ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: SMBJ, P6SMB, SACB, 3T, 1KSMB Series Product #: TVS Diode Issue Date: August 13, 2010 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the SMBJ, P6SMB, SACB, 3T, 1KSMB RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks:RoHS Exemptions 5 and 7a apply to these products. Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 7 8 9 Raw Material Part Number NA NA NA NA NA NA NA NA NA Raw Material Description Chip Silicon Wafer Wafer Passivation Lead Frame Matrix Lead Frame Solder Paster Epoxy Molding Compound Tin Plating Clip 2 Page(s) 3-9 10-16 17-23 24-28 29-33 34-40 41-47 48-54 55-59 TEgT RBPORT APPLICANT: NUMBdR: CONCORDSBMICONDUCTOR (wrxr ) CO., LTD. EAST 1,*, ZHENFA 5 ROAD, SHUO FANG INDUSTRIAL PARK WUXI NATIONAL HIGHTECH DEVELOPMEIVI ZONE, WUXI,.JIANGSU, CHINA ATTN; ZI]ANG XIAOPENG SAMPLE DESCRIPTION: ONE(1)PIECE OF SI]BMITTED ITEM NAI.,IE : IBNDOR : COMPONEM OR PART NO. : TEST ITEM : wrJxHoao02722 DATE: AUG 06, 2010 SAMP'IE SAID TO BE :CHIP. CI]IP. IJITTELFUSE CONCORD. SILICON+NICKEL+GLASS. Pb, Cd,Hg, CrVI, PBB PBDE,F,C1,Br,r. TESTS CO$DUCTED: AS REQUESTED BY THE APPLICA}II, FOR DETAILS REFER TO ATTACI.IED PAGE(S) TO BE CONTINUED PREPARED AND CHECKED BY: FOR INTERTEK TESTING SERVICES WI'XI IJTD 'fESSICA ],U GENERAL MANAGER PAGE 1 OF ? IntertekTestingServlcesWuxl Ltd. No.3 Fube Re4 Xsha. E@iomic Oddopm.nl Z.no Wui 214101,Ji.rg$, China T6l +36 510 3s21 4567 Fs €a 510 332U0123 E-ftit: 6i5umEo.de.*un@idenek @m TEST REPORT NUMBER: WIIxHo0002 722 TESTS CONDUCTED (A) TEST RESULT SUM}4ARY: TESTTNG TTB!f CADMIUM (cd) CONTENT (mg^qr) LEAp (pb) coNrENr RESU],7 ND 53180 ND ND (mg,/kg) MERCURY (Hq) CONIENT (no/ko ) (cr- ) COMIENT (mg/kg) tv!l (FOR NON-METAL) gU!TbRUMINA.IED BIPHENYLS (PBBg) (mq/k MONOBROMO eIpHeNyr,S (VonoSB) 1,'.Tt'r(UMU BI PIiENYLS r) ND ND ND (DiBB) TRIBROMOBIPHENYLS (TriBB) TETRABRoMo BTPHENYIJS (TetTaBB ) PEMIAEROMO BIPHENYLS { PENEABB) HEXABROMO BIPHENYLS (HexaBBHEPTABROMO BIPHENYLS (HeptaBB ) OCTABROMOBIPHENYLS (ocIaBB) NONABROMOBIPHENYLS (NonaBB) DECABROMOBIPHENYI, (DecaBB) POLYBROMINATED DIPHE}.IYL ETHERS ( PBDES MONOBROMODIPHENY], ETHERS (MonoBDE) DIBROMO DIPHEITTL ETHERS (DiBDE ) TRIBROMO DTPHENYL ETHERS {'rrriBDE ) TETRABROMO DIPHENYL ETHERS (Tet!aBDE) PENTABROI.