ICPTest_877_06 03 2013 pdf

ICP Test Report Certification Packet
Company name :
Littelfuse, Inc.
Product Series:
Compact 3.6 x 10 mm Single Pigtail Fuse
Product #:
877xxx Series
Issue Date:
June 03, 2013
It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC,
2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for
packing/packaging materials, and for additives and the like in the manufacturing processes.
In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used
for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing
processes, are all composed of the following components.
Issued :
<Global EHS Specialist >
(1) Parts, sub-materials and unit parts
This document covers the Compact 3.6 x 10 mm Single Pigtail Fuse, RoHS-Compliant
series products manufactured by Littelfuse, Inc.
< Raw Materials Used
Please see Table 1
(2) The ICP data on all measurable substances
Please see appropriate pages as identifed in Table 1
Remarks:
Form 585-047 Rev. A
1
2/21/06
Table 1: List of Raw Materials covered by this report
Total Parts
1
2
3
4
5
6
Raw Material Part Number
YJ50/YJM (909-444)
692481
934-065
7132 (425672)
DRAG****
648112-001
Raw Material Description
Ceramic Base - Body
Solder
Cap & Lead wire (base & plating)
Ink-Black
Element - Wire-Sn Plated Ag/Cu
Ceramic Yarn
2
Page(s)
3-9
10-15
16-19
20-29
30-34
35-42
Test Report
Applicant:
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Number
: TWNC00304282
Date
: Mar 29, 2013
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Ceramic Body
Part Number
: 909-444_909-157_909-438
Date Sample Received
: Mar 21, 2013
Date Test Started
: Mar 22, 2013
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized by:
On Behalf of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
*THJ0304282*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 1 of 7
Number
Test Conducted
: TWNC00304282
(Ⅰ) Test Result Summary:
Test Item
Result
White
ceramic
RL
ND
2
ND
2
ND
2
ND
1
ppm
ND
5
ppm
ND
5
ppm
ND
5
ND
5
ND
5
ND
5
ND
5
ppm
ND
5
ppm
ND
5
ppm
ND
5
Unit
Test Method
Heavy Metal
Cadmium (Cd) Content
ppm
Lead (Pb) Content
ppm
Mercury (Hg) Content
ppm
Chromium VI (Cr6+) Content
ppm
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls
(MonoBB)
Dibrominated Biphenyls
(DiBB)
Tribrominated Biphenyls
(TriBB)
Tetrabrominated Biphenyls
(TetraBB)
Pentabrominated Biphenyls
(PentaBB)
Hexabrominated Biphenyls
(HexaBB)
Heptabrominated Biphenyls
(HeptaBB)
Octabrominated Biphenyls
(OctaBB)
Nonabrominated Biphenyls
(NonaBB)
Decabrominated Biphenyl
(DecaBB)
ppm
ppm
ppm
ppm
With reference to IEC
62321: 2008, by
microwave digestion and
determined by ICP-OES.
With reference to IEC
62321: 2008, by
microwave digestion and
determined by ICP-OES.
With reference to IEC
62321: 2008, by
microwave digestion and
determined by ICP-OES.
With reference to IEC
62321: 2008, by
alkaline digestion and
determined by UV-Vis
Spectrophotometer.
With reference to IEC
62321: 2008, by solvent
extraction and
determined by GC-MS and
further HPLC-DAD
confirmation when
necessary.
*THJ0304282*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 2 of 7
Number
Test Conducted
Test Item
Unit
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers
ppm
(MonoBDE)
Dibrominated Diphenyl Ethers
ppm
(DiBDE)
Tribrominated Diphenyl Ethers
ppm
(TriBDE)
Tetrabrominated Diphenyl
ppm
Ethers (TetraBDE)
Pentabrominated Diphenyl
ppm
Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers
ppm
(HexaBDE)
Heptabrominated Diphenyl
ppm
Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers
ppm
(OctaBDE)
Nonabrominated Diphenyl Ethers
ppm
(NonaBDE)
Decabrominated Diphenyl Ether
ppm
(DecaBDE)
Halogen Content
Fluorine (F)
ppm
Chlorine (Cl)
ppm
Bromine (Br)
ppm
Iodine (I)
ppm
Remarks:
ppm
ND
RL
: TWNC00304282
Test Method
With reference to IEC
62321: 2008, by solvent
extraction and
determined by GC-MS and
further HPLC-DAD
confirmation when
necessary.
