TECHNICAL DATA
100mA, Quasi Low-Dropout Voltage Regulator
IL3480
Features:
 3.3, 5V versions available
 30V maximum input for operation
 1.2V guaranteed maximum dropout over full load and
temperature ranges
 100 mA guaranteed minimum load current
Application:
Tiny alternative to 78LXX series and similar devices
Low-Dropout Voltage Regulator
● Post regulator for switching DC/DC converter
● Bias supply for analog circuits
●
●
ORDERING INFORMATION
Device
IL3480LF
Package
TO-92
Shipping
Tape
Typical Application Circuit
IL3480-3.3
Absolute Maximum Ratings
Input Voltage
Junction Temperature
35V
+150°C
* Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these or any other conditions beyond those
indicated under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
2011, February, Rev. 01
IL3480
Electrical Characteristics IL3480-3.3, IL3480-5.0
Typicals and limits appearing in normal type apply for T A = TJ = 25°C. Limits appearing in boldface type apply over the
entire junction temperature range for operation, -10 to +70°C. (Notes 1, 2)
Nominal Output Voltage (VNOM)
Parameter
Output Voltage
Line Regulation
Load Regulation
Symbol
3.3V
5.0V
Conditions
Min
Typ
Max
Min
Vout
Vin=Vnom+1.5V;
1mАIout100mА
3.17
3.14
3.3
3.43
3.46
4.8
4.75
Vout
Vnom+1.5V Vin30V;
Iout =1mA
Vout
Ground Pin Current
IGND
Ground Pin Current
Change
IGND
Vin=Vnom+1.5V;
1mАIout100mА
Vin=30V
No Load
Vnom+1.5V Vin20V,
Iout =40mA;
Vin=Vnom+5V,
1mАIout40mА
3
Typ
5.0
Max
5.2
5.25
25
25
40
50
4
1.4
3
4
1.4
Units
V
mV
mV
mA
mА
0.5
0.5
mА
0.9
0.9
Iout =10mA;
Dropout Voltage
Vin1.0
1.0
V
Vout
1.1
1.1
Iout =100mA
1.2
1.2
Note 1: A typical is the center of characterization data taken with TA = TJ = 25°C. Typicals are not guaranteed.
Note 2: All limits are guaranteed. All electrical characteristics having room-temperature limits are tested during
production with TA = TJ = 25°C. All hot and cold limits are guaranteed by correlating the electrical characteristics to