{ODIPHENfII ETHERS (PentaBDE ) HEXABROMODIPHENYL ETHERS (HexaBDE ) HEPTABROMO DIPHENYL ETHERS lHeptaBDE) OCTA3ROMO DIpHENfL ETHERS (OctaBDE) NONABROMODIPHENYL ETHERS (NonaBDE) DECABROMODIPHENYIT ETHER (DecaBDE) REMARK: ND ND ND ND ND ND ND {mq/kq ) ND ND ND ND ND ND ND ND ND ND mg/kg = 1411,116pay pER KTLoGRAMBASED oN DRy wErcHT= DDm ND = NOT DETBCTED # = THE RESULT IS FOR REFERENCEONLY TO BE CONTINUED PAGE 2 OF 7 Intetek Testing Se.vicesWuxi Ltd. No.3Fub€iRoad,XshdnE@ndtc o.v€brn€.t zorc, Wui 21,t101, Ji6n€s,Chin. Fa* +36s10Sa200,{23 E-m.ri 4sunslsoodivu @inrd6k.6n TEST REPORT NUMBERI WI]XHOO OO2722 TESTS COM)UCT'ED (B)RoHS REQUIREMENT: RESTRTCTBD SI]BSTANCES CADMIW (Cd) (100 mg/kq) 0.01t ],EAD ( Pb) 0 . 19 ( 10 oO mqlkqJ MERCURY (Hg) (1000 mg/ikq) 0.19 CHROMIUM(vI ) (Cr6t POLYBROMINATED BI PHENYiS_IPBE; ) 0.1* (1000 mg/ksj ( 1 o o om s / 94t PglYPRoMrNArEp prP (1000 mg/kq) 0.1t THE ABOVE LIMTTS WERE OUOTED FP'ot4 20o2/95/Ec 2 0 0 5 / 5 1 8 / E C F O R HOMOGENEOUS MATERIAL. ano aver.mrqEF.r (C) TEST METHOD: TESTTNG ItE CADMII'M (Cd) CONTEMI LESTXNG METEOD rffd Krl!$r(ENus Io IEc 52321 EDITION 1.0: 2OOe, By ACID DIGESTION AND DETERMINED BY ]CP- REPORTII{G r,rxr? 2 ng/kg oEs wrrt1 LEAD (Pb) CONTENT r(!i!-!jt(liN(jE To IEc 52321 EDITION 1.0: 2008, By AcrD DIGESTION AND DETERMINEDBY ICP- mg/ks MERCURY(Hs) CONIENT WITH REFERENCET- IEC 62321EDTTION 1.0: 2008, BY ACID DIGESTION AND DETERMTNED BY ICP- mg/ks CI{ROMIUM (VI) (cr6+) CoNTEITTI (FOR NON-MEI]AI,) WITH REFERENCETA IEC 62321EDITION 1.0: 2008, By AIKALINE DIGESTION AND DETBR.},IINEDBY UVVIS SPECTROPHOTOMETER oEs oEs POLYBROMINATED WITH REFERENCETO TBC TEC 62321 BIPHENYLS (PBBS) & E D I T I O N 1 , 0 : 2 0 0 8 , B y S O L V E N T POIJYBROMINATED EXTRACTION AND DETERMINED BY DIPHENYL ETHERS GCIMS AND FURTHER HPLC ( PBDEs) CONFIR}IATION WHEN NECESSARY. DATE SAMPLE RECEIVED:AUG 02, 2OaO TESTING PBRIOD:AUG 02, 2O1O TO AUG 05, r.r.g/ks s mg/ks 2O1O TO BE COI\]"TINUBD Intert k Testing Se.vlcesWuxi Ltd. \o.3 EubaRo.d.X3h.n Eonw.c Oorebpn€ntZor. wdi 2llt101.Jranos.ch,m l.r +365r08sr1.s67 Fd +365t0$mo42s E @'| @n*ft.rodsw"!@,,,t.16r.@n PAGE 3 OF 7 IEST REPORT NIIMBER : WLIXHo0002?22 TESTS CONDUCTED (D) MEASUREMENT FLOWCHART: TesT FOR Cd/ pb /Hg / CT (Vr) /pBBs/pBDEs CONTENTS REFERENCE STANDARD:tEC 62321 EDITION 1.Or 2O0g SAUPIINC/GRINDIIIC OR CMTINC I -*--.;*r ExrFAc.froN COIIFIRI{ Tr{E TESTED SA]!IP'!ES ARE ToTAJ!I,Y V I I I oR I soLvENr I sxrRAcrroN I -------r----V t**"**,"*;l Exrracr AlrD I I MAKE OP WITS DIIONIZS IIATEi AND ADD DIPHBIIY!CAIAAZID! SOI,UTION I uix! uP $rrH I oRGANrc sorvNr I------f-----I V INORGA].IIC (ANN LUOIFRED WANG/AI,I,Y WAN) oRGANTC (,tENNy XUICHERRY SUN) REI,IARKS : *1: LIST OF APPROPRIATE ACID. CHEMIST: MATERIAL POLYMERS !1ETA],S ELECTRONICS ACID A.DDED FOR DIGESTION HNO3,HCI, HF, H2O' H3EO3 HNO3.HC1,HF HNO3,HCl , H'O',HBF4 *2: IF THE RESULTOF SPOT TEST IS