BUYERS GUIDE Index What is Mallory FIRESTORM™ .............................3 Features & Benefits...............................................4 FI s i t a Wh ORM™? REST on t u o Find ext page. the n Dare to Compare Charts.................................. 5-11 How to Buy.................................................... 12-14 New Product Data Sheets..........................Appendix www.malloryfirestorm.com I 2 Introducing, the FIRESTORM™ Ignition line from Mallory Ignition Mallory Ignition is hitting the streets with its latest innovation, FIRESTORM™! It’s so big that we’ve created this quick reference guide to help you! Welcome to the Innovative Future of Mallory Ignition! www.malloryfirestorm.com I 3 Features & Benefits: Street Module: • Select 4-6 or 8 cylinders • Pick From 7 Ignition Type Inputs • Shift Light/Cam Tach Output • Malfunction Indicator Lamp • MAX RPM Rev Limiting • 2 Step RPM Rev Limit • 3 Step Rev Limit • Tachometer Output • Manifold Absolute Pressure (Monitor and Function) • MAP input for Boost Timing adjustments (1-5 BAR, w/Custom settings available) • Idle-spark control (Idle stability enhancement) • Launch Mode • Diagnostics – Built in Trouble Codes ligent l e t n I grated, System e t n I The rol t n o C on, i n s i o i c t i e r n Ig er, p w o p g d by e n i h r e c v t i l a de l unm o r eet t r t n s o c r o and tor f i t e p m ns. any co e applicatio and rac PRO – includes Street Features above, PLUS: • Fan Primary Control • Fan Secondary Control • Fuel Pump – Adjustable Prime (ts) and Safety Shutoff • Wide Band O2 Monitor • Vehicle Speed Input – (2 Input Types) •E ngine Coolant Temperature (Monitor and Function) • Air Temperature (Monitor and Function) • Throttle Position (Monitor and Function) • Auxiliary Output (Via MAP, TPS, RPM Switch) • 3D Individual Cylinder Timing Control • 3D Timing Maps • Dashboard (Easy Lookups) • Timing Retard Function (1 stage) • Coil On Plug capable (Smart or Conventional) • RPM based, adjustable Dwell control • Crank and Cam signal versatility •C ustom View Modes (view tables in KPa, HG, BAR) • Internal Data Logger -2M RAM w/graphical display www.malloryfirestorm.com I 4 Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. SINGLE CHANNEL MALLORY 69000S 6 Series CD Perf-Street MSD - 6520 MSD - 6530 DIG6 6AL-2 Plus Ignition Programmable MALLORY 69000SR MSD - 7520 MSD - 7531 6 Series CD Pro Series DIG7 Plus Ignition DIG7 Plus Ignition Specifications Spark Energy Primary Voltage Secondary Voltage RPM Range Operating Voltage Current Draw (AMP PER RPM) MAX HP Cylinder Select 4-6-8 150mJ 135 MJ 135 MJ 150mJ 190MJ 190MJ 550V 535 Volts 535 Volts 550V 535 Volts 535 Volts 55,000 Volts 45,000 45,000 55,000 Volts 40,000 40,000 12.5k 12k 12k 12.5k 12K 12K 12 to 18 Volts 12 to 18 Volts 9 to 18 Volts .7 AMP Per 1000 .7 AMP Per 1000 .7 AMP Per 1000 9 to 18 Volts 12 to 18 Volts 12 to 18 Volts .7 Per 1000 RPM 1.1 AMP Per 1000 1.1 AMP Per 1000 1000 