IEC 1000-4-2 ESD Immunity and Transient Current

IEC 1000-4-2 ESD Immunity and Transient Current
Capability for the SP72X Series Protection Arrays
A pplication Note
J uly 1999
AN9612.2
Author: Wayne Austin
The SCR structures are designed for fast triggering at a
threshold of one +VBE diode threshold above V+ (positive
supply terminal) or a -VBE diode threshold below V(negative or ground). A clamp to V+ is activated at each
protection input if a transient pulse causes the input to be
increased to a voltage level greater than one VBE above V+.
A similar clamp to V- is activated if a negative pulse, one VBE
less than V-, is applied to an input.
Various standards for testing the ESD capability of
semiconductor products have been developed in recent
years. Each standard was generated with regard to a
specific need related to the electromagnetic compatibility of
the system environment. They include the Human Body
Model (HBM), Machine Model (MM) and the Charged Device
Model (CDM). Each such standard relates to the nature of
electrostatic discharge generated within a system
application and the potential for damage to the IC. For these
better known standards, the actual results for ESD tests on
the SP720 and SP721 are as follows:
1. Human Body Model using a modified version of the
MIL-STD-883, Method 3015.7; with V+ and V- grounded
and ESD discharge applied to each individual IN
pin - Passed all test levels from ±9kV to ±16kV (1kV steps).
2. Human Body Model using the MIL-STD-883, Method
3015.7 (with V- only grounded) and ESD discharge
applied to each individual IN pin - Passed all test levels
to ±6kV, failed ±7kV (1kV steps).
3. Machine Model using EIAJ IC121 (RD = 0Ω); discharge
applied to IN pins with all others grounded - Passed all
test levels to ±1kV, failed ±1.2kV; (200V steps).
4. Human Body Model using the IEC 1000-4-2 standard with
V+ and V- grounded and ESD discharge applied to each
individual IN pin - Passed test Level 2.
The SP723 capability surpasses those of the SP720 and
SP721 and meets the Level 4 requirements of the IEC
1000-4-2 HBM standard.
10-61
IEC 1000-4-2 ESD Standard
One of the more recent standards to be developed is the IEC
(International Electrotechnical Commission) 1000-4-2. The
IEC document relates to the HBM but encompasses a range
of normal environmental conditions. Testing for ESD
immunity is more broadly defined to include a device,
equipment or system. Both direct contact and air discharge
methods of testing are used with four discrete steps in the
severity level ranging up to 8kV and 15kV respectively. In its
simplest form, the Figure 1 test circuit provides for a means
of charging the 150pF capacitor, RC through the charge
switch and discharging ESD pulses through the 330Ω
resistor, RD and discharge switch to the Equipment or
Device Under Test (EUT, DUT) under test.
RC
CHARGE
SWITCH 50-100MΩ
±DC
HV
EC
RD DISCHARGE
SWITCH
330Ω
CD
150pF
EUT
OR
DUT
FIGURE 1. SIMPLIFIED IEC 1000-4-2 ESD TEST ENERGY
SOURCE
The test equipment for the IEC 1000-4-2 standard is
constructed to provide the equivalent of an actual human
body ESD discharge and has the waveform shown in
Figure 2.
CURRENT
The SP720, SP721, SP723, and SP724 are protection ICs
with an array of SCR/Diode bipolar structures for ESD and
over-voltage protection of sensitive input circuits. They have
2 protection SCR/Diode device structures per input. The
SP720 is supplied in 16 lead DIP and SOIC packages and
has a total of 14 available inputs that can be used to protect
up to 14 external signal or bus lines. The SP721 and SP723
are 8 pin devices with the same protection structures and
have the same package options. The SP723 has dual cell
structures for each input to achieve substantially improved
ESD and Transient Current capability. The SP724 is a four
section array in a 6-lead SOT-23. Its cell structure has been
redesigned for improved ESD immunity.
100%
IPEAK
90%
I AT 30ns
I AT 60ns
10%
30ns
60ns
TIME
tR = 0.7 TO 1ns
FIGURE 2. TYPICAL WAVEFORM OF THE OUTPUT
CURRENT OF THE HBM ESD GENERATOR AS
SPECIFIED IN THE IEC 1000-4-2 STANDARD
1-800-999-9445 or 1-847-824-1188 | Copyright
© Littelfuse, Inc. 1999
Application Note 9612
The IEC 1000-4-2 severity level of testing is defined by
stepping the DC High Voltage rather than changing the RC
discharge components. The severity levels are separately
defined for plus and minus polarity of direct contact discharge
(preferred) and air discharge as shown in Table 1. Other voltage
levels may be specified for the IEC 1000-4-2 test equipment
and conditions.