With reference to EN
14582:2007 by
calorimetric bomb with
oxygen and determined
by Ion Chromatograph.
Result
White
ceramic
RL
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
ND
ND
ND
50
50
50
50
= parts per million based on weight of tested sample = mg/kg
= Not detected
= Reporting Limit, Quantitation limit of analyte in sample
Responsibility of Chemist:
Date Sample Received
Test Period
Kevin Liu/ Irene Chiou/ Vico Lin
: Mar 21, 2013
: Mar 22, 2013 To Mar 29, 2013
*THJ0304282*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 3 of 7
Number
Test Conducted
(Ⅱ) Limit:
RoHS Limit
Restricted Substances
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
: TWNC00304282
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from Annex II of 2011/65/EU for homogeneous material.
*THJ0304282*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 4 of 7
Number
Test Conducted
: TWNC00304282
(Ⅲ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
PBBs/PBDEs
Weigh sample and
add organic solvent
By Soxhlet
extraction or
Solvent extraction
Concentrate the
extract and make up
with organic
solvent
Cr
6+
Substrate
Cd/Pb/Hg
Weigh sample
and add
alkaline
solution
For different
material, digest
the sample with
*1
appropriate acid
Plating
Cr
6+
By spot test
Definite temp.
extraction
Cool and filter
the extract
Confirm the tested
samples are
totally dissolved
Negative
Get 50cm2 sample
Make up with
deionized water
By boiling water
extraction
Analyzed by ICP-OES
Analyzed by GC-MSD
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
*2
Make up with deionized
water and add
diphenyl-carbazide
solution
Analyzed by UV-VIS
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
*THJ0304282*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 5 of 7
Number
Test Conducted
: TWNC00304282
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
bomb at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions
governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this
report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in
the event of our gross negligence or wilful misconduct.
*THJ0304282*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 6 of 7
Number
Test Conducted
: TWNC00304282
Photo
*THJ0304282*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 7 of 7
Test Report
Applicant:
Number : TWNC00289673
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Dec 13, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Solder
Part Number
: 692481
Date Sample Received
: Dec 06, 2012
Date Test Started
: Dec 07, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
*THJ0289673*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 1 of 6
Number : TWNC00289673
Test Conducted
(Ⅰ) Test Result Summary :
Result (ppm)
Silvery metal
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content (mg/kg with 50cm2)
ND
260
ND
Negative (< 0.02)
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
<
= Less than
mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre
Negative = A negative test result indicated positive observation
was not found at the time of Test.
Responsibility of Chemist : Irene Chiou / Kevin Liu
Date Sample Received
Test Period
: Dec 06, 2012
: Dec 07, 2012 To Dec 12, 2012
(Ⅱ) RoHS Limits:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from Annex II of 2011/65/EU for homogeneous
material.
*THJ0289673*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 2 of 6
Number : TWNC00289673
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples are
totally dissolved and determined by
ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex B, by boiling water
extraction and determined by UV-Vis
Spectrophotometer.
Reporting Limit
2 ppm
2 ppm
2 ppm
0.02
mg/kg with 50cm2
Remark: Reporting limit = Quantitation limit of analyte in sample
*THJ0289673*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 3 of 6
Number : TWNC00289673
Test Conducted
(Ⅳ) Measurement Flowchart:
Test For Cd/Pb/Hg/Chromium (VI)
Reference Standard:IEC 62321 edition 1.0:2008
Sampling/grinding or cutting
Cd/Pb/Hg
Cr
6+
Polymers /
Electronics
Metal
For different
material, digest
the sample with
*1
appropriate acid
By spot test
Negative
Confirm the tested
samples are
totally dissolved
Make up with
deionized water
*2
Weigh sample
and add
alkaline
solution
Get 50cm2 sample
Definite temp.
extraction
Boiling water
extraction
Cool and filter
the extract
Analyzed by ICP-OES
Make up with deionized
water and add diphenylcarbazide solution
Analyzed by UV-VIS
*THJ0289673*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 4 of 6
Number : TWNC00289673
Test Conducted
Remarks:
*1: List of Appropriate Acid:
Material
Acid Added for Digestion
Polymers
HNO3,HCl,HF,H2O2,H3BO3
Metals
HNO3,HCl,HF
Electronics
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined
as detected.