N/A N/A 1000 N/A N/A 4 4 4 4 4 4 4 4 4 4 4 4 4 NO NO NO NO NO NO NO NO NO NO NO NO 4 4 4 4 4 4 4 4 NO NO NO NO NO NO 4 4 4 4 4 4 4 4 4 NO NO NO 4 4 Trigger Inputs GM HEI GM LT1 FORD TFI Hall Effect Inductive Pickup 4X Low Res Inductive Pickup 36-1 HI RES Points (Square Wave 12V) Data Logging (PRO) Launch Control 4 NO 4 4 4 4 NO NO NO NO NO NO NO Activation Switch By RPM By Time By PSI By TPS (PRO) Shift Light/Cam Tach 4 NO NO Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Malfunction Light Tachometer 4 4 NO NO 4 4 3D NO 2D Curve 4 4 4 4 4 4 4 4 4 4 NO NO NO 4 4 4 NO NO NO 4 NO NO NO NO NO NO NO NO 4 4 Timing & Retards 16x16 Timig Table (W/MAP) Individual Cyl Control (PRO) Individual Gear Timing Map 3D NO 2D Curve 3D NO 2D Curve NO NO 2D Curve 16x16 Step Retard (W/MAP) 3D Curve Single Step 2D Curve 3D Curve 3 STEP 2D Curve Boost Retard 16x16 (W/MAP) 4 NO 2D Curve 3D NO 2D Curve continued on pg 6 www.malloryFIRESTORM™.com I 5 Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. SINGLE CHANNEL MALLORY 69000S MSD - 6520 MSD - 6530 6 Series CD Perf-Street DIG6 Plus Ignition 6AL-2 Programmable 4 4 4 4 4 4 4 4 MALLORY 69000SR MSD - 7520 MSD - 7531 6 Series CD Pro Series DIG7 Plus Ignition DIG7 Plus Ignition 4 4 4 4 4 4 4 4 4 4 4 NO NO NO NO NO NO Up to 5 BAR NO Up to 3 BAR 4 4 NO NO NO NO NO NO 4 NO 4 4 Rev Limiters Main Rev Limit 2 Step 3 Step NO NO Sensors (optional) Inlet Air Temp (PRO) Coolant Temp (PRO) Throttle Position (PRO) 1,2,3,4 & 5 BAR MAP Up to 5 BAR NO Up to 3 BAR Wide Band O2 (PRO) VSS (PRO) Traction Control Real Time Tuning VIA Lap Top 4 MALLORY FORD 69150C CD Ford MOD COP NO MSD - 6011 Ford MOD Ign. Controller 4 MALLORY 69150C CD Multi Coil Street MSD - 62152 DIS-4 Plus CD COP MOD MALLORY 69150R MSD - 62153 DIS-4 Plus H/O CD COP MOD CD Multi Coil PRO Specifications Spark Energy Primary Voltage Secondary Voltage RPM Range Operating Voltage Current Draw (AMP PER RPM) MAX HP Cylinder Select 4-6-8 150mJ Inductive 150mJ 110 150mJ 170 550V OEM TYPE NO CD 550V 470 550V 470 55,000 Volts OEM TYPE NO CD 55,000 Volts 40,000 55,000 Volts 43,000 12.5k OEM TYPE NO CD 12.5k 14K 12.5k 14K 9 to 18 Volts OEM TYPE NO CD 9 to 18 Volts 10-18 Volts 9 to 18 Volts 10-18 Volts .7 Per 1000 RPM OEM TYPE NO CD .7 Per 1000 RPM 10 AMPS @ 10000 .7 Per 1000 RPM 10 AMPS @ 10000 1000 N/A 1000 N/A 1000 N/A 4 NO 4 6-8 CYL (2 Required for V8) 4 6-8 CYL (2 Required for V8) 4 4 4 Requires ECM to Trigger the Coils 4 Requires ECM to Trigger the Coils 4 4 NO 4 4 4 NO Trigger Inputs 36-1 - Cam Sync Data Logging (PRO) Launch Control 4 4 4 NO 4 4 4 NO 4 4 4 NO NO Activation Switch By RPM By Time By PSI NO NO NO NO NO NO continued on pg 7 www.malloryfirestorm.com I 6 Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. MALLORY FORD 69150C MSD - 6011 CD Ford MOD Ford MOD Ign. Controller COP MALLORY 69150C MSD - 62152 CD Multi Coil Street DIS-4 Plus CD COP MOD By TPS (PRO) Shift Light/Cam Tach 4 3D NO 4 4 2D Curve 3D NO 3D