POSITM. BE DETBRMINEDAS DETECTED. CHROMIIIM VI WOULD TO BE CONTINUED PAGE 4 OF ? IntertokT*tlng ServicesWuxiLtd. No.3Fub.i R@d XshanE@nomic Oddorm.nl Zorc wui 214101, Jianls. Chin. Tel +36s10s4214s67 Fa::+3651034200.123E-maild3um6lqood3.ed@int€rt6k.6m TEST REPORT NUIyIBER: WUXHo00 02 722 TESTS CONDUCTED ( I ) TEST RESULT SI,MMARY }IA],OGEN CONTENT : TESTING TTEM vKfrrE lt, BROMII{E (Br) CoNTENT fvufN!, uuNlljN.I (_Ll RESTLT uuNlljN1 (ppm) ND ND ND ND REMARKS : ppm = PARTS pER MTTTLION = mg/kg = NOT DETECTED ND DATE SAMPLE RECEITE: AUG 02, 2010 TEST PERIOD: AUG 02, 2O1O TO AUC 05, 2O1O II ) TEsr METHoD : TESTING ITEM HAI,OGEN (F. CI, CONTENT REITIARKS : Br,I) REPORTING LIMIT TESTING METHOD WITH REFERENCETO IEC 611892.20A6 BY COMBUSTIONFLASK AND DETERMINED BY ION CHROMATOGRAPHY = OUANTITATTON LIMIT REPORTING ],IMIT 50 ppm OF ANALYTE IN SAMPLE TO BE CONTINUED PAGE 5 0 F 7 IntedekTestingServicesWuxiLtd. No3 Fub€i Ro.d Xishan E@noic D.v.lop.ned Zo.e, Wuxi214101,J.ng6u, China Fd: +36 510 Aa200423 E mait 6sum.l9oo&.wu(Dirn€d6k@n TBST REPORT NUMBER: WUXHoOOO2?22 TESTS CONDUCTED (III) MEASnREMENT FLowcHART : TEST FOR HALOGEN CONT'ENT REFERENCEMETHOD: IEC 61f 89_2 TEST 2C12 SAMPLING/GRINDING OR CIITTING A.DD ABSORBT]NT IN A COMBUSTION FI.ASK & PI,ACE WEIGHED SAMPLE IN FILIJ THE COMBUSTION FI.ASK WITH OXYGEN IGNITE THEN LE.AVE THE FIIASK A? ROOM TEMPERATURE ANY TEST SPECIMEN IN ?HE COMBUSTION FLAS(? TRANSF'ER Tl{E ABSORBANT INTO A VOIIU}IETR I C FI.ASK CHEMIST: FRED WANG/ ALLY_ffi TO BE COITIIINUED PAGE 6 OF 7 lntertekTe3tlngServicesWuxiLtd. No s Fubd Red Xsh€n E@nomic D€v.ropn€ Zon6 wln214101, Jiaio&. China T.rr+365108621.557 Fd: +35 510 33200.123 E-m.U:ffiumoEo.dgsd@ d.n k@m TEST REPORT NUMBER: WLIXHo 00 02 722 TESTS CONDUCTED END OF REPORT PAGE ? OF 7 Int€rtakTesting ServicesWuxi Ltd. No.3Fub(j Road,Xish.nEonmic D.v€lopfr.nl Zoie, wqi214101J.n$u, Chnr Tel:+365r0 3A214567 Far +365103S200423 E-m€[email protected] TBST REPORT APPL]CANT: NUMBERI WI]xHo 0 002 719 CONCORD SEMICONDUCTOR(WUXI ) CO., LTD. EAST 1#,ZHENFA 6 ROAD? SI{UO FANG INDUSTRIAI PARK WIIXI NATTONAL HIGHTECH DEVELOPMETII ZONE, WIlxI,.]IANGSU, CHINA ATTN: ZIIANG XIAOPENG DATEI AUG 06, 2010 SAMPLE DESCRIPTION: ONE(1)PIECE OF SUBMITTED SAMPLB SAID TO BE ;SILVBR cnEY METAL. ITEM NAME : SILICON WAFER WITH NICKEL PI,ATING. VENDOR : CONCORD. COMPONENTOR PART NO. SI IJICON+NI CKEL . TAST ITEM P b , C d , H g , C r V I , P B B P B D E ,F , C 1 , B r , I . TESTS CONDUCTED: AS REOUESTED BY THE APPI,ICANT, SUMMARY: TESTED SA!