CPC1964B AC Power Switch INTEGRATED CIRCUITS DIVISION Parameter AC Operating Voltage Load Current On-State Voltage Drop Blocking Voltage Rating 20 - 280 1.5 1.4 800 Units Vrms Arms VP (at IL = 1.5AP) VP Features • • • • • • • • • • • • Load Current up to 1.5Arms 800VP Blocking Voltage 5mA Sensitivity 5000Vrms Input to Output Isolation Off-State dV/dt: 1000V/s Minimum 12.5mm External Creepage Distance with Appropriate Layout Zero-Cross Switching DC Control, AC Output Optically Isolated TTL and CMOS Compatible Low EMI and RFI Generation High Noise Immunity Description CPC1964B is an AC Solid State Switch utilizing dual power SCR outputs. This device also includes zero-cross turn-on circuitry and is specified with a blocking voltage of 800VP . In addition, the tightly controlled zero-cross circuitry ensures low noise switching of AC loads by minimizing the generation of transients. The optically coupled input and output circuits provide 5000Vrms of isolation between the control and load circuits. As a result, the CPC1964B is well suited for industrial environments where electromagnetic interference would disrupt the operation of plant facility communication and control systems. Approvals • UL 508 Certified Component: File E69938 • CSA Industrial Control Switches Approval: Pending Ordering Information Applications • • • • • • • • • • • Programmable Control Process Control Power Control Panels Remote Switching Gas Pump Electronics Contactors Large Relays Solenoids Motors Heaters Meters Part # CPC1964B Description 8-Pin Power SOIC (25/Tube) Pin Configuration 8 AC Load 7 AC Load 5 ZC 1 N/C DS-CPC1964B-R03 6 www.ixysic.com 2 + LED 3 – LED 4 N/C 1 INTEGRATED CIRCUITS DIVISION CPC1964B Absolute Maximum Ratings @ 25ºC Parameter Blocking Voltage (VDRM) Reverse Input Voltage Input Control Current Peak (10ms) Input Power Dissipation 1 Total Power Dissipation 2 Isolation Voltage Input to Output ESD, Human Body Model i2t for Fusing (1/2 Sine Wave, 50Hz) Operational Temperature Storage Temperature 1 Derate linearly 1.33 mW / ºC 2 Derate linearly 20 mW / ºC Ratings 800 5 50 1 150 2400 5000 4 1.6 -40 to +85 -40 to +125 Units VP V mA A mW mW Vrms kV A2s °C °C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Electrical Characteristics @ 25ºC Parameters Output Characteristics Load Current, Continuous Maximum Surge Current Off State Leakage Current On-State Voltage Drop 1 Off-State dV/dt Switching Speeds Turn-on Turn-off Zero-Cross Turn-On Voltage 2 Holding Current Latching Current Operating Frequency Load Power Factor for Guaranteed Turn-On 3 Input Characteristics Input Control Current to Activate 4 Input Drop-out Voltage to Deactivate Input Voltage Drop Reverse Input Current Common Characteristics Input to Output Capacitance Conditions Symbol Min Typ Max Units VL=120-280Vrms t < 20ms IF=0mA, VL=VDRM IF=5mA, IL=1.5AP IF=0mA IL IP 0.1 1000 1.21 - 1.5 16 100 1.4 - Arms AP AP VP V/s ton toff IH IL 20 5 - 0.5 0.5 20 5 75 75 500 cycles cycles V V mA mA Hz f=60Hz PF 0.25 - - - f=60Hz, IL=1A Resistive IF=5mA VR=5V IF VF IR 0.8 0.9 - 1.2 - 5 1.4 10 mA V V A - CI/O - - 3 pF IF = 5 mA 1st half cycle Subsequent half cycle - ILEAK dV/dt 1 Tested at a peak value equivalent. 2 Zero Cross 1st half cycle @ <100Hz. 3 Snubber circuits may be required at low power factors. 4 For high-noise environments, or for high-frequency operation, use I > 10mA. F 2 www.ixysic.com R03 INTEGRATED CIRCUITS DIVISION CPC1964B PERFORMANCE DATA* (@25ºC Unless Otherwise Noted) Typical LED Forward Voltage Drop (N=50, IF=5mA) 35 35 20 15 10 25 20 15 10 10 5 0 0 0 1.25 1.26 1.27 1.28 1.29 LED Forward Voltage (V) 30 Typical IF for Switch Operation Resistive Load (N=50, IL=1.5A, VL=120VAC, 60Hz) 15 10 35 25 20 15 10 0 0.8 1.0 1.2 1.4 1.6 LED Forward Current (mA) 1.6 1.4 LED Forward Current (mA) 1.5 1.3 1.2 1.1 850 865 880 895 910 Blocking Voltage (VP) 2.8 2.7 2.6 2.5 2.4 2.3 2.2 80 100 -40 Typical IF for Switch Operation vs. Load Frequency (Resistive) (IL=4.91Arms, VP=67V, RL=10:) -20 0 20 40 60 Temperature (ºC) 80 8.0 7.5 7.0 100 200 300 400 Load Frequency (Hz) 500 2.55 2.50 -40 -20 0 20 40 60 Temperature (ºC) 