ICPTest_P4KE pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
P4KE Series
Product #:
DO – 41 - TVS Diode
Issue Date:
August 15, 2011
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive
2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued by:
< Global EHS Engineer>
(1) Parts, sub-materials and unit parts
This document covers the P4KE RoHS-Compliant series products manufactured by
Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:RoHS Exemptions 5 (7C-1 in the New RoHS exemptions) and 7a apply to
these products.
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
7
8
9
10
11
Raw Material Part Number
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Raw Material Description
Chip
Silicon Wafer with Nickel plating
Wafer Passivation
Lead Wire
Solder Wafer
Copper Spacer
Epoxy Molding Compound
Tin Plating
UV Ink - RoHS
UV Ink - Pthalates
UV Ink - HBCDD
2
Page(s)
3-7
8-12
13-19
20-23
24-29, 30-35
36-39
40-46
47-52
53-59
60-62
63-66
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG
INDUSTRIAL PARK WUXI NATIONAL HIGH-TECH
DEVELOPMENT ZONE, WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
WUXH00005706S1
Date :
Aug 10, 2011
THIS IS TO SUPERSEDE REPORT
NO. WUXH00005706 DATED
AUG 04, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Silvery Grey Metal.
Item Name
: Chip.
Vendor
: Littelfuse Concord.
Component Or Part No.
: Silicon+Nickel+Glass.
Test Item
: Cd,Pb,Hg,CrVI,PBBs,PBDEs.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
1 RoHS Directives Test
(A) Test Result Summary:
Testing Item
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI) (Cr6+) Content (mg/kg)(For Non-Metal)
Polybrominated Biphenyls (PBBs)(mg/kg)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)(mg/kg)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
WUXH00005706S1
Result
ND
6110
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remark:
mg/kg = Milligram Per Kilogram = ppm
ND = Not Detected
Page 2 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
(B)RoHS Requirement:
Restricted Substances
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Chromium (VI) (Cr6+)
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ethers (PBDEs)
The Above Limits Were Quoted From 2002/95/EC And Amendment
2005/618/EC For Homogeneous Material.
WUXH00005706S1
Limits
0.01% (100 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Non-Metal)
Polybrominated Biphenyls
(PBBs)& Polybrominated
Diphenyl Ethers (PBDEs)
Reporting Limit
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Alkaline Digestion And Determined By UV-VIS
Spectrophotometer
With Reference To IEC IEC 62321 Edition 1.0: 2008,
By Solvent Extraction And Determined By GC/MS And
Further HPLC Confirmation When Necessary.
2 mg/kg
2 mg/kg
2 mg/kg
1 mg/kg
5 mg/kg
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
Page 3 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005706S1
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cd/Pb/Hg
Cr6+
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Weigh Sample
And Add
Alkaline
Solution
Confirm The Tested
Samples Are Totally
Dissolved
No
Polymers /
Electronics
Weigh Sample
And Add Organic
Solvent
Soxhlet
Extraction Or
Solvent
Extraction
Definite Temp.
Extraction
Yes
Cool And Filter
The Extract
Make Up With
Deionized Water
Analyzed By ICP-OES
PBBs/PBDEs
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Concentrate The
Extract And
Make Up With
Organic Solvent
Analyzed By
GC-MSD
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Organic (Jenny Xu/Cherry Sun)
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added For Digestion
HNO3,HCL,HF,H2O2,H3BO3
HNO3,HCL,HF
HNO3,HCL,H2O2,HBF4
Page 4 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005706S1
Tests Conducted (As Requested By The Applicant)
Photo
Page 5 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG
INDUSTRIAL PARK WUXI NATIONAL HIGH-TECH
DEVELOPMENT ZONE, WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
Date :
WUXH00005703
Aug 04, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Silvery Grey Metal.
Item Name
: Silicon Wafer With Nickel Plating.
Vendor
: Concord.
Component Or Part No.
: Silicon+Nickel.
Test Item
: Cd,Pb,Hg,CrVI,PBBs,PBDEs.
Remark
: As Requested By The Applicant, Tested As A Whole And Sampled Randomly.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
1 RoHS Directives Test
(A) Test Result Summary:
Testing Item
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI) (Cr6+) Content (mg/kg)(For Non-Metal)
Polybrominated Biphenyls (PBBs)(mg/kg)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)(mg/kg)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
WUXH00005703
Result
ND
48
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remark:
mg/kg = Milligram Per Kilogram = ppm
ND = Not Detected
Page 2 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
(B)RoHS Requirement:
Restricted Substances
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Chromium (VI) (Cr6+)
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ethers (PBDEs)
The Above Limits Were Quoted From 2002/95/EC And Amendment
2005/618/EC For Homogeneous Material.
WUXH00005703
Limits
0.01% (100 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Non-Metal)
Polybrominated Biphenyls
(PBBs)& Polybrominated
Diphenyl Ethers (PBDEs)
Reporting Limit
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Alkaline Digestion And Determined By UV-VIS
Spectrophotometer
With Reference To IEC IEC 62321 Edition 1.0: 2008,
By Solvent Extraction And Determined By GC/MS And
Further HPLC Confirmation When Necessary.
2 mg/kg
2 mg/kg
2 mg/kg
1 mg/kg
5 mg/kg
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
Page 3 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005703
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Polymers /
Electronics
Weigh Sample
And Add
Alkaline
Solution
No
Weigh Sample
And Add Organic
Solvent
Soxhlet
Extraction Or
Solvent
Extraction
Definite Temp.