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions
governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this
report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in
the event of our gross negligence or wilful misconduct.
*THJ0289673*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 5 of 6
Number : TWNC00289673
Test Conducted
Photo
*THJ0289673*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 6 of 6
AOV"BPFS,U
TESTREPORT
R02
NO.:4002R12100802+1
Dare:ocr.10,2012
Customer:SuzhouFuHongElectronjc
InduslrialCo.,
Lld.
XIANGCHENG
DlsTRlCT,
SUZHOU,
CHINA
Addres!:NO.89WEIDUROAD,WANGTINGTOWN,
to
be
Reporton ths submitreds.mplesald
S.mplename:CoppeJ,shell
Mod€h/
Item/LoiNo.:/
Metarlal:/,
Buyer: / ,
Suppli€r:/
Samplorecaivsdd.te: Ocl.08.2012
1o'O4r'10,
2012
Testinsperiod:Ffomoct os,20!€
'\l
'
. . ,,
E9S!.s-Ecs!ed9!f
samplein
Chrcmium
contentin thesubmitled
& Hexavalent
As specifiedby dient, to determineihe Lead,cadmlun, Mercury
accordancewith Dircctive2002/95/EC{RoHS).
Ec!!!s-ee$9!.:
instrumeni I\4QL
Measunng
Testingltem
(cd)
Cadmium
(Hg)
[4ercury
IEC62321:2008,s€ction9
|EC62321:
2008,seclionI
7
lEc 623212008,seclron
Chromum(Cr\rl)
IEC623212008AnnexB
Lead(Pb)
ICP€ES
2-'nglkg
ICP-OES
2 mg/kg
tcP-oEs
2 mg/kg
0.02m9/k9'
Ieq
r 0.02mg/kgreE|sto theMQLofsampleextfaction
liquid
SsElcge!:
Decision
ol 18 Aug 2005
of commission
withthe requirements
-whentesledas speci{i€d
samplecomplied
the submitted
2005/618/Ec
noiiliedunderdocument
2002/95/Ec
Directjve
amending
ILS,PLEASEREFERTOTHE FOLLOWNGPAGE(S)***
signedlor andon behalfof
Brcncn
Co.,Ltd,Kunshan
Technology
Shenzhen
AOVTesling
We-r k] n
**n*"oor,
/blfil
caeateaaer:
LiTingting,Maggie
ooo,',*or44.
Ylan Qi, lrickey
Chemic€lTestDirecror
S I t E N 2 H E NA O V T f S I I N G T € C H N O I , O 6 YC O . , I " T O . K U N S N ABNR A N C T I
,
/// \ Noll ne
Ja,t 7tt) 9€'t'o
AOV'*F#S,[
TESTREPORT
NO.:4002R121008024-1
R02
Oate:Od.10,2012
1. To Determiney'.ead,
C€dmium
Contenli(Metalsubslrate)
I*redby (y'a04*
Weighihe sampleinto
Add ihe digestionsolulionithe
vesselis heatedunlilthe sample
AddHrOruntilthe
sampleis clear
nlter;washed
and
Cooling
thevess€|,
Rlled
wat€r.
10themarkwithdistill€d
To Dete
sulit€le)
Content i|retb.r
. \ .
The sampleis digestedin the
Weighihe sample
microwaveovenfollowinga specific
decomposrlonprogram
Tested
by lcP-oES
Coolingthe vessel,tiltei washedand
filledlothe maiKwilh dislilledwater.
ChromiumContenl(boiling-wat€F€xtlaclion):([4etalEubstrate)
Takethe (50i5) cm,
samplein the beaker.
Heat50 mLof Olwaterin
thebe6ker
to boilingfor 1o
F;;1.-
lhe sample,
andcool
Remove
thebeak€rto roomtemperature,
anddo thecolorreaction
Testthe samplesolutionand lhe 0.02
ng/kg standardsolltion by uv-vls.