NO 3D NO NO 4 Fan 2 (PRO) Tachometer CD Multi Coil PRO MSD - 62153 DIS-4 Plus H/O CD COP MOD 4 4 NO Fan 1 (PRO) 4 4 69150R 4 4 4 4 4 4 4 Fuel Pump (PRO) Malfunction Light MALLORY NO NO NO NO NO NO NO 4 Timing & Retards 16x16 Timig Table (W/MAP) Individual Cyl Control (PRO) 16x16 Step Retard (W/MAP) 3D Single Step 1D 3D Single Step 1D 3D Single Step 1D Boost Retard 16x16 (W/MAP) 3D NO 3D NO 3D NO 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 NO Rev Limiters Main Rev Limit 2 Step 3 Step NO NO Sensors (optional) Inlet Air Temp Coolant Temp Throttle Position 1,2,3,4 & 5 BAR MAP Up to 5 BAR Up to 3 BAR Up to 5 BAR NO Wide Band O2 (PRO Only) vss Real Time Tuning VIA Laptop PC 4 4 4 NO NO NO NO NO NO NO Want e ven more? Turn t he page ! www.malloryfirestorm.com I 7 Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. MALLORY LS 69050S MALLORY 69100S MALLORY 69050R MALLORY 69100R MSD - 6010 MSD - 6011 LS1-LS6 LS2-LS7-LS9 LS2-LS7-LS9 PRO LS1-LS6 PRO LS2-LS7-LS9 LS1-LS7-LS9 Igntion Module Igntion Module Igntion Module Igntion Module Igntion Module Igntion Module Specifications Spark Energy OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD Primary Voltage OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD Secondary Voltage OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD RPM Range OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD Operating Voltage OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD Current Draw (AMP PER RPM) OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD OEM TYPE NO CD 700 700 700 700 N/A N/A MAX HP (Limited by Smart Coil) Trigger Inputs 24X - Cam Sync 4 58X - Cam Sync Cylinder Select 4-6-8 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 NO NO 4 4 3D 3D 3D 3D 2D Curve 2D Curve 3D 3D Data Logging (PRO) Launch Control 4 4 NO NO 4 4 NO NO NO NO NO NO NO NO Activation Switch By RPM By Time By PSI By TPS (PRO) Shift Light/Cam Tach Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Malfunction Light Tachometer Timing & Retards 16x16 Timig Table (W/MAP) Individual Cyl Control (PRO) 16x16 Step Retard (W/MAP) 3D 3D 3D 3D Single Step 2D Curve Single Step 2D Curve Boost Retard 16x16 (W/MAP) 3D 3D 3D 3D NO NO 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Rev Limiters Main Rev Limit 2 Step 3 Step continued on pg 11 www.malloryfirestorm.com I 8 Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. MALLORY LS 69050S MALLORY 69100S MALLORY 69050R MALLORY 69100R MSD - 6010 MSD - 6011 LS1-LS6 LS2-LS7-LS9 LS1-LS7-LS9 LS2-LS7-LS9 PRO LS1-LS6 PRO LS2-LS7-LS9 Igntion Module Igntion Module Igntion Module Igntion Module Igntion Module Igntion Module Sensors (optional) Inlet Air Temp 4 4 4 4 4 4 Up to 5 BAR Up to 5 BAR Up to 5 BAR Up to 3 BAR Up to 1 BAR 4 4 4 4 4 4 4 4 4 Coolant Temp Throttle Position 1,2,3,4 & 5 BAR MAP Up to 5 BAR Wide Band O2 (PRO Only) vss Real Time Tuning VIA Lap Top HEMI 4 MALLORY 69200S - CD MULTI MALLORY 69200R - CD MULTI 150mJ 