Extraction
Yes
Cool And Filter
The Extract
Make Up With
Deionized Water
Analyzed By ICP-OES
PBBs/PBDEs
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Concentrate The
Extract And
Make Up With
Organic Solvent
Analyzed By
GC-MSD
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Organic (Jenny Xu/Cherry Sun)
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added For Digestion
HNO3,HCL,HF,H2O2,H3BO3
HNO3,HCL,HF
HNO3,HCL,H2O2,HBF4
Page 4 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005703
Tests Conducted (As Requested By The Applicant)
Photo
Page 5 Of 5
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG INDUSTRIAL PARK
WUXI NATIONAL HIGH-TECH DEVELOPMENT ZONE,
WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
WUXH00005704S1
Date :
Aug 11, 2011
THIS IS TO SUPERSEDE REPORT
NO. WUXH00005704 DATED
AUG 05, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : White Powder.
Item Name
: Wafer Passivation.
Vendor
: Propriety.
Component Or Part No.
: Propriety.
Test Item
: Cd,Pb,Hg,CrVI,PBBs,PBDEs,F,Cl,Br,I.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
1 RoHS Directives Test
(A) Test Result Summary:
Testing Item
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI) (Cr6+) Content (mg/kg)(For Non-Metal)
Polybrominated Biphenyls (PBBs)(mg/kg)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)(mg/kg)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
WUXH00005704S1
Result
ND
185100
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remark:
mg/kg = Milligram Per Kilogram = ppm
ND = Not Detected
#=The Result Is For Reference Only.
Page 2 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
(B)RoHS Requirement:
Restricted Substances
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Chromium (VI) (Cr6+)
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ethers (PBDEs)
The Above Limits Were Quoted From 2002/95/EC And Amendment
2005/618/EC For Homogeneous Material.
WUXH00005704S1
Limits
0.01% (100 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Non-Metal)
Polybrominated Biphenyls
(PBBs)& Polybrominated
Diphenyl Ethers (PBDEs)
Reporting Limit
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Alkaline Digestion And Determined By UV-VIS
Spectrophotometer
With Reference To IEC IEC 62321 Edition 1.0: 2008,
By Solvent Extraction And Determined By GC/MS And
Further HPLC Confirmation When Necessary.
2 mg/kg
2 mg/kg
2 mg/kg
1 mg/kg
5 mg/kg
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
Page 3 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005704S1
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Polymers /
Electronics
Weigh Sample
And Add
Alkaline
Solution
No
Weigh Sample
And Add Organic
Solvent
Soxhlet
Extraction Or
Solvent
Extraction
Definite Temp.
Extraction
Yes
Cool And Filter
The Extract
Make Up With
Deionized Water
Analyzed By ICP-OES
PBBs/PBDEs
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Concentrate The
Extract And
Make Up With
Organic Solvent
Analyzed By
GC-MSD
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Organic (Jenny Xu/Cherry Sun)
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
2
Acid Added For Digestion
HNO3,HCL,HF,H2O2,H3BO3
HNO3,HCL,HF
HNO3,HCL,H2O2,HBF4
Halogen Test
(I) Test Result Summary :
Page 4 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005704S1
Tests Conducted (As Requested By The Applicant)
Halogen Content:
Result (ppm)
Testing Item
Fluorine (F) Content
Chlorine (Cl)Content
Bromine (Br) Content
Iodine (I) Content
ND
ND
ND
ND
Remarks : ppm = Parts Per Million = mg/kg
ND = Not Detected
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 05, 2011
(II) Test Method :
Testing Item
Testing Method
With Reference To EN 14582:2007 By Combustion In A
Calorimetric Bomb And Determined By Ion Chromatography
Remarks : Reporting Limit = Quantitation Limit Of Analyte In Sample
Halogen (F, Cl, Br, I) Content
Reporting Limit
50 ppm
Page 5 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005704S1
Tests Conducted (As Requested By The Applicant)
(III) Measurement Flowchart:
Test For Halogen Content Reference Method: EN 14582:2007
Sampling/Grinding Or Cutting
Add Absorbent In A Combustion Flask & Place
Weighed Sample In
Fill The Calorimetric Bomb With Oxygen
Ignite Then Leave The Flask At Room
Temperature
Any Test Specimen In The Olorimetric Bomb?
Yes
No
Transfer The Absorbent Into A Volumetric
Flask
Make Up With Deionized Water
Analyzed By Ion Chromatography
Chemist: Fred Wang/ Ally Wan Ally Wan
Page 6 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005704S1
Tests Conducted (As Requested By The Applicant)
Photo
Page 7 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG INDUSTRIAL PARK
WUXI NATIONAL HIGH-TECH DEVELOPMENT ZONE,
WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
Date :
WUXH00005708
Aug 04, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Golden Yellow Metal.
Item Name
: Lead Wire.
Vendor
: Shanghai Bontech Enterprise.
Component Or Part No.
: Alloy Copper.
Test Item
: Cd,Pb,Hg,CrVI.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Summary:
Tested Sample
Submitted Sample
Standard
With Reference To Test Method Of IEC 62321 Edition
1.0: 2008 And Maximum Concentration Limits Quoted
From RoHS Directives 2002/95/EC And Amendment
2005/618/EC
Result
PASS
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 4
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
1
RoHS Directives Test
(A) Test Result Summary:
Testing Item
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI)(Cr6+) Result (By Boiling Water Extraction On
Metal) (mg/kg With 50cm2)
WUXH00005708
Result
ND
ND
ND
N
Remark:
mg/kg = Milligram Per Kilogram = ppm
mg/kg With 50cm2 = Milligram Per Kilogram With 50 Square Centimeter
ND = Not Detected
N=Negative
(B)RoHS Requirement:
Restricted Substances
Limits
Cadmium (Cd)
0.01% (100 mg/kg)
Lead (Pb)
0.1% (1000 mg/kg)
Mercury (Hg)
0.1% (1000 mg/kg)
Chromium (VI) (Cr6+)
0.1% (1000 mg/kg)
The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material.