BSANCH
lCCINOLOGYCO.,LTD.KUNSIIAN
SH€NZH€NAOVTESTITIG
(:
Hotlrne
'tL)0700 8600
nov'Bpf,F,il
TESTREPORT
NO.:
4002R121008024-1R02
Daie:Ocl.10,
2012
5. TooetemineHexavalenl
Chromium
Contonlin colorlessand coloredchromatecoatingon metats:iPtating)
_
.. -i\
: va'hu't'
lfthe lest resultis positive,
the sample is consideredto
havehexavalent
chmmium
Place
1-5
Boiling- water- extraotion
procedu€shallbe usedto
and the 0.02 mg/kg
lflhee is interference
or it is hardto decide
whetherlhesamplehavelhe hexavalent
5.2Boiling-wateF
enradion
Remove
thesample,
andcool
thebeaker
lo roomtemperalure,
anddolhe colorreaction
Heat50 mlof Dlwaier in the
samplein thebeaker.
beakerto boilingfor 10 min
Testtnesamplesolution
andlhe0.02
mg/kgstandadsolulion
by UV-VIS.
SampleDelcriptlon:
Code
1-1
SampleDescndion
Substrate
Plating
Te3tR63ulb:
Unit
RoHSLimit
Lead(Pb)
msfts
1000
N.D.
10
(Cd)
Cadmium
Merorry(Hg)
mg/K9
N.D.
ms/Kg
100
1000
N.D,
N.O.
N.D.
Chromium
{Crl,ll)
m9/kg
1000
Negative
Negative
s8€NZh€N AOVT€SrtNGTECHNOlOSYCO,,tTD,TUNSHAI!
ARANCH
,.r
Ho t l i ne
.100700B6a0
nov'F"Ff"qn
TESTREPORT
No.:A002R1210o602:L1
R02
-ThenewRoHSdircclive
2011/6tEU,on Jul.21,2011comeintoforc€,onJan.03,2013lheformalimplementation,
Direclive
repealed
2002r'95/EC
simultaneously.
ahallbe
Sp€cimens,
whichr€Slested
lo detemineLead,Cadmium
havebeendissolved
andMercury
Content,
completely,
-mg/kg=ppm ,
-N.D.=not
i",,,,,,
( The iested sample
resultis uncertain
or
neoatve.,
-"The te8t is bas€d on lhe followins d!!{mplifi:
maybe cannot stand lor the physical lrdh 6t s€r
Coppershell
SH€NZII
AFANCH
AOVTIST|n|GTECHNOIOCVCO.,ITD.KUNSHAN
Ho t l i ne
400 /00 8600
Test Report
Applicant:
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Number
: TWNC00304280
Date
: Mar 29, 2013
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Black Ink
Part Number
: 425672
Date Sample Received
: Mar 21, 2013
Date Test Started
: Mar 22, 2013
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized by:
On Behalf of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 1 of 10
Number
: TWNC00304280
Test Conducted
(Ⅰ) Test Result Summary:
Test Item
Result
Submitted
samples
RL
ND
2
ND
2
ND
2
ND
1
ppm
ND
5
ppm
ND
5
ppm
ND
5
ND
5
ND
5
ND
5
ND
5
ppm
ND
5
ppm
ND
5
ppm
ND
5
Unit
Test Method
Heavy Metal
Cadmium (Cd) Content
ppm
Lead (Pb) Content
ppm
Mercury (Hg) Content
ppm
Chromium VI (Cr6+) Content
ppm
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls
(MonoBB)
Dibrominated Biphenyls
(DiBB)
Tribrominated Biphenyls
(TriBB)
Tetrabrominated Biphenyls
(TetraBB)
Pentabrominated Biphenyls
(PentaBB)
Hexabrominated Biphenyls
(HexaBB)
Heptabrominated Biphenyls
(HeptaBB)
Octabrominated Biphenyls
(OctaBB)
Nonabrominated Biphenyls
(NonaBB)
Decabrominated Biphenyl
(DecaBB)
ppm
ppm
ppm
ppm
With reference to IEC
62321: 2008, by
microwave digestion and
determined by ICP-OES.
With reference to IEC
62321: 2008, by
microwave digestion and
determined by ICP-OES.
With reference to IEC
62321: 2008, by
microwave digestion and
determined by ICP-OES.
With reference to IEC
62321: 2008, by
alkaline digestion and
determined by UV-Vis
Spectrophotometer.
With reference to IEC
62321: 2008, by solvent
extraction and
determined by GC-MS and
further HPLC-DAD
confirmation when
necessary.
