PDF Version - Aries Electronics, Inc.

ARIES ELECTRONICS, INC.
PRODUCTION DEPARTMENT
PROCEDURE NUMBER: A-548
REV. B
PROCEDURE NAME: CLEANING PROCEDURE FOR RF MICROSTRIP SOCKETS
OPERATOR:
OPERATOR / TECHNICIAN
PAGE 1 OF 1
****************************************************************************************************
AUTHOR: BRUCE DECHILLO
APPROVED BY: MJS
RELEASE DATE: June 8, 2006
****************************************************************************************************
1.0
1.1
SCOPE
THE PURPOSE OF THIS DOCUMENT IS TO DEFINE THE ACCEPTED CLEANING PROCEDURE
FOR ARIES’ RF MICROSTRIP SOCKETS.
2.0
2.1
2.2
2.3
REFERENCE DOCUMENTS
ARIES’ DATA SHEET 24001
RDZ-1699 DE-OX II DATA SHEET
RDZ-1699 DE-OX II MATERIAL SAFETY DATA SHEET
RD CHEMICAL, 1350 PEAR AVENUE, MOUNTAIN VIEW, CA 94043
PH: 650/962-8004, EMAIL: [email protected], WEB: www.rdchem.com
3.0
3.1
3.2
3.3
MATERIAL REQUIRED
MICROSTRIP SOCKET
ISOPROPYL ALCOHOL
RDZ-1699 DE-OX II
4.0
4.1
4.2
4.3
4.4
4.5
4.6
EQUIPMENT REQUIRED (OR EQUIVALENT)
B&L STEREOZOOM 4 MICROSCOPE (IF NEEDED)
TWEEZER
SMALL STAINLESS STEEL CONTAINER OR GLASS BEAKER
HOT PLATE
FIRM-HAIRED SCRATCH BRUSH
EXACTO KNIFE
5.0
5.1
PROCEDURE
CAUTION: BE CERTAIN TO HANDLE RDZ-1699 DE-OX II ACCORDING TO MANUFACTURERS
MSDS.
NOTE: DO NOT PUSH ON THE MICROSTRIP CONTACTS, OR LATCH THE LID, WHILE THE
SOCKET IS REMOVED FROM SHIPPING PLATE OR PCB.
WHILE SOCKET IS STILL MOUNTED TO PCB, USE SCRATCH BRUSH AND/OR EXACTO KNIFE
TO REMOVE COMPACTED DEBRIS FROM MICROSTRIP CONTACTS. (ALWAYS SCRUB OR
SCRAPE CONTACTS IN PARARELL DIRECTION WITH CONTACTS.)
REMOVE SOCKET FROM PCB AND BLOW OFF ANY LOOSE DEBRIS WITH FILTERED AIR.
POUR RDZ-1699 DE-OX II INTO CONTAINER. MAKE SURE THERE IS ENOUGH TO COVER THE
CONTACTS WHEN SOCKET IS IMMERSED.
HEAT THE RDZ-1699 DE-OX II ON THE HOT PLATE TO +120°F. (NOT CELSIUS!)
PLACE SOCKET, OR CONTACT BLOCK, INTO CONTAINER AND SOAK FOR 5-6 MINUTES.
(NOTE: DO NOT USE ULTRASONIC CLEANER.)
REMOVE SOCKET AND RINSE WITH DISTILLED WATER.
BLOW DRY SOCKET WITH FILTERED AIR AND BAKE SOCKET FOR 10 MINUTES AT 85°C.
WHILE SOCKET IS DRYING, CLEAN PCB TRACES WITH SCRATCH BRUSH AND ALCOHOL.
BLOW DRY WITH FILTERED AIR.
MOUNT SOCKET BACK ONTO THE PCB AND CONTINUE TESTING.
REPEAT ABOVE PROCEDURE UNTIL CONTACTS CAN NO LONGER BE USED FOR TEST.