Frame grabber cables for flat panel sensor

Frame grabber cables for flat panel sensor
A8406 series
Various types of cables for frame grabber
A flat panel sensor adopting parallel video output requires a frame grabber cable for transmitting the digital video data to a
frame grabber card installed in PC.
Frame grabber cables A8406 series are cables that connect the flat panel sensor to a frame grabber.
The A8406 series has high performance and high reliability as digital video cables, and they are also designed for EMC
conformity. The wires are covered by double shielding and they have ferrite cores.
Selection guide
Frame grabber
General-purpose
IMAQ PCI-1424*2
Cable type no.
A8406-51
A8406-56
A8406-57
A8406-58
A8406-52
A8406-53
A8406-54
A8406-55
Cable length
5m
7m
10 m
12 m
5m
7m
10 m
12 m
Cable end
open
10140-6000EL*1
PCS-XE100MA+*3
*1: Made by 3M Co. Ltd.
*2: Made by NI (National Instrument Corporation)
*3: Made by Honda Tsushin Kogyo Co. Ltd.
Refer to the datasheet for the flat panel sensor and choose a suitable cable for it. For compatibility with frame grabber boards, consult the
frame grabber board manufacturers.
www.hamamatsu.com
1
Frame grabber cables for flat panel sensor
A8406 series
Cable for general frame grabber A8406-51/-56/-57/-58
The A8406-51/-56/-57/-58 are cables that connect the flat panel sensor to a general frame grabber. One end of this cable has a 40pin plug mating with the flat panel sensor digital output receptacle, but the other end is left open. Connect the open end to a plug that
mates with the frame grabber to be used.
Cable color coding and specifications
Pin no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Signal
Data1+ (LSB)
Data2+
Data3+
Data4+
Data5+
Data6+
Data7+
Data8+
Data9+
Data10+
Data11+
Data12+*4
Data13+*5
Data14+*6
Reserved*7
Reserved*7
ExtTrgGrb (TTL)
Vsync+
Hsync+
Pclk+
Cable color
Blue
Green
Gray
Black
Pink
White
Orange
Brown
Red
Yellow
Purple
Blue
Brown
Red
Green
Gray
Black
Pink
White
Orange
Marking color
White (1)
White (1)
White (1)
Black (1)
White (1)
Red (2)
Black (1)
Black (1)
White (2)
White (2)
White (2)
Black (2)
Blue (2)
Black (1)
Pin no.
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Signal
Data1- (LSB)
Data2Data3Data4Data5Data6Data7Data8Data9Data10Data11Data12-*4
Data13-*5
Data14-*6
GND
GND
IntExt (TTL)
VsyncHsyncPclk-
Cable color
Orange
Brown
Red
Yellow
Purple
Blue
Green
Gray
Black
Pink
White
Orange
Gray
Yellow
Brown
Red
Yellow
Purple
Blue
Green
Marking color
Red (1)
White (1)
White (1)
White (1)
Black (1)
Blue (1)
White (2)
Black (1)
Red (1)
White (2)
White (2)
Black (2)
White (2)
Black (1)
Black (1)
Note: Numbers in parentheses of “Marking color” item show marking number.
*4: MSB for 12-bit
*5: MSB for 13-bit
*6: MSB for 14-bit
*7: The signals connected to these pins depend on each devices. Refer to the datasheet for the flat panel sensor.
Dimensional outline (unit: mm, tolerance unless otherwise noted: ±1)
10140-6000EL
Ferrite core: SFC-8
11.5
40
1
21
8.0
42.4
20
40-pin cable
Ferrite core
SFC-8
Cable type no.
A
A8406-51
A8406-56
A8406-57
A8406-58
5000 ± 140
7000 ± 140
10000 ± 200
12000 ± 200
32.0
20
A
22
32
10340-A200-00,
10340-C200-00
KACCA0174EC
2
Frame grabber cables for flat panel sensor
A8406 series
Cable for IMAQ PCI-1424 frame grabber A8406-52/-53/-54/-55
The A8406-52/-53/-54/-55 cable are designed to connect the flat panel sensor to the National Instrument IMAQ PCI-1424 digital frame
grabber board. Both ends of this cable have connectors. One end is a 40-pin plug mating with the flat panel sensor digital output receptacle, while the other end is a 100-pin plug for the IMAQ PCI-1424.
Pin connection for A8406-52
10140-6000EL
Pin no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Signal
Data1+ (LSB)
Data2+
Data3+
Data4+
Data5+
Data6+
Data7+
Data8+
Data9+
Data10+
Data11+
Data12+*8
Data13+*9
Data14+*10
Reserved*11
Reserved*11
ExtTrgGrb (TTL)
Vsync+
Hsync+
Pclk+
PCS-XE100MA+
Pin no.
1
3
5
7
9
11
13
15
17
19
21
23
25
27
33
35
37
41
43
49
10140-6000EL
Pin no.
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Signal
Data1- (LSB)
Data2Data3Data4Data5Data6Data7Data8Data9Data10Data11Data12-*8
Data13-*9
Data14-*10
GND
GND
IntExt (TTL)
VsyncHsyncPclk-
PCS-XE100MA+
Pin no.
2
4
6
8
10
12
14
16
18
20
22
24
26
28
99
100
39
42
44
50
*8: MSB for 12-bit
*9: MSB for 13-bit
*10: MSB for 14-bit
*11: The signals connected to these pins depend on each devices. Refer to the datasheet for the flat panel sensor.
Note: The two types of output are available with flat panel sensors: RS-422 and LVDS. Select a digital frame grabber that matches the
output type of the flat panel sensor.
Dimensional outline (unit: mm, tolerance unless otherwise noted: ±1)
51.0
Ferrite core: SFC-8
PCS-XE100MA+
10340-A200-00,
10340-C200-00
51
A
1
21
1
22
32
85.1
40
8.0
42.4
20
20
11.5
Ferrite core
SFC-8
40-pin cable
100
32.0
50
PCS-XEM100LU2
10140-6000EL
16.0
20
Ferrite core: SFC-8
22
32
Cable type no.
A
A8406-52
A8406-53
A8406-54
A8406-55
5000 ± 140
7000 ± 140
10000 ± 200
12000 ± 200
KACCA0175EB
3
Frame grabber cables for flat panel sensor
A8406 series
Information described in this material is current as of September, 2014.
Product specifications are subject to change without prior notice due to improvements or other reasons. This document has been carefully prepared and the
information contained is believed to be accurate. In rare cases, however, there may be inaccuracies such as text errors. Before using these products, always
contact us for the delivery specification sheet to check the latest specifications.
Type numbers of products listed in the delivery specification sheets or supplied as samples may have a suffix "(X)" which means preliminary specifications or
a suffix "(Z)" which means developmental specifications.
The product warranty is valid for one year after delivery and is limited to product repair or replacement for defects discovered and reported to us within that
one year period. However, even if within the warranty period we accept absolutely no liability for any loss caused by natural disasters or improper product
use.
Copying or reprinting the contents described in this material in whole or in part is prohibited without our prior permission.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Solid State Division
1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 8152-375-0, Fax: (49) 8152-265-8
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777
North Europe: Hamamatsu Photonics Norden AB: Torshamnsgatan 35 16440 Kista, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01
Italy: Hamamatsu Photonics Italia S.r.l.: Strada della Moia, 1 int. 6, 20020 Arese (Milano), Italy, Telephone: (39) 02-93581733, Fax: (39) 02-93581741
Cat. No. KACC1123E06 Sep. 2014 DN
4