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 2 of 10
Number
: TWNC00304280
Test Conducted
Test Item
Unit
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers
ppm
(MonoBDE)
Dibrominated Diphenyl Ethers
ppm
(DiBDE)
Tribrominated Diphenyl Ethers
ppm
(TriBDE)
Tetrabrominated Diphenyl
ppm
Ethers (TetraBDE)
Pentabrominated Diphenyl
ppm
Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers
ppm
(HexaBDE)
Heptabrominated Diphenyl
ppm
Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers
ppm
(OctaBDE)
Nonabrominated Diphenyl Ethers
ppm
(NonaBDE)
Decabrominated Diphenyl Ether
ppm
(DecaBDE)
Phthalates
Di(2-ethylhexyl) Phthalate
ppm
(DEHP)
Dibutyl Phthalate (DBP)
ppm
Benzyl Butyl Phthalate (BBP)
ppm
Halogen Content
Fluorine (F)
ppm
Chlorine (Cl)
ppm
Bromine (Br)
ppm
Iodine (I)
ppm
Others
Hexabromo cyclododecane
(HBCDD)
ppm
Test Method
With reference to IEC
62321: 2008, by solvent
extraction and
determined by GC-MS and
further HPLC-DAD
confirmation when
necessary.
Result
Submitted
samples
RL
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
ND
5
With reference to EN
14372: 2004, by solvent
extraction and
determined by GC-MS.
ND
50
ND
ND
50
50
With reference to EN
14582:2007 by
calorimetric bomb with
oxygen and determined
by Ion Chromatograph.
ND
ND
ND
ND
50
50
50
50
With reference to USEPA
3540C, by solvent
extraction and
determined by GC-MS.
ND
10
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 3 of 10
Number
: TWNC00304280
Test Conducted
Remarks:
ppm
ND
RL
= parts per million based on wet weight of tested sample = mg/kg
= Not detected
= Reporting Limit, Quantitation limit of analyte in sample
Responsibility of Chemist:
Date Sample Received
Test Period
Kevin Liu/ Irene Chiou/ Vico Lin
: Mar 21,2013
: Mar 22,2013 to Mar 26,2013
(Ⅱ) Limit:
RoHS Limit
Restricted Substances
Limits
Cadmium (Cd) content
0.01% (100ppm)
Lead (Pb) content
0.1% (1000ppm)
Mercury (Hg) content
0.1% (1000ppm)
Chromium VI (Cr6+) content
0.1% (1000ppm)
Polybrominated Biphenyls (PBBs)
0.1% (1000ppm)
Polybrominated Diphenyl Ehters (PBDEs)
0.1% (1000ppm)
The above limits were quoted from Annex II of 2011/65/EU for homogeneous material.
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 4 of 10
Number
: TWNC00304280
Test Conducted
(Ⅲ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
PBBs/PBDEs
Weigh sample and
add organic solvent
By Soxhlet
extraction or
Solvent extraction
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Cr
6+
Substrate
Cd/Pb/Hg
Weigh sample
and add
alkaline
solution
For different
material, digest
the sample with
*1
appropriate acid
Plating
Cr
6+
By spot test
Definite temp.
extraction
Cool and filter
the extract
Confirm the tested
samples are
totally dissolved
Negative
*2
Get 50cm2 sample
Make up with
deionized water
By boiling water
extraction
Analyzed by ICP-OES
Make up with deionized
water and add
diphenyl-carbazide
solution
Analyzed by UV-VIS
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 5 of 10
Number
: TWNC00304280
Test Conducted
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 6 of 10
Number
: TWNC00304280
Test Conducted
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
bomb at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 7 of 10
Number
: TWNC00304280
Test Conducted
Test For Phthalates Contents
Reference Method: EN 14372: 2004
Sampling/grinding or
cutting
Weigh sample and add
organic solvent
By solvent extraction
Concentrate the extract
and make up with
organic solvent
Analyzed by GC-MSD
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 8 of 10
Number
: TWNC00304280
Test Conducted
Test For Hexabromocyclododecane (HBCDD)
Reference Standard:USEPA 3540C
Sampling/grinding or cutting
Weigh sample and add organic
solvent
By soxhlet extraction
Concentrate the extract and
make up with organic solvent
Analyzed by GC-MSD
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions
governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this
report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in
the event of our gross negligence or wilful misconduct.
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 9 of 10
Number
: TWNC00304280
Test Conducted
Photo
*THJ0304280*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C.