(C) Test Method:
Testing Method
Testing Item
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
Lead (Pb)Content
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
Mercury (Hg)Content
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
6+
Chromium (VI) (Cr ) Content
Boiling Water Extraction And Determined By UV-VIS
(For Metal)
Spectrophotometer
Cadmium (Cd)Content
Reporting Limit
2 mg/kg
2 mg/kg
2 mg/kg
0.02mg/kg With
50cm2
(In Testing Solution)
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 03, 2011
Page 2 Of 4
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005708
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
Metal
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Spot Test
Positive*2
Get 50cm2
Samples
No
Yes
Boiling Water
Extraction
Make Up With
Deionized Water
Analyzed By ICP-OES
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Remarks:
*1: List Of Appropriate Acid:
Material
Acid Added For Digestion
Polymers
HNO3,HCL,HF,H2O2,H3BO3
Metals
HNO3,HCL,HF
Electronics
HNO3,HCL,H2O2,HBF4
*2: If The Result Of Spot Test Is Positive, Chromium VI Would Be Determined As Detected.
Page 3 Of 4
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
WUXH00005708
Photo
Page 4 Of 4
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG
INDUSTRIAL PARK WUXI NATIONAL HIGH-TECH
DEVELOPMENT ZONE, WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
Date :
WUXH00005732
Aug 05, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Silver Metal.
Item Name
: Solder Wafer.
Vendor
: Jin Zhou Rongheng Electronics Co.
Component Or Part No.
: Pb:Sn:Ag=92.5:5:2.5.
Test Item
: Cd,Pb,Hg,CrVI,F,Cl,Br,I.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005732
Tests Conducted (As Requested By The Applicant)
1
RoHS Directives Test
(A) Test Result Summary:
Testing Item
Result
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI)(Cr6+) Result (By Boiling Water Extraction On
Metal) (mg/kg With 50cm2)
ND
901600
ND
N
Remark:
mg/kg = Milligram Per Kilogram = ppm
mg/kg With 50cm2 = Milligram Per Kilogram With 50 Square Centimeter
ND = Not Detected
N=Negative
#=The Result Is For Reference Only.
(B)RoHS Requirement:
Restricted Substances
Limits
Cadmium (Cd)
0.01% (100 mg/kg)
Lead (Pb)
0.1% (1000 mg/kg)
Mercury (Hg)
0.1% (1000 mg/kg)
Chromium (VI) (Cr6+)
0.1% (1000 mg/kg)
The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous
Material.
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Metal)
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Boiling Water Extraction And Determined By UV-VIS
Spectrophotometer
Reporting Limit
2 mg/kg
2 mg/kg
2 mg/kg
0.02mg/kg With
50cm2
(In Testing Solution)
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
Page 2 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005732
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
Metal
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Spot Test
Positive*2
Get 50cm2
Samples
No
Yes
Boiling Water
Extraction
Make Up With
Deionized Water
Analyzed By ICP-OES
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Remarks:
*1: List Of Appropriate Acid:
Material
Acid Added For Digestion
Polymers
HNO3,HCL,HF,H2O2,H3BO3
Metals
HNO3,HCL,HF
Electronics
HNO3,HCL,H2O2,HBF4
*2: If The Result Of Spot Test Is Positive, Chromium VI Would Be Determined As Detected.
Page 3 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005732
Tests Conducted (As Requested By The Applicant)
2
Halogen Test
(I) Test Result Summary :
Halogen Content:
Result (ppm)
Testing Item
Fluorine (F) Content
Chlorine (Cl)Content
Bromine (Br) Content
Iodine (I) Content
ND
ND
ND
ND
Remarks : ppm = Parts Per Million = mg/kg
ND = Not Detected
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
(II) Test Method :
Testing Item
Testing Method
With Reference To EN 14582:2007 By Combustion In A
Calorimetric Bomb And Determined By Ion Chromatography
Remarks : Reporting Limit = Quantitation Limit Of Analyte In Sample
Halogen (F,Cl, Br,I) Content
Reporting Limit
50 ppm
Page 4 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005732
Tests Conducted (As Requested By The Applicant)
(III) Measurement Flowchart:
Test For Halogen Content Reference Method: EN 14582:2007
Sampling/Grinding Or Cutting
Add Absorbent In A Combustion Flask & Place
Weighed Sample In
Fill The Calorimetric Bomb With Oxygen
Ignite Then Leave The Flask At Room
Temperature
Any Test Specimen In The Olorimetric Bomb?
Yes
No
Transfer The Absorbent Into A Volumetric
Flask
Make Up With Deionized Water
Analyzed By Ion Chromatography
Chemist: Fred Wang/ Ally Wan Ally Wan
Page 5 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
WUXH00005732
Photo
Page 6 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG
INDUSTRIAL PARK WUXI NATIONAL HIGH-TECH
DEVELOPMENT ZONE, WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
Date :
WUXH00005736
Aug 05, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Silver Metal.
Item Name
: Solder Wafer.
Vendor
: Coining Inc.
Component Or Part No.
: Pb:Sn=90:10.
