IKSEMICON IL3480

TECHNICAL DATA
100mA, Quasi Low-Dropout Voltage Regulator
IL3480
Features:
●
3.3, 5V versions available
30V maximum input for operation
1.2V guaranteed maximum dropout over full load and temperature ranges
● 100 mA guaranteed minimum load current
●
●
Application:
Tiny alternative to 78LXX series and similar devices
Low-Dropout Voltage Regulator
● Post regulator for switching DC/DC converter
● Bias supply for analog circuits
●
●
Typical Application Circuit
IL3480-3.3
Absolute Maximum Ratings
Input Voltage
Junction Temperature
35V
+150°C
Rev. 00
IL3480
Electrical Characteristics IL3480-3.3, IL3480-5.0
Typicals and limits appearing in normal type apply for TA = TJ = 25°C. Limits appearing in boldface type apply over the entire
junction temperature range for operation, -10 to +70°C. (Notes 1, 2)
Nominal Output Voltage (VNOM)
Parameter
Output Voltage
Line Regulation
Load Regulation
Symbol
5.0V
Conditions
Min
Typ
Max
Min
Vout
Vin=Vnom+1.5V;
1mА≤Iout≤100mА
3.17
3.14
3.3
3.43
3.46
4.8
4.75
ΔVout
Vnom+1.5V ≤Vin≤30V;
Iout =1mA
ΔVout
Ground Pin Current
IGND
Ground Pin Current
Change
ΔIGND
Dropout Voltage
3.3V
VinVout
Vin=Vnom+1.5V;
1mА≤Iout≤100mА
Vin=30V
No Load
Vnom+1.5V ≤Vin≤20V,
Iout =40mA;
Vin=Vnom+5V,
1mА≤Iout≤40mА
Iout =10mA;
Iout =100mA
3
Typ
5.0
Max
5.2
5.25
25
25
40
50
4
3
Units
4
V
mV
mV
mA
1.4
1.4
mА
0.5
0.9
1.0
1.1
1.2
0.5
0.9
1.0
1.1
1.2
mА
V
Note 1: A typical is the center of characterization data taken with TA = TJ = 25°C. Typicals are not guaranteed.
Note 2: All limits are guaranteed. All electrical characteristics having room-temperature limits are tested during production with TA = TJ = 25°C. All
hot and cold limits
are guaranteed by correlating the electrical characteristics to process and temperature variations and applying statistical process control.
Rev. 00
IL3480
• TO-92
Rev. 00