全國公證檢驗股份有限公司
11492 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 10 of 10
Test Report
Applicant:
Number:
ELSCHUKOM ELEKTROSCHUTZKOMPONENTENBAU
GMBH
GEWERBESTRASSE 87,D-98669 VEILSDORF,
GERMANY
Date:
SHAH0036227401
JAN 18, 2013
Sample Description:
Two(2) pieces of submitted samples said to be :
(1) Mixed all kinds of metal substrates.
(2) Mixed all kinds of plating layers.
Item Name
: Silver Plated & Pure Silver Wires.
Item No.
: (B-1) 101.014 -. ---– silver plated copper wire – Cu, Ag--%
(B-2) 101.0131.---– pure silver wire – Ag 1000
(B-3) 101.0123.0--– silver plated purest nickel wire – Ni99.98%, Ag1%
(B-4) 101.0182.0--– silver-copper alloy plated copper plated iron nickel alloy wire
– ElconD, AgCu5%
(B-5) 101.0120.0--– silver plated constantan wire – CuNi44, Ag5%
(B-6) 101.0151.0--– silver plated copper - nickel 44 alloy wire
– CuNi44, Ag10%
(B-7) 1050--31.-------– pure silver strips – Ag 1000 pure
Country Of Origin
: Germany.
************************************************************************************************************************************************************
Tests Conducted:
As requested by the applicant, for details refer to attached page(s).
************************************************************************************************************************************************************
To Be Continued
Authorized by:
For intertek testing services Ltd., Shanghai
Jacob Lin
General Manager
Page 1 Of 5
Intertek Testing Services Ltd., Shanghai
Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233
上海天祥質量技術服務有限公司
上海市宜山路 801 號金陵商務廣場 B 座 200233
Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740
www.intertek.com www.intertek.com.cn
Test Report
Number:
SHAH0036227401
Tests Conducted
(A) Test result of RoHS Directive:
Result
Testing item
(1)
Cadmium (Cd) content (mg/kg)
ND
Lead (Pb) content (mg/kg)
ND
Mercury (Hg) content (mg/kg)
6+
Chromium2(VI)(Cr ) result (by boiling water extraction on metal) (mg/kg
with 50cm )
ND
ND
Result
Testing item
(2)
Cadmium (Cd) content (mg/kg) /Plating
ND
Lead (Pb) content (mg/kg) /Plating
ND
Mercury (Hg) content (mg/kg) /Plating
ND
6+
Chromium2(VI)(Cr ) result (by boiling water extraction on metal) (mg/kg
with 50cm ) /Plating
ND
2
Remark:mg/kg with 50cm = milligram per kilogram with 50 square centimeter
ND = not detected
(B) RoHS Requirement:
Restricted substances
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
6+
Chromium (VI) (Cr )
Limits
0.01% (100 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
0.1% (1000 mg/kg)
The above limits were quoted from RoHS Directive 2011/65/EU for homogeneous material.
(C) Test method:
Testing item
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
6+
Chromium (VI) (Cr ) content (for
metal)
Testing method
With reference to IEC 62321 Edition 1.0: 2008, by acid
digestion until the tested sample was totally dissolved, and
determined by ICP-OES.
With reference to IEC 62321 Edition 1.0: 2008, by acid
digestion until the tested sample was totally dissolved, and
determined by ICP-OES.
With reference to IEC 62321 Edition 1.0: 2008, by acid
digestion until the tested sample was totally dissolved, and
determined by ICP-OES.
With reference to IEC 62321 Edition 1.0: 2008, by boiling
water extraction and determined by UV-VIS
Spectrophotometer.
Reporting limit
2 mg/kg
2 mg/kg
2 mg/kg
2
0.02mg/kg with 50cm
(in testing solution)
Date sample received: Jan.14, 2013
Testing period: Jan.14, 2013 To Jan.17, 2013
************************************************************************************************************************************************************
To Be Continued
Page 2 Of 5
Intertek Testing Services Ltd., Shanghai
Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233
上海天祥質量技術服務有限公司
上海市宜山路 801 號金陵商務廣場 B 座 200233
Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740
www.intertek.com www.intertek.com.cn
Test Report
Number:
SHAH0036227401
Tests Conducted
(D) Measurement flowchart:
Test for Cd/Pb/Hg/Cr (VI)/PBBs/PBDEs contents
Reference standard: IEC 62321 Edition 1.0: 2008
Sampling/grinding or cutting
Cr
Cd/Pb/Hg
Metal
Weigh sample and for
different material, digest
the sample with
*1
appropriate acid
Positive
No
Confirm the tested
samples are totally
dissolved
Yes
Polymers /
electronics
PBBs/PBDEs
Weigh sample
and add alkaline
solution
Spot test
Get 50cm
samples
6+
Weigh sample and
add organic
solvent
*2
Definite temp.