150mJ Inductive 550V 550V OEM TYPE NO CD 55,000 Volts 55,000 Volts OEM TYPE NO CD 12.5k 12.5k OEM TYPE NO CD COIL HEMI COP STREET COIL HEMI COP PRO MSD - 6013 HEMI Ignition Control Specifications Spark Energy Primary Voltage Secondary Voltage RPM Range Operating Voltage Current Draw (AMP PER RPM) MAX HP Cylinder Select 4-6-8 9 to 18 Volts 9 to 18 Volts OEM TYPE NO CD .7 Per 1000 RPM .7 Per 1000 RPM OEM TYPE NO CD 1000 1000 N/A 4 4 NO 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 NO Trigger Inputs HEMI - Cam/Crank Sync Data Logging (PRO) Launch Control 4 4 Activation Switch By RPM By Time By PSI 4 4 4 By TPS (PRO) Shift Light/Cam Tach 4 Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Malfunction Light Tachometer 4 4 NO NO NO NO 4 www.malloryfirestorm.com I 9 Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. MALLORY 69200S - CD MULTI MALLORY 69200R - CD MULTI 3D 3D 16x16 Step Retard (W/MAP) 3D 3D Single Step 1D Boost Retard 16x16 (W/MAP) 3D 3D 2D Curve 4 4 4 4 4 4 4 4 HEMI COIL HEMI COP STREET COIL HEMI COP PRO MSD - 6013 HEMI Ignition Control Timing & Retards 16x16 Timig Table (W/MAP) Individual Cyl Control (PRO) 2D Curve 3D Rev Limiters Main Rev Limit 2 Step 3 Step NO Sensors (optional) Inlet Air Temp 4 4 4 Coolant Temp Throttle Position 1,2,3,4 & 5 BAR MAP Up to 5 BAR Up to 5 BAR Up to 3 Bar 30 PSI 4 4 4 4 4 Wide Band O2 (PRO Only) vss Real Time Tuning VIA Lap Top UNIVERSAL COP/EDIST MALLORY 69000M MALLORY 69000MR MSD - 62152 CD MULT COIL STREET CD MULT COIL PRO DIS-4 Plus CD COP MOD 150mJ 150mJ 110 550V 550V 470 55,000 Volts 55,000 Volts 40,000 12.5k 12.5k 14K 9 to 18 Volts 9 to 18 Volts 10-18 Volts .7 Per 1000 RPM .7 Per 1000 RPM 10 AMPS @ 10000 1000 1000 N/A 4 4 6-8 CYL (2 Required for V8) 36-1 - Cam Sync 4 4 Not a Stand Alone Requires ECM to Trigger the Coils Inductive Pickup 4X Low Res 4 4 4 4 Specifications Spark Energy Primary Voltage Secondary Voltage RPM Range Operating Voltage Current Draw (AMP PER RPM) MAX HP Cylinder Select 4-6-8 Trigger Inputs Data Logging (PRO) Launch Control 4 NO continued on pg 11 www.malloryfirestorm.com I 10 Dare to COMPARE: Mallory versus MSD on features and benefits. Comparing similar products. UNIVERSAL COP/EDIST MALLORY 69000M MALLORY 69000MR MSD - 62152 CD MULT COIL STREET CD MULT COIL PRO DIS-4 Plus CD COP MOD 4 4 4 NO 4 4 4 4 4 4 4 4 4 4 4 4 4 16x16 Timig Table (W/MAP) 3D 3D NO Individual Cyl Control (PRO) 3D 3D NO 16x16 Step Retard (W/MAP) 3D 3D Single Step 1D Boost Retard 16x16 (W/MAP) 3D 3D NO 4 4 4 4 4 4 4 4 Outputs Activation Switch By RPM By Time By PSI By TPS (PRO) Shift Light/Cam Tach 4 Fuel Pump (PRO) Fan 1 (PRO) Fan 2 (PRO) Malfunction Light Tachometer NO NO NO NO Timing & Retards Rev Limiters Main Rev Limit 2 Step 3 Step NO Sensors (optional) Inlet Air Temp 4 4 4 Coolant Temp Throttle Position 1,2,3,4 & 5 BAR MAP Up to 5 BAR Up to 5 BAR NO 4 4 4 4 NO Wide Band O2 (PRO Only) vss Real Time Tuning VIA Lap Top www.malloryfirestorm.com