Test Item
: Cd,Pb,Hg,CrVI,,F,Cl,Br,I.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005736
Tests Conducted (As Requested By The Applicant)
1
RoHS Directives Test
(A) Test Result Summary:
Testing Item
Result
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI)(Cr6+) Result (By Boiling Water Extraction On
Metal) (mg/kg With 50cm2)
ND
908500
ND
N
Remark:
mg/kg = Milligram Per Kilogram = ppm
mg/kg With 50cm2 = Milligram Per Kilogram With 50 Square Centimeter
ND = Not Detected
N=Negative
#=The Result Is For Reference Only.
(B)RoHS Requirement:
Restricted Substances
Limits
Cadmium (Cd)
0.01% (100 mg/kg)
Lead (Pb)
0.1% (1000 mg/kg)
Mercury (Hg)
0.1% (1000 mg/kg)
Chromium (VI) (Cr6+)
0.1% (1000 mg/kg)
The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous
Material.
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Metal)
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Boiling Water Extraction And Determined By UV-VIS
Spectrophotometer
Reporting Limit
2 mg/kg
2 mg/kg
2 mg/kg
0.02mg/kg With
50cm2
(In Testing Solution)
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 05, 2011
Page 2 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005736
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
Metal
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Spot Test
Positive*2
Get 50cm2
Samples
No
Yes
Boiling Water
Extraction
Make Up With
Deionized Water
Analyzed By ICP-OES
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Remarks:
*1: List Of Appropriate Acid:
Material
Acid Added For Digestion
Polymers
HNO3,HCL,HF,H2O2,H3BO3
Metals
HNO3,HCL,HF
Electronics
HNO3,HCL,H2O2,HBF4
*2: If The Result Of Spot Test Is Positive, Chromium VI Would Be Determined As Detected.
Page 3 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005736
Tests Conducted (As Requested By The Applicant)
2
Halogen Test
(I) Test Result Summary :
Halogen Content:
Result (ppm)
Testing Item
Fluorine (F) Content
Chlorine (Cl)Content
Bromine (Br) Content
Iodine (I) Content
ND
ND
ND
ND
Remarks : ppm = Parts Per Million = mg/kg
ND = Not Detected
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
(II) Test Method :
Testing Item
Testing Method
With Reference To EN 14582:2007 By Combustion In A
Calorimetric Bomb And Determined By Ion Chromatography
Remarks : Reporting Limit = Quantitation Limit Of Analyte In Sample
Halogen (F,Cl, Br,I) Content
Reporting Limit
50 ppm
Page 4 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005736
Tests Conducted (As Requested By The Applicant)
(III) Measurement Flowchart:
Test For Halogen Content Reference Method: EN 14582:2007
Sampling/Grinding Or Cutting
Add Absorbent In A Combustion Flask & Place
Weighed Sample In
Fill The Calorimetric Bomb With Oxygen
Ignite Then Leave The Flask At Room
Temperature
Any Test Specimen In The Olorimetric Bomb?
Yes
No
Transfer The Absorbent Into A Volumetric
Flask
Make Up With Deionized Water
Analyzed By Ion Chromatography
Chemist: Fred Wang/ Ally Wan Ally Wan
Page 5 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
WUXH00005736
Photo
Page 6 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG INDUSTRIAL PARK
WUXI NATIONAL HIGH-TECH DEVELOPMENT ZONE,
WUXI, JIANGSU ,CHINA
Attn : ZHANG XIAOPENG
Date :
WUXH00005717
Aug 04, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Silvery Metal.
Item Name
: Copper Spacer(Circle).
Vendor
: Sung Jung Minute Industry CO., LTD.
Component Or Part No.
: Copper With Ag Plating.
Test Item
: Cd,Pb,Hg,CrVI.
Remark
: As Requested By The Applicant, Tested As A Whole And Sampled Randomly.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Summary:
Tested Sample
Submitted Sample
Standard
With Reference To Test Method Of IEC 62321 Edition
1.0: 2008 And Maximum Concentration Limits Quoted
From RoHS Directives 2002/95/EC And Amendment
2005/618/EC
Result
PASS
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 4
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
1
RoHS Directives Test
(A) Test Result Summary:
Testing Item
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI)(Cr6+) Result (By Boiling Water Extraction On
Metal) (mg/kg With 50cm2)
WUXH00005717
Result
ND
ND
ND
N
Remark:
mg/kg = Milligram Per Kilogram = ppm
mg/kg With 50cm2 = Milligram Per Kilogram With 50 Square Centimeter
ND = Not Detected
N=Negative
(B)RoHS Requirement:
Restricted Substances
Limits
Cadmium (Cd)
0.01% (100 mg/kg)
Lead (Pb)
0.1% (1000 mg/kg)
Mercury (Hg)
0.1% (1000 mg/kg)
Chromium (VI) (Cr6+)
0.1% (1000 mg/kg)
The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material.
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Metal)
Reporting Limit
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
2 mg/kg
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
2 mg/kg
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
2 mg/kg
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
0.02mg/kg With 50cm2
Boiling Water Extraction And Determined By UV-VIS
(In Testing Solution)
Spectrophotometer
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 03, 2011
Page 2 Of 4
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005717
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
Metal
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Spot Test
Positive*2
Get 50cm2
Samples
No
Yes
Boiling Water
Extraction
Make Up With
Deionized Water
Analyzed By ICP-OES
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Remarks:
*1: List Of Appropriate Acid:
Material
Acid Added For Digestion
Polymers
HNO3,HCL,HF,H2O2,H3BO3
Metals
HNO3,HCL,HF
Electronics
HNO3,HCL,H2O2,HBF4
*2: If The Result Of Spot Test Is Positive, Chromium VI Would Be Determined As Detected.
