1138 SERIES The 1138 series is a 3 phase (WYE) filter. LOAD LINE This series is designed to be used with military systems which are required to meet the conducted emissions of MIL STD-461C. The filter is potted and constructed to meet shock and vibration requirements. Minor modifications can be done to adjust the filter configuration in order to meet any special customer specifications. Ordering Information 10 Amp: CC-1138-10 15 Amp: CC-1138-15 L1 1 1 2 2 3 3 N N GRD GRD INSERTION LOSS vs FREQUENCY 1138 SERIES Operating Voltage = __________250/480 V~, 50 / 60 Hz Operating Voltage = ________ 125/208 V~, 50 – 400 Hz Operating Current = _____________10, 15 Amp / Phase Temperature Range = __________________-20 to 50°C 90 INSERTION LOSS (db) 80 Diel. Withstand (L-Case) = _________1500 V~ for 1 Min. Diel. Withstand (L-L) = ___________1500 Vdc for 1 Min. Leakage Current = __________3.8 mA @ 250 V~, 60 Hz Discharge Volt after 1.0 sec. = ____________ 24 V Max. DM 70 60 50 40 CM-10 CM 30 20 Maximum Capacitance each line to case = ____ 0.02 µF 10 0 Calculated MTBF = _________ 639,736 Hrs GB @ 30°C .01 .04 .02 .1 .07 .4 .2 1 .7 4 2 10 7 40 20 6.79 6.39 1.82 .169 DIA (6 PL) 6.00 2.362 5.51 2.362 0.52 USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow, Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44 (0) 7785-310729 FX: 44 (0) 1415-891884 100 70