I 11 You need it, now here’s how to help a consumer buy it... Follow these easy steps to build your FIRESTORM™ Ignition System! Step 1: Select a FIRESTORM™ Ignition Box CHECK ONE: r 69000S - Ign, FIRESTORM™ CD Single Channel Street r 69000M - Ign, FIRESTORM™ CD Multi Channel Street r 69000SR - Ign, FIRESTORM™ CD Single Channel Pro r 69000MR - Ign, FIRESTORM™ CD Multi Channel Pro r 69050S - Ign, FIRESTORM™ LS1-LS6 24X Street r 69100S - Ign, FIRESTORM™ LS2-3-7-9 58Xstreet r 69050R - Ign, FIRESTORM™ LS1-LS6 24X Pro r 69100R - Ign, FIRESTORM™ LS2-3-7-9 58X Pro r 69150E - Ign, FIRESTORM™ CD Ford Edis Street r 69150C - Ign, FIRESTORM™ CD Ford C.O.P. Street r 69150R - Ign, FIRESTORM™ CD Ford C.O.P. Pro r 69200S - Ign, FIRESTORM™ CD Hemi Street r 69200R - Ign, FIRESTORM™ CD Hemi Pro Step 2: Select a Coil or Coil Pack CHECK ONE: r 140050 - Coil, FIRESTORM™, Bottom Tower r 140051 - Coil, FIRESTORM™, Single Tower r 140051-8 - Coil, FIRESTORM™, Single Tower, 8 Pack r 140052 - Coil, FIRESTORM™, Dual Tower (Waste Spark) r 140053 - Coil, FIRESTORM™, LS Bottom Tower r 140054 - Coil, FIRESTORM™, LS Universal Tower Step 3: Select a Distributor or 36-1 Crank Trigger CHECK ONE: Dual Sync Distributors (Required For Individual Cylinder Control Operations) r 77100M - Dist, Dual Sync Chev Sm Cap r 77100TM - Dist, Dual Sync Chevy Tall Deck Sm Cap r 77190M - Dist, Dual Sync Chevy Lg Cap r 77190TM - Dist, Dual Sync Chevy Taqll Deck Lg Cap r 77200M - Dist, Dual Sync Ford FE Sm Cap r 77201M - Dist, Dual Sync Ford 302 Sm Cap r 77204M - Dist, Dual Sync Ford 460 Sm Cap r 77207M - Dist, Dual Sync Ford 351W Sm Cap r 77242M - Dist, Dual Sync Jeep 4.0L W Sm Cap r 77291M - Dist, Dual Sync Ford 302 Lg Cap r 77297M - Dist, Dual Sync Ford 351W Lg Cap www.malloryfirestorm.com I 12 Step 3: Select a Distributor or 36-1 Crank Trigger CHECK ONE: r 77401M - Dist, Dual Sync Olds Sm Cap r 77441M - Dist, Dual Sync Buick 455 Sm Cap r 77548M - Dist, Dual Sync Cad Sm Cap r 77580M - Dist, Dual Sync Pont Sm Cap r 77601M - Dist, Dual Sync AMC Sm Cap r 77701M - Dist, Dual Sync Chry B Sm Cap (383 - 400) r 77801M - Dist, Dual Sync Chry RB Sm Cap (426 -440) r 77901M - Dist, Dual Sync Chry LA Sm Cap (318-340-360) Mallory Dual Sync Sensor (For Use In Conversions To Coil On Plug) r 77100D - FIRESTORM™ Chevy CAM/CRANK Sensor r 77100TB - FIRESTORM™ Chevy Tall Deck CAM/CRANK Sensor r 77201D - FIRESTORM™ Ford 302 CAM/CRANK Sensor r 77207D - FIRESTORM™ Ford 351W CAM/CRANK Sensor r 64667D - FIRESTORM™ Sensor Cap Assy (Replacement Sensor Assy) 36-1 Hi Resolution Crank Trigger Kits & Acc. r 76301 - Kit, Crk Trigger, Chev Bb r 76302 - Kit, Crk Trigger, Chev Sb 8” r 76303 - Kit, Crk Trigger, Chev Sb 6” r 76304 - Kit, Crk Trigger, Ford 6” r 76305 - Kit, Crk Trigger, Univ 8” r 76400 - Sensor, Crank, 3/4”-16 Magnetic (Replacement Sensor) a Ignition Adapter Step 4: Select Harness CHECK ONE: r 77101M - Mallory Dual Sync/Hall Effect Ignition Adapter Harness r 