Page 3 Of 4
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
WUXH00005717
Photo
Page 4 Of 4
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG INDUSTRIAL PARK
WUXI NATIONAL HIGH-TECH DEVELOPMENT ZONE,
WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
Date :
WUXH00005740
Aug 05, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Brown Epoxy Molding Compound.
Item Name
: Epoxy Molding Compound.
Vendor
: Chang Chun Plastics Co.,LTD.
Component Or Part No.
: EME-E110G.
Test Item
: Cd,Pb,Hg,CrVI,PBBs,PBDEs,F,Cl,Br,I.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Summary:
Tested Sample
Submitted Sample
Standard
With Reference To Test Method Of IEC 62321 Edition
1.0: 2008 And Maximum Concentration Limits Quoted
From RoHS Directives 2002/95/EC And Amendment
2005/618/EC
Result
PASS
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
1
RoHS Directives Test
(A) Test Result Summary:
Testing Item
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI) (Cr6+) Content (mg/kg)(For Non-Metal)
Polybrominated Biphenyls (PBBs)(mg/kg)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)(mg/kg)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
WUXH00005740
Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remark:
mg/kg = Milligram Per Kilogram = ppm
ND = Not Detected
Page 2 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005740
Tests Conducted (As Requested By The Applicant)
(B)RoHS Requirement:
Restricted Substances
Limits
Cadmium (Cd)
0.01% (100 mg/kg)
Lead (Pb)
0.1% (1000 mg/kg)
Mercury (Hg)
0.1% (1000 mg/kg)
Chromium (VI) (Cr6+)
0.1% (1000 mg/kg)
Polybrominated Biphenyls (PBBs)
0.1% (1000 mg/kg)
Polybrominated Diphenyl Ethers (PBDEs)
0.1% (1000 mg/kg)
The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous Material.
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Non-Metal)
Polybrominated Biphenyls
(PBBs)& Polybrominated
Diphenyl Ethers (PBDEs)
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By Acid
Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Alkaline Digestion And Determined By UV-VIS
Spectrophotometer
With Reference To IEC 62321 Edition 1.0: 2008, By
Solvent Extraction And Determined By GC-MSD And
Further HPLC Confirmation When Necessary.
Reporting Limit
2 mg/kg
2 mg/kg
2 mg/kg
1 mg/kg
5 mg/kg
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
Page 3 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005740
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Polymers /
Electronics
Weigh Sample
And Add
Alkaline
Solution
No
Weigh Sample
And Add Organic
Solvent
Soxhlet
Extraction Or
Solvent
Extraction
Definite Temp.
Extraction
Yes
Cool And Filter
The Extract
Make Up With
Deionized Water
Analyzed By ICP-OES
PBBs/PBDEs
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Concentrate The
Extract And
Make Up With
Organic Solvent
Analyzed By
GC-MSD
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Organic (Jenny Xu/Cherry Sun)
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added For Digestion
HNO3,HCL,HF,H2O2,H3BO3
HNO3,HCL,HF
HNO3,HCL,H2O2,HBF4
Page 4 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005740
Tests Conducted (As Requested By The Applicant)
2
Halogen Test
(I) Test Result Summary :
Halogen Content:
Testing Item
Fluorine (F) Content
Chlorine (Cl)Content
Bromine (Br) Content
Iodine (I) Content
Result (ppm)
ND
ND
ND
ND
Remarks : ppm = Parts Per Million = mg/kg
ND = Not Detected
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
(II) Test Method :
Testing Item
Testing Method
With Reference EN 14582:2007 By Combustion In A
Calorimetric Bomb And Determined By Ion Chromatography
Remarks : Reporting Limit = Quantitation Limit Of Analyte In Sample
Halogen (F,Cl, Br,I) Content
Reporting
Limit
50 ppm
Page 5 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005740
Tests Conducted (As Requested By The Applicant)
(III) Measurement Flowchart:
Test For Halogen Content Reference Method: EN 14582:2007
Sampling/Grinding Or Cutting
Add Absorbent In A Combustion Flask & Place
Weighed Sample In
Fill The Calorimetric Bomb With Oxygen
Ignite Then Leave The Flask At Room
Temperature
Any Test Specimen In The Olorimetric Bomb?
Yes
No
Transfer The Absorbent Into A Volumetric
Flask
Make Up With Deionized Water
Analyzed By Ion Chromatography
Chemist: Fred Wang/ Ally Wan Ally Wan
Page 6 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
WUXH00005740
Photo
Page 7 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG
INDUSTRIAL PARK WUXI NATIONAL HIGH-TECH
DEVELOPMENT ZONE, WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
Date :
WUXH00005716
Aug 04, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Black Plastic With Silvery Metal Pin.
Item Name
: Tin Plating-Axial.
Vendor
: Zhangjiagang Liangshen Plating Co.,.
Component Or Part No.
: Pure Matte Tin.
Test Item
: Cd,Pb,Hg,CrVI,F,Cl,Br,I.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005716
Tests Conducted (As Requested By The Applicant)
1
RoHS Directives Test
(A) Test Result Summary:
Testing Item
Cadmium (Cd) Content (mg/kg)/Plating
Lead (Pb) Content (mg/kg)/Plating
Mercury (Hg) Content (mg/kg)/Plating
Chromium (VI)(Cr6+) Result (By Boiling Water Extraction On
Metal) (mg/kg With 50cm2)
Result
(1)
ND
68
ND
N
Remark:
mg/kg = Milligram Per Kilogram = ppm
mg/kg With 50cm2 = Milligram Per Kilogram With 50 Square Centimeter
ND = Not Detected
N=Negative
Tested Component:
(1) Metal Pin Plating.
