Designed and Manufactured in Germany Specification Oscillator type: Rev.: 8 Date: 2014-04-18 AXIOM45 High Stability Eurocase OCXO with Sine Wave Output Parameter Frequency range Standard frequencies Frequency stability Initial tolerance @ +25°C vs. operating temperature range vs. supply voltage variation (pushing) vs. load change (pulling) Long term (aging) per day (after 30 days operation) (Note 2) st Long term (aging) 1 year (after 30 days operation) (Note 2) Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load RL Output level (Note 3) Harmonics Warm-up time @ +25°C Phase Noise Reference voltage VREF output (Note 4) Supply voltage VS Current consumption (steady state) @ +25°C (Note 5) Current consumption (warm-up) (Note 5) Enclosure (see drawing) (LxWxH) (Note 6) Weight Packing Notes: 1. 2. 3. 4. 5. 6. min. typ. max. Unit Condition 5 125 10.000/20.000/100.000 MHz MHz ±300 ppb VC @ VREF/2 steady state ±10 ±10 ±10 ±2 ±500 ±200 ppb ppb ppb ppb ppb ppb VS ±5% RL ±10% AT-Cut SC-Cut AT-Cut SC-Cut ±5 ppm ppm V AT-Cut SC-Cut Option 2 & 3 See tables 1 & 2 ±300 ±50 ±2 ±0.8 0 VREF/2 Positive VREF 100 kΩ Sine wave 50 +3 4.75 11.4 -25 3 5 Consult factory 4.0 5.0 5.0 5.25 12.0 12.6 250 150 600 350 36.1x27.2x16 max. 25 Ω dBm dBc min ±10% V V V V mA mA mA mA Option 1 = “50” Option 1 = “12” Option 1 = “50” Option 1 = “12” Option 1 = “50” Option 1 = “12” Option 1 = “50” Option 1 = “12” mm g IEC 60679-3 CO 08 ∆ffinal/f0 < ±0.1 ppm Palette Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Lower aging on request Other output level on request Other reference voltages on request May be higher for wide operating temperature range Lower height H available on request GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM45 Rev.8 Drawing D0 Page 1(4) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -55 VS + 10% 15 +125 Unit Condition V V °C VS to GND VC to GND Frequency stability vs. temperature Option 2 05 10 25 50 100 200 Table 1 Stability [ppb] ±5 ±10 ±25 ±50 ±100 ±200 Lower Temperature Option 3 T [°C] 0 0 1 -10 2 -20 3 -30 4 -40 5 -55 Table 2 Upper Temperature Option 3 T [°C] A +50 B +60 C +70 D +75 E +80 F +85 Standard: “1B” = -10°C to +60°C Temperature Frequency stability [Option 2] range [°C] 05 10 25 50 100 200 0 ~ +50 SC SC SC AT AT AT -10 ~ +60 SC SC SC AT AT AT -20 ~ +70 SC SC SC SC AT AT -30 ~ +70 O SC SC SC SC AT -40 ~ +75 O O SC SC SC SC -40 ~ +85 O O SC SC SC SC -55 ~ +85 O O SC SC SC Table 3 “Availability” AT, SC = AT-Cut, SC-Cut available, O = available on request, - not available Ordering Code Option 1 Option 2 Option 3 [Supply Voltage] [Stability] [Temperature range] AXIOM45 12, 50 Table 1 Table 2 Example: AXIOM45-12-10-1B_Rev.8 – 10.000 MHz Model GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIOM45 Rev.8 Drawing D0 Page 2(4) Revision Frequency [MHz] Rev.8 10.000 www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Enclosure drawing Pin connections Pin # 1 2 3 4 5 Symbol VC VREF VS RF OUT GND Function Control Voltage (EFC) Reference Voltage Supply Voltage RF Output Ground * See Application Note AXAN-011 Handling and Testing Parameter Handling and Testing Processing Parameter Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS- Compliant GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Procedure Application Note AXAN-011 Application Note AXAN-012 Procedure IEC60749-26 IEC60749-27 Yes Yes AXIOM45 Rev.8 Drawing D0 Page 3(4) HBM MM No No Source www.axtal.com www.axtal.com Condition 2000 V 200 V www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Designed and Manufactured in Germany Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] 7 8 D0 D0 14.10.2013 18.04.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Major revision Frequency range extended, various parameters updated, environmental conditions updated, editorial changes AXIOM45 Rev.8 Drawing D0 Page 4(4) Author Checked CG HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]