@IrE SUBMITTED SAMPI,E FOR DETAILS REFER TO ATTACHED PAGE (S) STAITDA.RD WITH REFERENCE TO TEST METHOD OF IEC 62324 EDITION 1.0: 2008 AND MAXIMUM CONCENTRATION LIMITS QUOTED FROM RoHS DIRECTIVBS 2OA2 / 95 /EC AND AMEI{DMENT 20Os/61A/EC RESI'I.T PASS TO BE CONTfNUED PREPAREDAND CHECKEDBY: FOR INTERTEK TESTING SERVICES WUXI LTD. JESSICA LU GENERAL MANAGER PAGE 1 0 F ? Iniertek T*tlng ServicesWuxi Ltd. No.sFub.l [email protected] E@nomic O.tdsm.nl Zoi6. Wun21,(101, Ji.ng&,Chin€ T.l: +36s1034214567 Fa* +365rO33200423 E-n.il 6.un.40od..vd @ini€rr.k.@m TEST REPORT NUMBER: WIIXHo00 02719 TESTS CONDUCTED (A) TEST RESUI,T SUMMARY; TESTING tTE!{ tADMIITM (cd) CONIENT (mg/kg) LEAD (Pb) COVIENT (rnqlkq) MERcttRy (Hg) COMTENT (ng/kg) (Vr1 1gt"r) CHROMIIM (BY nesulT BOILING WA?ER EXTRACTION ON METAL) (mq/kq WITH 5 Ocm') PO'JYBROMINATED BIPHENYLS (PBBS) MONOBROMOBIPHENYLS (MonoBB) DIBROMO BIPHENYLS (DiBB) TRIBRO}'4O BIPHENYI,S (TriBB) TETRABROMO BI PHENYLS {TetTaBB) PEI\IAABROMOBIPHENY],S (PenTaBB) HEXABROMOBIPHEI.TYLS (HexaBB) HEPTABROMOBIPHENYLS (HCPIABB) OCTABROMOBIPHENYI,S (ocIaBB) NONABROMOBIPHE}.IYLS (NonaBB) DECABROMOBIPHENYL (DECABB) RESI'',? ND ND ND ND (rng/kg) ND ND ND ND ND ND ND ND ND ND POI,YBROMINATED DIPHENY], ETHERS (PBDES (mq/kq ) MONOBROMODIPHENYL BTHERS (MonoBDE) ND DIBROMO DIPHENYL ETHERS (DiBDE) ND TRIBROMO DIPHENYL ETHERS (TTiBDE ) ND TETRABROMO DIPHENYL ETHERS ND {TetraBDE) PENTABROMODIPHENYT ETHERS ND ( PentaBDE) HBXABROMO DIPHENyL ETHERS (HexaBDE) ND HEPTABROMO DIPHENYTJ ETHERS ND (HeptaBDE ) OCTABROMODIPHENYL ETHERS (OctaBDE) ND NONABROMODIPHENYL ETHERS (NonaBDE) ND DECABROMODIPHENY], ETHER (DecaBDE) ND REMARK: mg/kg = Mrr,LrcRAr{ pER KILoGRAM BASED oN DRy wErcHT= ppm ND = NOT DETECTED pER KTLoGRAM mg/kg wrrH 5ocn' = MTLLTGRAM wrrH 50 SOUARE CENTIMETER TO BE COIIIINUED PAGE 2 OF ? InlertekT€stlngServlcesWuxlLtd. No.3Fuhi Red, Xbh.n Eqmic D.vdopm.nl Zon.. Wui2l410l Jai$u, Chind T€ri+s65103S214s67 Fd: +3651033200423 E-roil:mNumap.d'[email protected] TEST REPORT NUMBER: WIiXH00002719 TESTS CONDUCTED {B) RoHS REOUIREMENT; RESTRICTED ST'BSTANCES CADMII'M (Cd) LEAD (Pb) MERCURY (Hg) CHROMIUM(Vr ) 0.18 (1000nq/kq) (PBBS) poLyBRoMrNATEpDTpHENyLerpeis (1000 lhq/kq) (1000 ftqlkq) (1000 mq/kq) 0.13 0.1S 0.I* (cr6*) POLYBROM]NATED BIPHENYLS LIIfiTS {100 mq/kq) 0.01* (pBDE=) 0.18 (1000nq/kq) THE ABOVE LIMITS WERE QUOTED FROM 2002l95/EC 2 0 0 5 / 6 1 8 / E C F O R HOMOGENEOUSMATERIAL. AND AMENDMENI (C) TEST METHOD: TESTT}TG ITE!