(B)RoHS Requirement:
Restricted Substances
Limits
Cadmium (Cd)
0.01% (100 mg/kg)
Lead (Pb)
0.1% (1000 mg/kg)
Mercury (Hg)
0.1% (1000 mg/kg)
Chromium (VI) (Cr6+)
0.1% (1000 mg/kg)
The Above Limits Were Quoted From 2002/95/EC And Amendment 2005/618/EC For Homogeneous
Material.
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Metal)
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Boiling Water Extraction And Determined By UV-VIS
Spectrophotometer
Reporting Limit
2 mg/kg
2 mg/kg
2 mg/kg
0.02mg/kg With
50cm2
(In Testing Solution)
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
Page 2 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005716
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
Metal
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Spot Test
Positive*2
Get 50cm2
Samples
No
Yes
Boiling Water
Extraction
Make Up With
Deionized Water
Analyzed By ICP-OES
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Remarks:
*1: List Of Appropriate Acid:
Material
Acid Added For Digestion
Polymers
HNO3,HCL,HF,H2O2,H3BO3
Metals
HNO3,HCL,HF
Electronics
HNO3,HCL,H2O2,HBF4
*2: If The Result Of Spot Test Is Positive, Chromium VI Would Be Determined As Detected.
Page 3 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005716
Tests Conducted (As Requested By The Applicant)
2
Halogen Test
(I) Test Result Summary :
Halogen Content:
Result (ppm)
Testing Item
(2)
Fluorine (F) Content
Chlorine (Cl)Content
Bromine (Br) Content
Iodine (I) Content
ND
94
ND
ND
Remarks : ppm = Parts Per Million = mg/kg
ND = Not Detected
Tested Component:
(2) Black Plastic.
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
(II) Test Method :
Testing Item
Testing Method
With Reference To EN 14582:2007 By Combustion In A
Calorimetric Bomb And Determined By Ion Chromatography
Remarks : Reporting Limit = Quantitation Limit Of Analyte In Sample
Halogen (F,Cl, Br,I) Content
Reporting Limit
50 ppm
Page 4 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005716
Tests Conducted (As Requested By The Applicant)
(III) Measurement Flowchart:
Test For Halogen Content Reference Method: EN 14582:2007
Sampling/Grinding Or Cutting
Add Absorbent In A Combustion Flask & Place
Weighed Sample In
Fill The Calorimetric Bomb With Oxygen
Ignite Then Leave The Flask At Room
Temperature
Any Test Specimen In The Olorimetric Bomb?
Yes
No
Transfer The Absorbent Into A Volumetric
Flask
Make Up With Deionized Water
Analyzed By Ion Chromatography
Chemist: Fred Wang/ Ally Wan Ally Wan
Page 5 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
WUXH00005716
Photo
Page 6 Of 6
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Applicant :
CONCORD SEMICONDUCTOR(WUXI) CO., LTD.
EAST 1#,ZHENFA 6 ROAD, SHUO FANG
INDUSTRIAL PARK WUXI NATIONAL HIGH-TECH
DEVELOPMENT ZONE, WUXI,JIANGSU,CHINA
Attn : ZHANG XIAOPENG
Date :
WUXH00005743
Aug 05, 2011
Sample Description As Declared:
One (1) Piece Of Submitted Sample Said To Be : Silvery Ink.
Item Name
: UV Ink.
Vendor
: Bon Mark.
Test Item
: Cd,Pb,Hg,CrVI,PBBs,PBDEs,F,Cl,Br,I.
Tests Conducted:
As Requested By The Applicant, For Details Refer To Attached Pages
Summary:
Tested Sample
Submitted Sample
Standard
With Reference To Test Method Of IEC 62321 Edition
1.0: 2008 And Maximum Concentration Limits Quoted
From RoHS Directives 2002/95/EC And Amendment
2005/618/EC
Result
PASS
Prepared And Checked By:
For Intertek Testing Services Wuxi Ltd.
Jessica Lu
General Manager
Page 1 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
1 RoHS Directives Test
(A) Test Result Summary:
Testing Item
Cadmium (Cd) Content (mg/kg)
Lead (Pb) Content (mg/kg)
Mercury (Hg) Content (mg/kg)
Chromium (VI) (Cr6+) Content (mg/kg)(For Non-Metal)
Polybrominated Biphenyls (PBBs)(mg/kg)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)(mg/kg)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
WUXH00005743
Result
ND
21
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
Remark:
mg/kg = Milligram Per Kilogram = ppm
ND = Not Detected
Page 2 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
(B)RoHS Requirement:
Restricted Substances
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Chromium (VI) (Cr6+)
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ethers (PBDEs)
The Above Limits Were Quoted From 2002/95/EC And Amendment
2005/618/EC For Homogeneous Material.
WUXH00005743
Limits
0.01% (100 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
(C) Test Method:
Testing Method
Testing Item
Cadmium (Cd)Content
Lead (Pb)Content
Mercury (Hg)Content
Chromium (VI) (Cr6+)
Content (For Non-Metal)
Polybrominated Biphenyls
(PBBs)& Polybrominated
Diphenyl Ethers (PBDEs)
Reporting Limit
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Acid Digestion And Determined By ICP-OES
With Reference To IEC 62321 Edition 1.0: 2008, By
Alkaline Digestion And Determined By UV-VIS
Spectrophotometer
With Reference To IEC IEC 62321 Edition 1.0: 2008,
By Solvent Extraction And Determined By GC/MS And
Further HPLC Confirmation When Necessary.