TABLE 1. IEC 1000-4-2 SEVERITY LEVELS
LEVEL
TEST VOLTAGE, kV
CONTACT DISCHARGE
TEST VOLTAGE, kV
AIR DISCHARGE
1
2
2
2
4
4
In Table 2C, all pins on six SP720 and four SP721 devices
were tested for ESD Air Discharge Capability and passed
without failures up to 16.5kV. This is better than the IEC
1000-4-2 standard to Level 4 severity requirements. The
SP723 was tested using the same conditions given for the
SP720 and SP721.
TABLE 2A. SP720 TESTS TO IEC 1000-4-2 STRESS LEVELS
USING DIRECT CONTACT
STRESS
LEVELS
3
6
8
4
8
15
As a subsystem component, the SP720, SP721 and SP723
may be used at the PC board or module interface for
protection. In a typical application, the ESD Protection
Arrays would be used to protect more sensitive circuits at the
line interface or input terminals to a board or module.
Normally, the circuit configuration of Figure 3 is the
recommended way to protect ESD sensitive inputs which
relates to the IEC 1000-4-2 definitions for equipment,
systems, subsystems and peripherals. To determine the
capability of ESD Protection Arrays to protect an active
circuit, the ESD Protection Arrays were tested as single
devices. Following the conditions of the IEC 1000-4-2
specification, both direct contact and air discharge ESD
tests were performed.
SYSTEM SUBCIRCUIT OR MODULE
VCC OR
V+ SUPPLY
V+
general, the SP720 and SP721 have the capability to
withstand Level 2 direct contact ESD discharge for the test
conditions defined in the IEC 1000-4-2 standard.
(+) DIRECT CONTACT
DISCHARGE VOLTAGE
LEVELS TO EACH PIN
(-) DIRECT CONTACT
DISCHARGE VOLTAGE
LEVELS TO EACH PIN
VCC = 0V, 5 Devices Tested
1, 2, 3
All Pass
All Pass
4
All Pass
2 Fail
VCC = 5.5V, 20 Devices Tested
1, 2
All Pass
All Pass
3
All Pass
8 Fail
4
All Pass
Remaining 12 Fail
VCC = 15V, 6 Devices Tested
1, 2
All Pass
All Pass
3
All Pass
3 Fail
4
All Pass
Remaining 3 Fail
TABLE 2B. SP721 TESTS TO IEC 1000-4-2 STRESS LEVELS
USING DIRECT CONTACT
STRESS
LEVELS
(+) DIRECT CONTACT
DISCHARGE VOLTAGE
LEVELS TO EACH PIN
(-) DIRECT CONTACT
DISCHARGE VOLTAGE
LEVELS TO EACH PIN
VCC = 5.5V, 20 Devices Tested
SIGNAL
INPUT
ACTIVE CIRCUIT
SP720
V-
GND OR
V- SUPPLY
1 OF 14 CELLS
FIGURE 3. ONE PROTECTION CELL OF THE SP720 SHOWN
AS PROTECTION INTERFACE ON A CIRCUIT
IEC 1000-4-2 ESD Test Evaluation
ESD Direct Contact and Air Discharge Capability
For V- = Ground, V+ = VCC (varied) and TA = 25oC, single
pulse ESD testing was done at each pin of the SP720 and
SP721. The results are shown in Tables 2A and 2B. In
10-62
1, 2
All Pass
All Pass
3
All Pass
8 Fail
4
All Pass
Remaining 12 Fail
TABLE 2C. SP720 AND SP721 TESTS TO IEC 1000-4-2
STRESS LEVELS USING AIR DISCHARGE
STRESS
LEVELS
(+) AIR DISCHARGE
VOLTAGE LEVELS
TO EACH PIN
(-) AIR DISCHARGE
VOLTAGE LEVELS
TO EACH PIN
VCC = 15V, 6 SP720, 4 SP721 Devices Tested
1
All Pass
All Pass
2
All Pass
All Pass
3
All Pass
All Pass
4
All Pass
All Pass
The SP723 was tested using the same conditions given for
the SP720 and SP721.
