0664D SERIES The 664D filter is a 3 phase (Delta) filter. This series is designed to be used with military systems which are required to meet the conducted emission levels of MIL-STD-461, CE03. Minor modifications can be done to adjust the Environmental and vibration specs. Calculated MTBF, FR = 2.389477 = 418505 hours @ 30oC GB calculated Operating Voltage = 250/480 V ac Operating Current Max= 7 & 1 0 amps Operating Frequency = 50 - 400Hz Operating Temperature= -20 to +50oC Diel Withstand ( L to Case)= 1 500V ~for 1 Min. Diel Withstand ( L to L )= 1 500V dc for 1 Min. Leakage current @ 250V ~60Hz= 1.0 mA at 250V ac, 400Hz Max Residual Voltage after 5 secs = 34 V olts Max USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884