2 mg/kg
2 mg/kg
2 mg/kg
1 mg/kg
5 mg/kg
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 04, 2011
Page 3 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005743
Tests Conducted (As Requested By The Applicant)
(D) Measurement Flowchart:
Reference Standard: IEC 62321 Edition 1.0: 2008
Sampling/Grinding Or Cutting
Cr6+
Cd/Pb/Hg
For Different Material,
Digest The Sample
With Appropriate
Acid*1
Confirm The Tested
Samples Are Totally
Dissolved
Polymers /
Electronics
Weigh Sample
And Add
Alkaline
Solution
No
Weigh Sample
And Add Organic
Solvent
Soxhlet
Extraction Or
Solvent
Extraction
Definite Temp.
Extraction
Yes
Cool And Filter
The Extract
Make Up With
Deionized Water
Analyzed By ICP-OES
PBBs/PBDEs
Make Up With Deionized
Water And Add DiphenylCarbazide Solution
Concentrate The
Extract And
Make Up With
Organic Solvent
Analyzed By
GC-MSD
Analyzed By UV-VIS
Chemist: Inorganic (Ann Luo/Fred Wang/Ally Wan)
Organic (Jenny Xu/Cherry Sun)
Remarks:
*1: List Of Appropriate Acid:
Material
Polymers
Metals
Electronics
2
Acid Added For Digestion
HNO3,HCL,HF,H2O2,H3BO3
HNO3,HCL,HF
HNO3,HCL,H2O2,HBF4
Halogen Test
(I) Test Result Summary :
Page 4 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005743
Tests Conducted (As Requested By The Applicant)
Halogen Content:
Result (ppm)
Testing Item
Fluorine (F) Content
Chlorine (Cl)Content
Bromine (Br) Content
Iodine (I) Content
126
ND
ND
ND
Remarks : ppm = Parts Per Million = mg/kg
ND = Not Detected
Date Sample Received: Aug 01, 2011
Testing Period: Aug 01, 2011 To Aug 05, 2011
(II) Test Method :
Testing Item
Testing Method
With Reference To EN 14582:2007 By Combustion In A
Calorimetric Bomb And Determined By Ion Chromatography
Remarks : Reporting Limit = Quantitation Limit Of Analyte In Sample
Halogen (F,Cl, Br,I) Content
Reporting Limit
50 ppm
Page 5 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
WUXH00005743
Tests Conducted (As Requested By The Applicant)
(III) Measurement Flowchart:
Test For Halogen Content Reference Method: EN 14582:2007
Sampling/Grinding Or Cutting
Add Absorbent In A Combustion Flask & Place
Weighed Sample In
Fill The Calorimetric Bomb With Oxygen
Ignite Then Leave The Flask At Room
Temperature
Any Test Specimen In The Olorimetric Bomb?
Yes
No
Transfer The Absorbent Into A Volumetric
Flask
Make Up With Deionized Water
Analyzed By Ion Chromatography
Chemist: Fred Wang/ Ally Wan Ally Wan
Page 6 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
Number :
TEST REPORT
Tests Conducted (As Requested By The Applicant)
WUXH00005743
Photo
Page 7 Of 7
Intertek Testing Services Wuxi Ltd.
No.8 Fubei Road, Xishan Economic Development Zone,
Wuxi 214101, Jiangsu, China
Tel: +86 510 8821 4567 Fax: +86 510 8820 0428 E-mail: [email protected]
00 032 56
NUMBER:WUXHo
TEST REPORT
APPLICANT:
(WUXI) Co.,
CONCORDSEMICONDUCTOR
LTD.
EAST 1#, ZHENFA 6 ROAD, SHUO FANG
INDUSTRIAI, PARK WIIXI NATIONAI, HIGHTECH DEVELOPMENT ZONE.
WIIXI , JIANGSU, CHINA
ATTN: ZHANG XIAOPENG
DATE: OCT 11,
2010
SAMPI.E DESCRIPTION:
ONE(1) PTECE OF STIBMITTED SAMPLE SAID TO BE : SII,VER IIR.
: UV INK(PRODUCEDBY BON MARK).
ITEM NAME
TESTS CONDUCTED:
AS REOIJESTED BY THE APPLICANT,
FOR DBTAILS
REFER TO ATTACHED PAGE(S)
TO BE COI{TINIJED
PREPARED AND CITECKED BY:
FOR INTERTEK TESTING SERVICES WIIXI LTD
.-]ESSICA I,U
GENERAI, MANAGER
PAGE 1 OF 3
IntertekTestlngSorvlcesWuxiLtd.
No.3 Fub.i Red Xsh.n Edomic D.\[email protected] Zoi..
wu 214101,Jian!$. chin.
+a6s103321
Td
4s67 Fd:.36510$m0a23
E-m.lt:63umeEo.ds.*0r@iitertok.@m
TEST REPORT
NUMBER: WIIXHo0003256
TESTS CONDUCTED
PHTIAI.ATE
CONTEIfI
TEST
WITH REFERENCETO 8N14372, BY GAS CHROMATOGRAPHIC-MASS
SPECTROMETRIC (GC.MS) ANAI,YS]S.