Application Note 9612
Table 2D shows the results for direct contact discharge and
Table 2E show the SP723 capability for air discharge. Where
each SP723 input has a dual input structure equal to the
SP720 and SP721 which pass Level 4 air discharge
conditions, the capability of the SP723 will exceed that by a
wide margin but testing was not done due to test equipment
limitations.
TABLE 2D. SP723 TESTS TO IEC 1000-4-2 STRESS LEVELS
USING DIRECT DISCHARGE
STRESS
LEVELS
(+) DIRECT DISCHARGE (-) DIRECT DISCHARGE
VOLTAGE LEVELS
VOLTAGE LEVELS
TO EACH PIN
TO EACH PIN
VCC = 15V, 8 Devices Tested
1, 2, 3, 4
All Pass
All Pass
TABLE 2E. SP723 IEC 1000-4-2 STRESS LEVEL CAPABILITY
USING AIR DISCHARGE
STRESS
LEVELS
(+) AIR DISCHARGE
VOLTAGE LEVELS
TO EACH PIN
(-) AIR DISCHARGE
VOLTAGE LEVELS
TO EACH PIN
Results based on SP720, SP721 Data
1, 2, 3, 4
All Pass
All Pass
Measured Peak Current in Direct Discharge ESD
Testing
Verification for peak current calibration during testing for the
ESD direct contact discharge was done for ESD Tests in
Table 2. The measured peak currents occurs in 1ns and the
50% discharge occurs in 30ns as shown in Figure 2. The
verified results as shown below in Table 3. These test levels
conform to the IEC 1000-4-2 standard requirement for peak
current to be within ±10%.
Multiple Pin Input ESD Test Evaluation
While the SP723 would be a preferred choice to extend the
range of ESD protection, by using 2 or more IN input pins of
the SP720 or SP721 also increases the range of ESD
immunity. For example, by connecting adjacent SP720 pins
in parallel using the dual pin combinations 1+2, 3+4, 5+6,
7+9, 10+11, 12+13 and 14+15, the IEC 1000-4-2 voltage
capability is increased to better than ±9kV. (The ±9kV level is
an equipment limited maximum voltage.)
Peak Current Capability
While the primary purpose of the SP720, SP721 and SP723
are for ESD protection, there is an implied need for surge
current immunity in some circuit applications. As noted by
the high peak currents recorded during ESD testing (Table
3), it can be expected that peak transient current capability
rises sharply as the width of the current pulse narrows.
Destructive testing was done to fully evaluate device ability to
withstand a wide range of peak current pulses vs time. The
circuit used to generate current pulses is shown in Figure 4.
The test circuit of Figure 4 is shown with a positive pulse input
as it would apply to the SP720. For a negative pulse input, the
(-) current pulse input goes to an SP720 ‘IN’ input pin and the
(+) current pulse input goes to the SP720 V- pin. The V+ to Vsupply of the SP720 must be allowed to float. (i.e., It is not tied
to the ground reference of the current pulse generator.)
VARIABLE TIME DURATION
CURRENT PULSE GENERATOR
R1
+
VX
CURRENT
SENSE
-
(-)
(+)
TABLE 3. SP720 TESTS TO IEC 1000-4-2 VOLTAGE LEVELS
LEVEL
Level 1
VOLTAGE
PEAK CURRENT
0.7ns TO 1ns
RISE TIME,
MEASURED
PEAK CURRENT
0.7ns TO 1ns
RISE TIME,
STANDARD
+2kV
-2kV
+7.5A
-8A
±7.5A
Level 2
+4kV
-4kV
+15A
-16A
±15A
Level 3
+6kV
-6kV
+22A
-22A
±22.5A
Level 4
+8kV
-8kV
-
±30A at 8kV
Level 4
plus 1kV
+9kV
-9kV
+34A
-34A
The 9kV level was measured (instead of 8kV) to verify the
extended range level of performance, which is the limit of the
test equipment. A linear increase beyond the specified
standard of 30A at 8kV would be equivalent to 33.75A at
9kV.
10-63
1 IN
V+ 16
2 IN
IN 15
3 IN
VOLTAGE
PROBE
R1 ~ 10Ω TYPICAL
VX ADJ. 10V/A TYPICAL
C1 ~ 100µF
SP720
IN 14
4 IN
IN 13
5 IN
IN 12
6 IN
IN 11
7 IN
IN 10
8 V-
IN 9
+
C1
-
FIGURE 4. TYPICAL SP720 PEAK CURRENT TEST CIRCUIT
WITH A VARIABLE PULSE WIDTH INPUT
Figure 5 shows a connected curve for each point of overstress
as defined by increased leakage in the SP720 to well over the
published limits of the data sheet. Using the similar
connection test circuit configuration, the SP723 capability is
shown on the same curve. The SP723 curve for a 15V supply
shows a capability of 10A peak current for the 10µs pulse and
4A peak current for the 1ms pulse. The complete curve for a
single pulse time up to 1 second is shown.