{ CADMIUM (Cd) CONTENT TBSTII{G METHOD WITH REFERENCETO IEC 62321 EDfTION 1.0: 2008, By ACID DIGEST'ION AND DETERMINED BY ICP- REPORTI}IG LIXTT 2 rlg/kg cEs LEAD (Pb) CONTENT WITH REFERENCEtO TEC EZ:Zr EDfTION 1.0: 2008, By ACID DIGESTION AND DETERMTNED BY ICP- MBRCURY (Hg) CONTEIII WIIH REFERENCETO rEC 52321 EDITION 1.0: 2008, BY ACID DIGESTION AND DETERMINED BY ICP- 2 r'|.g/kg oEs 2 ng/kg oEs CHROMIUM(V1) (Cr") CONTEMI (FOR META],) WITH REFERENCETO IEC 62321 cDITION 1.0: 2008, BY BOII,ING WATER EXT&\CTION AND DBTERMINED BY I]V-VIS SPECTROPHOTOMETER O.o2ng/kgWITH 50cm' (IN TESTING SOLuIION) POLYBROMINATED BIPHENYLS (PBBS) & PO'JYBROMINATAD DIPHENYL ETHERS (PBDES) WITH REFERENCETO IEC IEC 62321 EDITION 1.0: 2008, BY SOLVENT EXTRACTION AND DETERMINED BY GC/MS AND FURTHER HPLC CONFIRMATION i{HEN NECESSARY. s mglkg DATE SAMPITERECEMD:AUG A2 , 2OaO T E S T I N G P E R I O D : A U G0 2 , 2 0 1 0 T O A U G 0 5 . 2010 TO BE CONTINUED IntertekT€sttngSedices Wuxi Ltd. rlo.3 Fob€iRoad,Xish.n E6Mi. DddoBi€nr Zoe, wui214101.iaosu chln, Td: +365 0 332t 4s57 Fa* +s{rs to a32oo42s E-n.,t @3um€rcood6w.@id€d.r 6n TEST REPORT NUMBER: W(IXHo00 02 719 TESTS CONDUCTED (D) MEASUREMEITIIFITOWCHART : TEST FoR cd/ pb /Hg / cr (vr ) /pBBe/pBDEB coNTErvrs REFERENCESTANDARD: IEC 6232A EDITION 1.0: 2008 SA{PTING/GRINDINC MATERIAJ,, COTFIRi{ OR CII'ITINC DICEST TIIE I v TrlE TESI@ f-----";;;;---I ExrrAcrroN oR I ----T--so!!'EN'f E.rRicrroN I I I I f*'*"^,"",G;l EXTFTCTAND I I -r- MAxr uP Nr.lI{ I | INORGANIC (ANN LUO/FRED WANG/AI,LY WAN) ORGANIC {.]ENNY XUICHERRY STJN) REMARKS: *1: I,IST OF APPROPRIATE ACID: CHEMIST: MATERIAIJ ACTD ADDED FOR DIGESTION METALS t{No3.Hc1,HF, HrO,.H3BO3 HNO3,HC1,HF ELECTRONICS HNO3,HCl , H'O',HBF4 POLYMERS *2: IF THE RESULT OF SPOT TEST IS POSITIVE, CHROIi'IIUM vI BE DETERMINEDAS DETECTED. WOULD TO BE CONTINUED PAGE 4 OF 7 IntertekT€stingSeavlc$WuxiLtd. No 3 Fub.i Rod Xishe E@imL o.wrom.nl 20^6 wu, 214101,Jidn!{. China E-mail dsufi.roood.8u@intsl6k.@m T.l: €6 510 3321 4567 TEST REPORT NUMBER:mJxHo0 002 719 TESTS CONDUCTED ( I ) TEST RESUIIT SUMMARY TIAIJOGEN CONTENI : TESTING ITEM (F) FLUORINE CONTENT CHLORINE (CI) CONTENT BROMINE {BT) CONIENT IODINE (1) CONTENT RESULT (Dprn) ND ND ND ND ppm = PARTS PER MTLLTON = mglkg = NOT DETECTED ND DATB SAMPLE RECEIVE: AUG 02, 2010 TESr PBRIOD: AUG 02, 2010 TO AUG 0s, 2010 REI4ARKS : (II ) TEST METHOD: TESTING ITEM H A L O G E N( F , C l , CONTBIfT REMARKS : Br,I) REPORTING LIMIT TESTING MBTHOD REPORTING LIMTT WITH REFERENCETO IEC 611892.2006 BY COMBUSTIONFLASK AND DBTERMINED BY ION CHROMATOGRAPHY = QUANTITATION ],IMIT 50 ppm OF ANAI,YTE IN SAMPI,E TO BE COITIIINUED PAGE 5 OF 7 IntertekT6ting ServicesWuxlLtd. r{r.3 FubdRo.d.xEh3nEdimlc oa!