-Cut, SC-Cut available, O = available on request, - not available Ordering Code Option 1 Option 2 Option 3 [Supply Voltage] [Stability] [Temperature range] AXIOM25 12, 33, 50 Table 1 Table 2 Example: AXIOM25-50-100-1B_Rev.6 – 10.000 MHz Model GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM25 Rev.6 Drawing D0 Page 2(4) Revision Frequency [MHz] Rev.6 10.000 www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Enclosure drawing Pin connections Pin # 1 7 8 14 Symbol VC GND RF OUT VS Function Control Voltage (EFC) Ground RF Output Supply Voltage * See Application Note AXAN-011 Handling and Testing Parameter Procedure Handling and Testing Processing Parameter Application Note AXAN-011 Application Note AXAN-012 Procedure Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS compliant GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany IEC60749-26 IEC60749-27 Yes Yes AXIOM25 Rev.6 Drawing D0 Page 3(4) HBM MM No No Source www.axtal.com www.axtal.com Condition 2000 V 200 V www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] 5 6 D0 D0 11.10.2013 18.04.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Major revision Frequency range extended, various parameters updated, environmental conditions updated, editorial changes AXIOM25 Rev.6 Drawing D0 Page 4(4) Author Checked CG HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]