Extraction
2
Boiling water
extraction
Soxhlet extraction
or
Solvent extraction
Cool and filter the
extract
Concentrate the
extract and make
up with organic
solvent
Make up with
deionized water
Analyzed by ICP-OES
Make up with deionized water
and add diphenyl-carbazide
solution
Analyzed by GC-MSD
Analyzed by UV-VIS
Remarks:
*1: list of appropriate acid:
Material
Polymers
Metals
Electronics
Acid added for digestion
HNO3,HCL,HF,H2O2,H3BO3
HNO3,HCL,HF
HNO3,HCL,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
************************************************************************************************************************************************************
To Be Continued
Page 3 Of 5
Intertek Testing Services Ltd., Shanghai
Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233
上海天祥質量技術服務有限公司
上海市宜山路 801 號金陵商務廣場 B 座 200233
Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740
www.intertek.com www.intertek.com.cn
Test Report
Number:
SHAH0036227401
Tests Conducted
************************************************************************************************************************************************************
To Be Continued
Page 4 Of 5
Intertek Testing Services Ltd., Shanghai
Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233
上海天祥質量技術服務有限公司
上海市宜山路 801 號金陵商務廣場 B 座 200233
Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740
www.intertek.com www.intertek.com.cn
Test Report
Number:
SHAH0036227401
Tests Conducted
************************************************************************************************************************************************************
End Of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular
course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability
to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or
representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a
diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise,
except in the event of our gross negligence or wilful misconduct.
Page 5 Of 5
Intertek Testing Services Ltd., Shanghai
Block B, Jinling Business Square, No.801 YiShan Road, Shanghai, China. 200233
上海天祥質量技術服務有限公司
上海市宜山路 801 號金陵商務廣場 B 座 200233
Telephone: +86 21 6120 6060 Facsimile: +86 21 6127 9740
www.intertek.com www.intertek.com.cn
Test Report
Applicant:
Number : TWNC00285761
Littelfuse Philippines Inc.
LIMA Technology Center, Lipa City,
Malvar, Batangas
Date
: Nov 19, 2012
Sample Description:
One (1) group of submitted samples said to be :
Part Description
: Yarn
Part Number
: 648112-001
Date Sample Received
: Nov 12, 2012
Date Test Started
: Nov 13, 2012
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Authorized By:
On Behalf Of Intertek Testing Services
Taiwan Limited
K. Y. Liang
Director
*THJ0285761*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 1 of 8
Number : TWNC00285761
Test Conducted
(Ⅰ) Test Result Summary :
Result (ppm)
Submitted Samples
Test Item
Heavy Metal
Cadmium (Cd) content
Lead (Pb) content
Mercury (Hg) content
Chromium VI (Cr6+) content
Polybrominated Biphenyls (PBBs)
Monobrominated Biphenyls (MonoBB)
Dibrominated Biphenyls (DiBB)
Tribrominated Biphenyls (TriBB)
Tetrabrominated Biphenyls (TetraBB)
Pentabrominated Biphenyls (PentaBB)
Hexabrominated Biphenyls (HexaBB)
Heptabrominated Biphenyls (HeptaBB)
Octabrominated Biphenyls (OctaBB)
Nonabrominated Biphenyls (NonaBB)
Decabrominated Biphenyl (DecaBB)
Polybrominated Diphenyl Ethers (PBDEs)
Monobrominated Diphenyl Ethers (MonoBDE)
Dibrominated Diphenyl Ethers (DiBDE)
Tribrominated Diphenyl Ethers (TriBDE)
Tetrabrominated Diphenyl Ethers (TetraBDE)
Pentabrominated Diphenyl Ethers (PentaBDE)
Hexabrominated Diphenyl Ethers (HexaBDE)
Heptabrominated Diphenyl Ethers (HeptaBDE)
Octabrominated Diphenyl Ethers (OctaBDE)
Nonabrominated Diphenyl Ethers (NonaBDE)
Decabrominated Diphenyl Ether (DecaBDE)
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
*THJ0285761*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 2 of 8
Number : TWNC00285761
Test Conducted
(Ⅰ) Test Result Summary :
Result (ppm)
Submitted Samples
Test Item
Halogen Content
Fluorine (F)
Chlorine (Cl)
Bromine (Br)
Iodine (I)
ND
ND
ND
ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg
ND = Not detected
Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received
Test Period
: Nov 12, 2012
: Nov 13, 2012 To Nov 15, 2012
(Ⅱ) RoHS Limits:
Restricted Substances
Cadmium (Cd) Content
Lead (Pb) Content
Mercury (Hg) Content
Chromium VI (Cr6+) Content
Polybrominated Biphenyls (PBBs)
Polybrominated Diphenyl Ehters (PBDEs)
Limits
0.01% (100ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
0.1% (1000ppm)
The above limits were quoted from Annex II of 2011/65/EU for homogeneous
material.