}tpm|n zom wu 214101,lan$ucl'ina 4567 Fd:+365103320(x23ErMl: @[email protected] T€r +35510SS21 TEST REPORT NTJMBER: WUXHO0oo2719 TESTS COM)UCTED (lI1) MEASITREMENT FrrowcHART: TEST FOR HALOCENCONTENT REFERENCE METHOD:IEC 61189-2 TEST 2 C r 2 SA.I4PLING/GRINDING OR CIfTTING ADD AISORBEI.TT IN A COMBUSTION FI,ASK & PLACE WEIGIiED SAMPIIE IN FILIJ THE COMBUSTION FI,ASK WITI] OXYGEN IGNITE THEN LE'IVE ROOM TEMPERATURE TI{E FIIASK AT ANY TEST SPECIMEN IN THE COMBUSTION FLASK? TRANSFER THE ABSORBENT INTO A VOIIUMETRIC FI.ASK CHEMIST: FRED WANG/ ALty wAN TO BE CONTINUED PAGE 6 OF ? IntertekTestingServlcesWuxiLtd. No.3Fub€iRoad,XkhenE@hmic D.v€toprn.itZoq wqi 214101. Jtaosu,chn. Te : €6 5103€214567 F€x +A6s103320042A E-nait:@nsum.rgoo&wuxi@ide1ck.€m NUMBER: WUXHo0002 719 TESTS CONDUCTED PHOTO END OF REPORT PAGE 1 0 8 1 IntertekTeallng S6rvicesWuxl Ltd. No.3Fubii Rora.xi.h.n E@|mio D.wloprn.ni zd., Wui 214101, Jiano&,ChiE Eftir:@rc|ma..&[email protected] Fs +3351033200123 TBST REPORT APPLICANI: NUMBER:wtIXHo0002721 CONCORD SEMICONDUCTOR(WUXI ) CO., I,TD. EAST ].#, ZHENFA 6 ROAD, SHUO PANG INDUSTRIAI PARK WIIXI NATIONAIJ HIGHTECH DEVELOPMENT ZONE, WUXI,.JIANGSU,CHINA ATTN: ZttANG XIAOPENG DATE: AUG 06, 2 010 SAMPIJEDESCRIPTION: ONE(1)PIECE OF SIIBMITTED SAMPLE SAID TO BE :nHITE pOwDBR. ITEM NAME : WAFER PASSIVATTON. VENDOR : PROPRIETY. COMPONENTOR PART NO. : PROPRIETY. TEST TTEM : Pb, Cd,Hg, CIVI, PBB PBDE,F,Cl,Br,I. TESTS CONDUCTED: AS REOUESTED BY THE APPLICA}II, FOR DSTAILS REFER TO ATTACHED PAGE(S) TO BE CONTINUED PREPARED AND CHECKED BY: FOR INTERTEK TEST]NG SERVICES WI'XI LTD. .]ESSICA ],U GENERAL MANAGER PAGE I lnle.tek T$ting ServicesWuxi Ltd. No3 Fub.i Rod, x€hs E@nomic O.v.lopm..l Zono Wuxj214101, Jia.ge China +46 Fax 51033200423 E-m.il d3umeEoodsru @inidr.k.@m OF 7 TEST REPORT NITMBER: WUXHo00 02 721 TESTS CONDUCTED {A) TBST RESULT SUMMARY: IESTI}IG ITEIN CAI)MIUM (cd) CONTEIflI (mg/kg) LEAD {Pb) CONTENT (mq/kq) MERC,I'RY (Hg) CONTEI\TT (mg/Kg) (vr) CHRoMIUM (cr'*) coNTENr (ns/kg) (FOR NON-METAL) POLYBROMINATED BIPHENYLS (PBBS) MONOBROMOBIPHENYLS (MonoBB) DIBROMO BIPHENYLS (DiBB ) TRIBROMO BIPHEI.IYLS (TTiBB) TETRABROMOBIPHENYLS (TeETaBB) PENTAIIROMO BIPHENYLS ( PENIABB) HEXABROMOBIPHENYLS (HexaBB) HEPTATIROMOBIPHENYLS (HeptaBB) OCTABROMOBIPI{ENYI,S (ocTaBB) ]ICIfAIIROMO BIPHENYLS (NonaBB) DECABRO}.,IOBIPHENYI, (DecaBB) POIJYBROMINATED RESI'],7 ND 207400 ND I.ID DIPHENYIJ ETHERS (ng/kg) ND ND ND ND ND ND ND ND ND ND (PBDEg (nslkg) MONOBROMODIPHEI{YL ETHERS (MonoBDE) DIBROMO DIPHENYL ETHERS (DiBDE ) TRIBROMO DIPHENYL ETHERS (TriBDE) TETRABROI.,IODIPHE}MJ ETHERS (TetraBDE ) PEIVTABROMODIPHENYL ETHERS (Pent.aBDE) HEXABROMODIPHENYL ETHBRS (HexaBDE) HEPTABROMO Df PHENYIJ ETHERS (HeptaBDE) OCTABROMODIPHENY], ETHERS (OctaBDE) NONABROMODIPHENYL ETHERS (NonaBDE) DECABROMO DIPHENYL ETHER {DecaBDE) ND ND ND ND ND ND ND ND ND ND REMARK: Mg/Kg = MII,LIGRJUTI PER KILOGRAM BASED ON DRY WEIGHT= DDM ND = NOT DETECTED # = THE RESULT IS FOR REFERENCE ONLY TO BE COIITINUED PAGE 2 OF 7 Intetek Testing Se.vicesWuxl Ltd. No 3 Fub.i Ro.d xighan E@imic ti*ropmd zom Wuxj214101.Ji.ng6u,China T. : +36 510 3321 !1537 F.x +s6 510 3320 0423 E-m.it 6.ufr.r9oodsru @inr€riok.@m TEST REPORT NUMBERI WUXHo00 02 721 TESTS CONDUCTED (B)RoHS REQUIREMENT: RBSTRICTED SI'BSTANCES CADMIT'M (Cd) LBAD (Pb) MERCURY (Hq) 0.01t 0.19 0. 1t (1000 mq/kq) (1000 mq/kq) CHRoMIUM(vI) 0.1t {1000 ng/kg) IJIIdITS (Cr"') (100 mqlkc) PO'JYBROMINATED BIPHENY],S {PBBS) 0 . 1 * ( 1 0 00 m g / k g ) PO],YBROMINATED DIPHENY], ETHERS (PBDEE) 0.1* (1000mq/kq) THE ABOVE LTMITS WEREQUOTEDFROM2002l9slEc AND AMENDMET.]'T 2 0 0 5 / 6 1 8 / E C F O R HOMOGENEOUS MATERIAL. (c) TEST METHOD: CADMIW (Cd) CONTENT REPORTI}IG I.IINIT TESTING MBTBOD TESTIITG ITB!i WITH REFERENCBTO IBC 62321 EDITION 1.0: 2008. BY ACID DIGESTION AND DETERMINED BY ICP- 2 mg/kg oEs LEAD {Pb) CONTEI{T WITH REFERENCETO IEC 62321 EDITION 1.0: 2008, BY ACID DIGESTION AND DETERMfNED BY ICP- MERCURY (Hg) CONTENT WITH REFERENCETO IEC 62321 EDITION 1.0: 2008. BY ACID DIGESTION AND DETERMINED BY ICP cI{ROMltM (Vr) (cr6.) CoNTENT (FOR NON-METAL) WITH REFERENCE TO IEC 62324 EDITION 1.0: 2008. BY ALKAI,INE DIGESTION AND DETERMINED BY UVVIS SPECTROPHOTOMETER 2 (tg/kg oEs 2 (E/ks oEs l WITH REFERENCETO IEC IEC 62321 POLYBROMINATED BIPHENYLS {PBBS) & E D I T I O N 1 . 0 : 2 0 0 8 , B Y S O T , V E N T EXTRACTION AND DETERMINED BY POI,YBROMINATED GCIMS AI{D FURTHER HPI,C DIPHENYL ETHERS (PBDES) CONFIRMATION WHEN NECESSARY. mg/kg 5 mglkg DATE SAMPLE RECEIVED;AUG 02' 2070 TESTING PERIOD:AUG02, 2010 T0 AUG 05, 2010 TO BE CONTINUED PAGE 3 OF 7 Intadek Testing SorvicesWuxl Ltd. No s Fubd Red Xshan E@omic Dov€lopm.nl Zoi., Wui 21d101,Jiang&,ChiE sui@ml€n€k @m Fa* +36 510 sa20 0423 E-m.rL:dtum.Eo.d. TEST REPORT NUMBER:WUXHo0 002 ?21 TESTS CONDUCTED (D) MEASUREMENT'FLOWCHART: TEST FOR cd/ Pb /Hg / cT (VI) /PBBS/PBDE8 coNTENTs REFERENCESTANDARD: IEC 6232I EDITION 1.0: 2O0g salrPrrNc/cirMrNc oR orrNc SA!