TESTED COMPOI'ND
RESULT ( *, W/W)
DIBUIYL PHTTIAI.ATE(DBP)
DIETHYL HEXYL PHTTIALATE
{DEHP)
BENZYL BI]IYL PHTIALATE {BBP)
ND
ND
ND
DI-ISO.NONYI,
PHTIAI.ATE (DINP)
DI-N.OCTY],
PHTI{AI,ATE {DNOP)
DI-ISO-DECYI
PI{TIAI,ATE (DIDP)
ND
ND
ND
REMARK :
LIMIT (*, W/W)
(MAX. )
THE ABOVE LIMIT WAS OUOTED ACCORDING TO ANNEX XVI]
ITEMS 51 & 52 OF THE REACH REGULATION (EC) NO.
(FORMERLYKNOWNAS DIRBCTIVE 2OO5/84/BCJ FOF'
I9O7/2006
PHTITAI,ATE CONTENT IN TOYS AND CHILDRBN CARE ARTICLES.
D E T E C T I O NL T M I T =
ND = NOT DETECTED
0.018 (W/W)
DATE SAMPLE RECEIVED : SEP 29. 2010
TESTTNG PERIOD : SEp 29, 2010 TO OCT 8.
2O1O
TO BE COI\I'IINUED
IntertekTeatlngServicosWuxtLtd.
No.8Fubri R@d,xtah.n Eomic D.v€topmoitzon..
wqi214r0t J6no.u,ChrE
T.r.+3651033214567
F.r +A€s1033200423 E-ro,t @n.JrBgo.dswu.@,{cn6ksn
PAGE 2 OF 3
NUMBER:wItXHo0003256
TEST REPORT
TESTS CONDUCTED
PHOTO
END OF REPORT
PAGE 3 0 F 3
htertekT6tlng ServicesWurl Ltd.
No.8 Fub.i Red X5h€h Eonomic O.vdopm.nl Zone
wwj214101, Ji.ng&, Chin.
T.l +355103a2145€7 Fd: +36 s10 s€200423 E-mailtrsum.l9oods.rul(lintdtok.@m
TEST REPORT
APPLICANT:
NIUMBER:
CONCORDSEMICONDUCTOR
(WUXI) CO.,
LTD.
EAST 1#, ZHENFA 5 ROAD, SHUO FANG
INDUSTRIAL PARK WUX] NATIONAL
HIGH-TECH DEVELOPMEMI ZONE,
WTIXI, J]ANGSU, CHINA
ATTN: ZHANG XIAOPENG
DATE: NOV 04, 2010
SAI,IPLE DESCRIPTION :
ONE(1) PIECE OF SUBMITTED SAMpl,E SAID TO BE :SILVER Iw
ITEM NAMB
: UV INK.
VEI.rDOR
: BONMARK.
TESTS CONDUCTED:
AS REOUESTED BY THE APPLICANT,
FOR DETAILS
wuxHo0003471
INK.
REFER TO ATTACHED PAGE(S)
TO BE CONTINUED
PREPARED AND CHECKED BY:
FOR TNTERTEK TESTING SERVICES WUXI LTD.
.IESS]CA ],U
GENERAL MANAGER
PAGE 1 OF 4
IntertekTestingServlcesWuxiLtd.
No.8 Fubr! R@d Xishan Eonomic D.v€loomenl zon.
wu1214101, Jian!$. China
E-mailrtrsum.Eoods wuxi@iibn€k @f,
TEST RBPORT
NUMBER: W(IXHo00 034 ?1
TESTS CONDUCTED
(A)
TEST RESULT SUMMARY:
RESULT(ppn)
TESTING ITEM
ND
HBCD (HEXABROMOCYCLODODECANE)
REMARKS:
ppm = PARTS PER MILITON
ND = NOT DETECTED
= mglkg
(B) TEST METHOD :
TESTINC ITEM
REPORTlNG
LIMIT
TSSTING METHOD
WITH REFERENCE TO USEPA
HBCD (HEXABROMOCYCI,ODODECANE)
3540C. BY SOI,VENT EXTRACTION
AND DETERMINED BY GCIMS
DATE SAMPITERECEMD
|OCT 29,2010
TESTING PERIOD: OCI 29,2Ol-O TO NOV 3,
10 ppm
2010
TO BE CONTINUED
PAGE 2 OF 4
IntertekTestingServicesWuxlLtd.
c Dov€roN.ntZo.,
Wun2 r01.Jianssu,
Chnd
E_roil:@nsumaoodswd@idetuk 6m
TBST REPORT
NUMBER: WIIXHo00 0 34 71
TESTS CONDUCTED
MEASUREMENT FIJOWCHART:
TEST FOR HBCD (Hexabromocyclododecane
) CONTENT
Weigh sample and place
into a thimble
o
Soxhlet
extraction
^rdrh
i ^
wilh
e^]r'anr
{]
Concentrate
the extract
o
Transfer the extract
inEo a volumetric
flask
tr
Make up with organic
solvent
o
Analyze
by GC-MSD
TO BE CONTINUED
PAGE 3 0 F 4
InteitekTestlngServicesWuxi Lld.
No 3 Fub€iR@q xsh€h EonomicD.vdopne zono
wur214101.Ji€ng{.China
E-m€il@[email protected].@
TEST RBPORT
NUMBER:WUXHo0
0 034 71
TESTS CONDUCTED
PHOTO
END OF REPORT
PAGE 4 0 F 4
IntortekTestingSe icesWuxlLtd.
No.3 Fob€i Ro.d, XEh.n Eonmic Oov€lopmcnrZon..
wdj 214101,Jr.ng&, Chin.
Tei +36510 33214567 Fd:+36510$mq23
E mall:6sum.qoods.wul@inldlok @m