*THJ0285761*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 3 of 8
Number : TWNC00285761
Test Conducted
(Ⅲ) Test Method:
Test Item
Cadmium (Cd)
content
Lead (Pb) content
Mercury (Hg)
content
Chromium VI (Cr6+)
content
Polybrominated
Biphenyls (PBBs)
Polybrominated
Diphenyl Ethers
(PBDEs)
Halogen Content
Test Method
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 8/9/10, by
microwave digestion until the tested
samples are totally dissolved and
determined by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in clause 7, by microwave
digestion until the tested samples
are totally dissolved and determined
by ICP-OES.
With reference to IEC 62321 edition
1.0:2008 in annex C, by alkaline
digestion and determined by UV-Vis
spectrophotometer.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MS
and further HPLC-DAD confirmation
when necessary.
With reference to IEC 62321 edition
1.0:2008 in annex A, by solvent
extraction and determined by GC-MS
and further HPLC-DAD confirmation
when necessary.
With reference to EN 14582:2007 by
calorimetric bomb with oxygen and
determined by Ion Chromatograph.
Reporting Limit
2 ppm
2 ppm
2 ppm
1 ppm
5 ppm
5 ppm
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
*THJ0285761*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 4 of 8
Number : TWNC00285761
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents
Reference Standard: IEC 62321 edition 1.0:2008
Sample preparation
For non-metal part
For metal part
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
PBBs/PBDEs
Weigh sample and
add organic solvent
By Soxhlet
extraction or
Solvent extraction
Concentrate the
extract and make up
with organic
solvent
Analyzed by GC-MSD
Cr
6+
Substrate
Cd/Pb/Hg
Weigh sample
and add
alkaline
solution
For different
material, digest
the sample with
*1
appropriate acid
Plating
Cr
6+
By spot test
Definite temp.
extraction
Cool and filter
the extract
Confirm the tested
samples are
totally dissolved
Negative
*2
Get 50cm2 sample
Make up with
deionized water
By boiling water
extraction
Analyzed by ICP-OES
Make up with deionized
water and add
diphenyl-carbazide
solution
Analyzed by UV-VIS
*THJ0285761*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 5 of 8
Number : TWNC00285761
Test Conducted
(Ⅳ) Measurement Flowchart:
Remarks:
*1: List of Appropriate Acid:
Material
Polymers
Metals
Electronics
Acid Added for Digestion
HNO3,HCl,HF,H2O2,H3BO3
HNO3,HCl,HF
HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
*THJ0285761*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 6 of 8
Number : TWNC00285761
Test Conducted
(Ⅳ) Measurement Flowchart:
Test for Halogen Content
Reference Standard:EN 14582
Sampling/grinding or
cutting
Add absorbent in a
combustion flask &
place weighed sample in
equipment
Fill oxygen into
calorimetric bomb
Ignite then leave the
bomb at room
temperature
Transfer the absorbent
into a volumetric flask
Make up with deionized
water
Analyzed by ion
chromatography
End of Report
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions
governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this
report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not
accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in
the event of our gross negligence or wilful misconduct.
*THJ0285761*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 7 of 8
Number : TWNC00285761
Test Conducted
Photo
*THJ0285761*
Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.
全國公證檢驗股份有限公司
114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410
Page 8 of 8