77170M - Mallory L98 Ignition Adapter Harness r 77642 - Mallory Ignition Hharness, Dual Sync Sensor Chevy r 77643 - Mallory Ignition Harness, Dual Sync Sensor Ford/Big Block Mopar r 77644 - Harness, Ford Early Crank/Cam r 77645 - Harness, Ford Late Crank/Cam r 77647 - Harness, Hemi Crank/Cam r 77652M - LT1 Ignition Adapter Harness 92-94 r 77653M - LT1-LT4 Ignition Adapter Harness 95-97 r 77660M - Ford TFI Ignition Adapter Harness r 77688M - IPU Ignition Adapter Harness r 78654M - LS1-LS6 Ignition Harness (24X) r 78655M - LS2 Thru LS9 Ignition Harness 60-2 (58X) Step 5: Select a Sensor or Sensor Kit CHECK ONE: r 74782M - Sensor Kit with 1 Bar Map (Naturally Aspirated Engines) r 74783M - Sensor Kit with 2 Bar Map (Up to 15 PSI of Boost) r 74784M - Sensor Kit with 3 Bar Map (UP to 30 PSI of Boost) r 74785M - Sensor Kit with 4 Bar Map (UP to 41 PSI of Boost) r 74787M - Sensor Kit with 5 Bar Map (UP to 60 PSI of Boost) r 74764M - 1 Bar Map Sensor (Naturally Aspirated) r 74776M - 2 Bar Map Sensor (Up to 15 PSI of Boost) r 74777M - 3 Bar Map Sensor (UP to 30 PSI of Boost) r 74786M - 4 Bar Map Sensor (UP to 41 PSI of Boost) r 74788M - 5 Bar Map Sensor (UP to 60 PSI of Boost) www.malloryfirestorm.com I 13 Step 6: Select Spark Plug Wires CHECK ONE: Mallory Spiral Core Sidewinder Plug Wires r 937 - Wire Kit, Universal Red 8MM Pro Sidewinder 90 Deg r 938 - Wire Kit, Universal Red 8MM Pro Sidewinder Straight r 947 - Wire Kit, Universal Red 8MM Pro Sidewinder 45 Deg ACCEL Extreme 9000 Ceramic Universal Spark Plug Wires r 9000C - 180 Deg Straight Boots W/Male-Female Tower Caps r 9001C - 90 Deg 5/8 Hex Plug Boots W/Male-Female Tower Caps r 9002C - 115 Deg Ford Style Boots W/Male-Female Tower Caps Step 7: Select an Accessory CHECK ONE: r 77171M - Harness, Univesral Accessories (Radiator Fan - Fuel Pump Control Kit - Aux Out) r 77177M - Malfunc Ind Lamp Harness r 77635 - Harness, 2 Wire, Coil FIRESTORM™ r 77636 - 8 Pin Acc, Harness, FIRESTORM™ r 77637 - 10 Pin Acc, Harness, FIRESTORM™ r 77638 - Main Harness LS r 77639 - Main Harness Multi Channel r 77640 - Intrconnect, Coil, LS Even r 77641 - Intrconnect, Coil, LS Odd r 77646 - Harness, Ford Cop Coil r 77648 - Harness, Hemi Coil Odd r 77649 - Harness, Hemi Coil Even Step 8: Select Wide Band 02 Kits CHECK ONE: r 77062 - Wide Band Kit Single Channel (Comes With 77061 Sensor - Limited To 10 PSI Boost) r 77062N - Wide Band Kit Single Channel (Requires The Purchase Of 77065 NTK O2 Sensor) r 77062S - Single U3 Wideband O2 Kit W/ Gauge r 77063 - Wide Band Dual Channel (Comes With 77061 Sensors - Limited To 10 PSI Boost) r 77063S - WB O2 Gauge & Harness Kit r 77061 - Bosch Wide Band O2 Sensor Replacement (Limited To 10 PSI Of Boost) r 77065 - NTK Wide Band O2 Sensor (Great For Turbo Or Supercharged Applications Exceeding 10 PSI Boost) Bring to any Mallory Ignition Dealer to get yours NOW! Need to find a dealer? Visit www.malloryfirestorm.com www.malloryfirestorm.com I 14