80 100 80 100 Holding Current (RL=1.9:) 70 60 50 40 30 20 6.5 0 2.60 80 2.2 2.0 2.65 Holding current (mA) Zero-Cross (V) 2.4 2.70 First Zero-Cross Turn-On Voltage (IF=5mA, RL=120:) 8.5 2.6 2.75 100 3.0 2.8 2.80 2.45 2.1 20 40 60 Temperature (ºC) 925 Typical IF for Switch Operation Inductive Load (IL=500mA, 60Hz, 200mH) 2.85 LED Forward Current (mA) 2.9 IF=50mA IF=20mA IF=10mA IF=5mA 1.8 Typical IF for Switch Operation Resistive Load (IL=350mA, 60Hz) Typical LED Forward Voltage Drop vs. Temperature 3.2 8.0 5 0.6 0 5.5 6.0 6.5 7.0 7.5 Zero Cross Voltage (V) Typical Blocking Voltage Distribution (N=50) Device Count (N) Device Count (N) 20 0 -20 5.0 30 5 -40 4.5 1.200 1.205 1.210 1.215 1.220 1.225 1.230 Forward Voltage (VP) 1.30 25 LED Forward Voltage (V) 15 5 5 LED Forward Current (mA) 20 Device Count (N) Device Count (N) 25 First Zero-Cross Turn-On Voltage Distribution (N=50, IF=5mA) 25 30 30 Device Count (N) On-State Forward Voltage Drop (N=50, IF=5mA, IL=1.5A) -40 -20 0 20 40 60 Temperature (ºC) 80 100 -40 -20 0 20 40 60 Temperature (ºC) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. R03 www.ixysic.com 3 INTEGRATED CIRCUITS DIVISION CPC1964B PERFORMANCE DATA* (@25ºC Unless Otherwise Noted) Typical Load Current vs. Load Voltage (IF=5mA) On-State Voltage vs. Temperature IL=1.5A 1.15 1.10 IL=1A 1.05 1.00 IL=0.5A 0.95 -20 0 20 40 60 Temperature (ºC) 80 100 -0.5 0.0 0.5 1.0 Leakage Current (PA) 1000 950 900 0 20 40 60 Temperature (ºC) 1.00 0.75 0.50 -40 1.5 -20 80 100 20 40 60 Temperature (ºC) 80 100 Maximum Surge Current vs. Time VL=800V VL=300V 1 0.1 0.01 0.001 -40 0 20 10 -20 1.25 Typical Leakage Current vs. Temperature 1050 Blocking Voltage (VP) -1.0 1.50 Load Voltage (V) Typical Blocking Voltage vs. Temperature 850 -40 1.75 @ 85ºC @ 25ºC @ -40ºC Load Current (AP) -40 2.5 2.0 1.5 1.0 0.5 0.0 -0.5 -1.0 -1.5 -2.0 -2.5 -1.5 Load Current (Arms) 1.20 Load Current (A) On-State Voltage (VP) 1.25 Maximum Load Current vs. Temperature (IL=5mA) -20 0 20 40 60 Temperature (ºC) 80 100 15 10 5 0 100Ps 1ms 10ms 100ms 1s Time (ms) 10s 100s *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.ixysic.com R03 INTEGRATED CIRCUITS DIVISION CPC1964B Manufacturing Information Moisture Sensitivity All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper operation of our devices when handled according to the limitations and information in that standard as well as to any limitations set forth in the information or standards referenced below. Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced product performance, reduction of operable life, and/or reduction of overall reliability. This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033. Device Moisture Sensitivity Level (MSL) Rating CPC1964B MSL 1 ESD Sensitivity This product is ESD Sensitive, and should be handled according to the industry standard JESD-625. Reflow Profile This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020 must be observed. Device Maximum Temperature x Time CPC1964B 245ºC for 30 seconds Board Wash IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used. Cleaning methods that employ ultrasonic energy should not be used. R03 www.ixysic.com 5 INTEGRATED CIRCUITS DIVISION CPC1964B Mechanical Dimensions CPC1964B 21.082 ± 0.381 (0.830 ± 0.015) Pin 8 16.764 ± 0.381 (0.660 ± 0.015) 3.302 ± 0.051 (0.130 ± 0.002) 0.127 ± 0.076 (0.005 ± 0.003) 15.90 (0.626) 10.160 ± 0.254 (0.400 ± 0.010) 2.00 (0.079) 0.889 ± 0.127 (0.035 ± 0.005) Pin 1 0.762 ± 0.102 (0.030 ± 0.004) 5.080 ± 0.127 (0.200 ± 0.005) 7.620 ± 0.127 (0.300 ± 0.005) Recommended PCB Pattern 1.524 typ (0.060) 1.016 ± 0.127 (0.040 ± 0.005) 1.651 ± 0.102 (0.065 ± 0.004) 5.080 ± 0.127 (0.200 ± 0.005) 0.381 ± 0.025 (0.015 ± 0.001) Dimensions Unless Otherwise Noted mm (inches) Note: Pin-to-pin tolerances are non-cumulative. 5.080 (0.200) 7.622 (0.300) 5.080 (0.200) 0.95 (0.037) For additional information please visit our website at: www.ixysic.com IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice. 6 Specification: DS-CPC1964B-R03 ©Copyright 2013, IXYS Integrated Circuits Division All rights reserved. Printed in USA. 10/18/2013