Application Note 9612
10
9
8
CAUTION: SAFE OPERATING CONDITIONS LIMIT THE
MAXIMUM PEAK CURRENT FOR A GIVEN
PULSE WIDTH TO BE NO GREATER THAN 75%
OF THE VALUES SHOWN ON EACH CURVE.
PEAK CURRENT (A)
7
SP720 STRESS CURVES
SP723 STRESS CURVE
6
5
4
3
15V
0V
5V
2
15V
30V
1
V+ TO V- SUPPLY
0
0.001
0.01
0.1
1
10
100
1000
PULSE WIDTH TIME (ms)
FIGURE 5. SP720 AND SP723 TYPICAL SINGLE PULSE PEAK CURRENT CURVES SHOWING THE MEASURED POINT OF
OVERSTRESS IN AMPERES vs PULSE WIDTH TIME IN MILLISECONDS (TA = 25oC)
12
11
10
CAUTION: SAFE OPERATING CONDITIONS LIMIT
THE MAXIMUM PEAK CURRENT FOR A GIVEN
PULSE WIDTH TO BE NO GREATER THAN 75%
OF THE VALUES SHOWN ON EACH CURVE.
TA = 25oC
9
V+ TO V- SUPPLY = 15V
SP721 STRESS CURVES
SP723 STRESS CURVE
PEAK CURRENT (A)
8
7
6
TA = 25oC
5
4
TA = 105o C
3
2
1
0
0.001
0.01
0.1
1
PULSE WIDTH TIME (ms)
10
100
FIGURE 6. SP721 AND SP723 TYPICAL SINGLE PULSE PEAK CURRENT CURVES SHOWING THE MEASURED POINT OF
OVERSTRESS IN AMPERES vs PULSE WIDTH TIME IN MILLISECONDS
10-64
1000
Application Note 9612
Figure 6 shows the single pulse peak current capability of
the SP721 for 105oC ambient temperature conditions. The
SP721 is an 8 pin package version of the SP720 but is
otherwise has the same short pulse width peak current
capability. The SP721 curve for 25oC is shown for
comparison. The reduction in maximum peak current
attributed to an increase of ambient temperature from 25oC
to 105oC is typically 10%. The overall effect of increased
chip temperature, whether by ambient temperature increase
or current induced dissipation, is to reduce the peak current
ratings. The maximum rated operating ambient temperature
for both the SP720 and SP721 is 105oC.
Multiple Pin Input Peak Current Test Evaluation
Uniformity of design and processing in the SP720 provides
the capability to use multiple pins for added input protection.
The very short pulse test capability for the dual pins is
approximately twice the peak current for a single pin.
However, for the 100ms to 1000ms pulses, the dual pin peak
current stress capability decreases, approaching that of the
single pin level. The longer pulse condition is limited by the
heat capacity of the chip and eventually forces a more rapid
increase in the chip temperature.
Other Transient Conditions
Conducted Susceptibility to Transients
Conducted Susceptibility to Transients is a test defined by
the automotive SAE J1113 standard. The waveform used to
test devices simulates the transient caused by a parallel or
series inductive load when the supply current is switched off.
Figure 7 illustrates the pulse waveforms generated by a
Schaffner 5000 Transient Pulse Test Generator used to test
the SP720. For the purposes of this test, Test Pulse 1 and 2
were applied while the V+ and V- voltage to the SP720 was
at ground. Destructive level testing at room temperature was
conducted with a single 200µs pulse while applying the
transient signal to each IN input pin. It should be noted that
the width for the 200µs pulse is defined for the 10% turn-on
levels. The sourced voltage from the generator, VS , was
varied while the peak current was monitored.
