Datasheet - Littelfuse

Surge Protection Module
LED Lighting Surge Protection Module > LSP05
LSP05 Module Series
RoHS
Description
The Littelfuse LSP05 thermally protected Surge Protective
Device is a self-protected device which is specially designed
to be used in outdoor and commercial LED lighting fixtures
for transient overvoltage protection. It is constructed with
Littelfuse thermally protected varistor technology. Its built-in
thermal disconnect function provides additional protection
to prevent catastrophic failure and fire hazard even under the
extreme circumstances of varistor end-of-life or sustaining
over voltage conditions. The LSP05 SPD facilitates customer’s product compliance to IEEE C62.41.2 Location Category
C Low and US Dept of Energy MSSLC Model Spec.
Agency Approvals
Agency
Features
Standard
Agency File Number
UL1449
E320116
Applications
• Outdoor and Commercial
LED Lighting
• Roadway lighting
• Traffic lighting
• Digital signage
•
•
•
•
•
Wash wall lighting
Parking garage/lot lighting
Flood lighting
Tunnel lighting
Street lighting
Additional Information
• Maximum Discharge
Current, 10kA, 8/20us
• Meets ANSI C136.2
Enhanced Level 10kV/5kA
and IEEE C62.41.2
Location Category
C Low Exposure
• Parallel connected
SPD device
• Thermally protected
Varistor technology
• IP66 Water-proof
and Dust-proof
• Indication wire lead
options for Parallel
connected modules
• UL1449 Type 4
Component Assembly
Recognition
• IEC61643-11 Class II/
EN61643-11 Type
2 Compliant1
• Compact form factor
(48x48x30mm) with
mounting tabs
• 240Vac and 277Vac
voltage ratings are CE
compliant and available
for Class I and Class
II installation based
on IEC luminaire
protection classes
Notes:
1. Self-declared compliance.
Datasheet
Resources
Samples
Absolute Maximum Ratings
• For ratings of individual members of a series, see Device Ratings and Specifications chart
LSP05 Series
Units
150 to 510
V
Continous:
Steady State Applied Voltage:
Max AC Voltage Range (VM(AC)RMS)
Transient:
Maximum Discharge Current 8/20μs Waveform (Imax)
10,000
A
Nominal Discharge Current 8/20µs Waveform (In)
5,000
A
Operating Ambient Temperature Range (TA)
-45 to +85
°C
Storage Temperature Range (TSTG)
-45 to +125
°C
Isolation Voltage Capability (When the thermal disconnect opens)
Insulation Resistance
600
V
>1,000
MΩ
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of
the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
2
© 2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 07/06/15
Surge Protection Module
LED Lighting Surge Protection Module > LSP05
LSP05 Series Device Ratings & Specifications
MCOV/Uc
(VAC)5
Maximum
Discharge
Current
(Imax)(A)2
LSP05120*
120
150
10,000
LSP05240*
240
275
10,000
LSP05277*
277
320
10,000
LSP05347*
347
420
10,000
LSP05480*
480
510
10,000
L-L:240
L-L:275
LSP05240LL*
LSP05480LL*
L-N/G:120
L-N/G:150
L-L:480
L-L:510
L-N/G:277
L-N/G:320
Nominal
Discharge
Current
(In)(A)1
MLV
(V)3
Up
(V)4
L-N:680
L-G:680
800
N-G:630
L-N:1100
5,000
L-G:1100
1200
N-G:1100
L-N:1270
5,000
L-G:1270
1400
N-G:1220
Typical Dimensions (mm)
L-N:1600
5,000
L-G:160056.0 ±0.51700
N-G:1580
L-N:1780
5,000
L-G:1780
1900
N-G:1730
Safety Compliance
IEC/EN 61643-116
UL1449
5,000
10,000
5,000
10,000
5,000
L-L:1100
X
X
X
X
X
X
X
L-L:1200
L-N/G:680
L-N/G:800
L-L:1780
L-L:1900
L-N/G:1270
L-N/G:1400
X
48.0±1.5
2x ø4.8±0.2
X
X
X
LV UltraMOV™ Series
Operating
Voltage
(VAC)
Part Number7
Notes:
1. Nominal Discharge Current (In)(A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20us current waveform.
2. Maximum Discharge Current (Imax)(A): The maximum discharge current is a measure of the100
SPDs
maximum capability;
current uses3 the
8/20us current
indication
wires
±20
100 ±20
48.0single
±1.5 impulse of discharge
all use the AWG22.
waveform.
3. MLV – UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20us nominal discharge current (In); an average
voltage value of 15 impulses
4. Up – IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20us nominal discharge current (In); a
rounding voltage value of maximum measurement.
30.0 ±1.0
2.3
±0.2
5. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that
could
be continuously applied to the SPD.
6. Part Numbers LSP05xxxPM Only.
7. * = - P or PM
6 ±2
64.0 ±1.5
6 ±2
Dimensions
Typical Dimensions (mm)
56.0 ±0.5
48.0±1.5
2x ø4.8±0.2
100 ±20
48.0 ±1.5
100 ±20
30.0 ±1.0
2.3 ±0.2
6 ±2
3 indication wires
all use the AWG22.
64.0 ±1.5
6 ±2
LSP05XXXXXP
LSP05XXXXXPM
Notes:
1. Black: Line; White: Neutral; Green: Ground
(P/N with suffix X3333/X3316: Brown: Line; Blue: Neutral; Green-Yellow stripe: Ground)
2. Black: R1; Red: R2; Blue: R3
3. Wire Gauge: AWG14 wire Line in, AWG22 Wire for indication; Wire Length: 100mm or
customized
© 2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 07/06/15
3
Surge Protection Module
LED Lighting Surge Protection Module > LSP05
Part Numbering System
Application/Installation Schematic
L
L
or
N/G
L
L
N
N
AC/DC
Power
Supply
G
Parallel Connection
With LED indicating SPD status
- ON (green): SPD is online
- OFF: SPD needs replacement
-
LED Module
R1
R2
R3
SPD
LSP 05 480LL P Xxxxx
+
NC
LED normally on
LSP05xxxPM
Device Family
Littelfuse Surge Protection Module
Nominal Discharge
Current (In)
Operating Voltage
Connection mode
LL: for L,L,N/G
Blank: L-N, L-G, N-G
R
P or PM
L
L
or
N/G
L
L
N
N
AC/DC
Power
Supply
G
(P: parallel connection; PM: parallel
connection and with monitor indication wire)
+
-
LED Module
R1
Parallel Connection
SPD
LED normally off
R2
R3
With LED indicating SPD status
LSP05xxxPM
- OFF: SPD is online
- ON (red): SPD needs replacement
Other non-standard option:
X3333: with GND wire connection, available for
240Vac and 277Vac rating with CE Marking for
Class I earthed installation
X3316: without GND wire connection option
R
Notes:
1. LED indicator and associated circuitry are not included in the module.
2. R1 must be capped off by wire nut when not connected (NC).
3. R1 and R2 are AC line voltage (hot); R3 is AC neutral voltage.
4. R2 voltage is cut off when SPD needs replacement.
5. R is current limiting resistor; it resistance/wattage is determined by AC line voltage
and desired current driving LED. Example: AC line voltage 240V, LED: 1.6mA, resistor:
150Kohm/0.5W.
L
L
N/G
or
L
L
N
N
AC/DC
Power
-
LED Module
G
Parallel Connection
SPD
L
L
N
N
Parallel Connection
(for Class II Unearthed)
AC/DC
Power
Supply
G
4
+
Supply
+
-
LED Module
SPD
~X3316
© 2015 Littelfuse, Inc.
Specifications are subject to change without notice.