Test Results for Single Pin Testing
Up to 10 consecutive pulses were applied at a 5 second rate
to verify the transient capability of each input. It was
determined that levels of +5.5A and -8A were sufficient to
damage the inputs. Peak current levels of +5A (+6.5V) and
V
t2
t3
V+
V(GND)
t
10%
10% of PEAK; REF. 0V
VS
90%
S
SP720 TEST CONDITIONS:
T
t1
t1
V
T
S
90%
V+ = V- = 0V
VS = TRANSIENT PEAK VOLTAGE, VARIED
RI = 10Ω TRANSIENT SOURCE IMPEDANCE
t = 200µs
S = 80V/µs
t1 = 0.5s TO 5s
t2 = 0.2
t3 = TIME BETWEEN SUPPLY
SWITCH OFF AND PULSE
(TYPICALLY ≤ 100µs)
VS
10% of PEAK; REF. 0V
10%
V+
t
V(GND)
t2
FIGURE 7. TRANSIENT INDUCTIVE DISCHARGE VOLTAGE vs TIME WAVEFORMS APPLIED TO THE SP720 INPUT ‘IN’ PINS. THE TOP
WAVEFORM IS APPLIED FOR THE A DUT IN PARALLEL WITH AN INDUCTIVE LOAD AND THE BOTTOM WAVEFORM IS
APPLIED FOR SERIES CONNECTED POWER TURN-OFF (REF. SAE J1113 STANDARD)
10-65
Application Note 9612
-7A (-6V) were found to be a marginal safe level for single
pulses applied to the IN inputs.
SP723 Test Results: The short circuit current marginal point
of overstress at room temperature was determined to be:
Test Results for Double Pin Testing
For +IN Positive Surge Polarity (upper unit):
VCC = 6V
Typically greater than 9.8A
VCC = 15V
Typically greater than 9.5A
VCC = 35V
Typically greater than 9A
It was determined that paralleling input pins will permit twice the
single pin current capability. Sustained testing at a 2Hz rate was
done after paralleling pins 1+2, 3+5 and 6+7. The results for a
+10A, 200µs positive transient current pulse were:
1+2
3+5
6+7
Device 2 Failed at
PINS IN PARALLEL
-
3500
5600
Pulses
Device 3 Failed at
1150
230
340
Pulses
Sustained safe peak current levels should be no more than
70% of the point of overstress. At higher ambient
temperature up to the maximum rated conditions of 105oC,
the allowed maximum peak current should be further
reduced by at least 10%.
SP720 and SP723 Surge Immunity Test Capability
per the 8/20µs Short Circuit Conditions of IEC
1000-4-5
While the IEC 1000-4-5 is a standard that generally implies
higher levels of power than recommended for the SP720 and
SP723, testing was done to determine the comparable level
of capability. The test circuit conditions for an 8/20µs short
circuit current pulse are shown in Figures 8A and 8B. It
should be noted that the 8/20µs pulse is defined as 20µs
wide from a delayed turn-on to a 50% turn-off.
For -IN Negative Surge Polarity (lower unit):
VCC = 6V
Typically greater than 11.7A
VCC = 15V
Typically greater than 11.1A
Typically greater than 10.6A
VCC = 35V
As previously noted, sustained safe peak current levels
should be no more than 70% of the point of overstress. At
higher ambient temperature up to the maximum rated
conditions of 105oC, the allowed maximum peak current
should be further reduced by at least 10%.
RC CHARGING RESISTOR
CC ENERGY STORAGE CAPACITOR
RS1, RS2 PULSE SHAPING RESISTORS
LR RISETIME SHAPING INDUCTOR
RC
HIGH
VOLTAGE
+
-
RM
CC
RS1
LR
EUT
OR
DUT
RS2
FIGURE 8A. CIRCUIT DIAGRAM OF GENERATOR FOR 8/20µs
PULSE WAVEFORM
SP720 Test Results: The short circuit current marginal point
of overstress at room temperature was determined to be:
For -IN Negative Surge Polarity (lower unit):
VCC = 15V
Typically greater than 5.8A
VCC = 35V
Typically greater than 5.8A
As previously noted, paralleling pins on the SP720 will
increase the current capability to approximately twice that of
a single IN pin.
FRONT TIME: t1 = 1.25xt = 8µs ±20%
TIME TO HALF VALUE: t2 = 20µs ±20%
1.0
0.9
CURRENT
For +IN Positive Surge Polarity (upper unit):
VCC = 6V
Typically greater than 5A
Typically greater than 4.8A
VCC = 15V
VCC = 35V
Typically greater than 4.2A
0.5
t2
0.1
0.0
t
TIME
<30%
t1
FIGURE 8B. WAVE SHAPE FOR 8/20µs SHORT CIRCUIT
CURRENT PULSE PER IEC 60-1
10-66