{PI]ES ARE TOTAIIIIY IAKE UP I,IIIH DEIONIZED WATIR AND AD! DIPIIhIr! CARBAZIDE SOII}TION i}IAIIYZED BY W-VIS INORGANIC (ANN LUO/FRED WANG/AI,],Y WAN) ORGANTC (,fENNY XUICHERRY SUN) REMARKS : *1: LIST OF APPROPRIATE ACID: CHEMIST: MATERIAI, ACID ADDED FOR DIGESTION POT,YMERS llto3 HcI, HF, H'o2_HrBo3 META],S HNO3.lICl , HF ELECTRONTCS HNO3,HCl, HrOr,HBF4 *2: IF THE RESIILT OF SPOT TEST 1S POSITIIT, CHROMIIIM VI BE DETERI4TNED AS DETECTED. WOULD TO BE CONTINUED PAGE 4 OF 7 IntertekTesting Se ices Wuxi Ltd. No.3 Fub Ro€d,Xbh.n E@|mic D6v€lop.i6nt n6, Wqj214101 J.ngsu,ChnE T.r ]36 510 33214567 Fd+365103320M23 E.roit: @n{[email protected] TEST REPORT NUMBER: W11XH00002721 TESTS CONDUCTED { I ) TEsr REsuLr strMl,rARy HALOGEN CONTENT : FLUORINE (F) CHLORINE (C1) BROMINE (BT) IODINE {I) RESULT (ppm) TESTING ITEM CONTENT CONTENI COMIENT CO}IIEIfT ND ND ND ND REMARKS : ppm = PARTS pER MILLION = mg/kg = NOT DETECTED ND DATE SAI\{PLERECEM: AUc 02, 2010 TEST PERIOD: AUG 02, 2OLO TO AUG 05. 2010 II ) TEST METHoD TESTING ITEM H A L O G E N( F , C l , CONTENT REMARKS : Br,I) REPORTING LIMIT TESTING METHOD REPORTING LlMIT WITH REFERENCETO IEC 61189. 2.2006 BY COMBUSTIONFLASK AND 50 ppm DETERMINED BY ION CHROMATOCRAPHY = QUANTITATION LIMIT OF ANAI,YTE IN SAMPIJE TO BE COIfIINUED PAGE 5 o F 7 IntertekTesting ServicesWuxi Ltd. No.8Fuhi R@d,XishanEotffiio D.vgop.n nlzo.., wid 214101.r.noru,CNn. r[167 Fd +Aa5108Sm042S T.l +355103321 E-@ir:@[email protected] TEST RBPORT NUMBER: WIIXIIOOO02721 TESTS CONDUCTED i III ) MEASUREMENT Fl,owcraRT: TEST FOR HALOGENCONTENT REFERENCE METHOD:IEC 61189-2 TEST 2C12 SAMPIJING/GRINDING OR CIIITING ADD ABSORBEI.ITIN A COMBUSTION FLASK & PLACE WEIGHEDSAIVIPLEIN FIIJII THE COMBUSTION FIASK OXYGEN IGNITE TI{EN I,EA\'E ROOM TEMPERATURE WITH THE FI.ASK AT ANY TEST SPECIMEN IN THE COMBUSAIOT.i FI,ASI<? TRANSFER THE ABSORBEITI VOIIUMETRIC FI'ASK INTO A CHEMIST: FRED WANG/ALLY WAN TO BE COI{TINUED PAGE 6 OF 7 IntertekTeatlngServicesWuxi Ltd. N..3 Fub.' Ro.d,Xilh.n E@tmio D.veloprn.d24., wui 214101, Janoe!,Ctin. +3651033214567 E-roir:[email protected] TEST REPORT NUMBER: WIIXHo0002721 TESTS CONDUCTED PHOTO END OF REPORT PAGE 7 0 F 7 InteftekTestlngSsrvlcesWuxiLtd. Zorc, No3 Fub.i RoadXi.ha. E@nmE o*loprer Wuxi214101, Ji.n$u chin. re : +365103€214567 E-nail:6n.om€4ood3 wur@inl6'lek.@m NUMBER: WIIxHo0 002 72 9 APPLICANT: CONCORDSEMICONDUCTOR (WUXI) CO., LTD. EAST 1#, ZHENFA 6 ROAD, SHUO FANG fNDUSTRIAL PARK WII) T NATIONAIJ HIGHTECH DEVELOPMENT ZONEI WIIXI, JIA}IGSU, CHINA ATTN: ZHANG XIAoPENG DATB: AUc 06, 2 010 SAMPLE DESCRIPTION: ONE(1)PIECE OF SUBMITTED SAMPLE SAID TO BE :COPPER META],. ITEM NAME I,EAD FRAME MATRIX/TO-220 LEAD FRAME/COPPER SPACER. VEI.|DOR ,_lII{ LIN TECHNOITOGYCO. , LTD. COMPONENTOR PART NO. COPPER. TEST ITEM Pb, Cd, Hg, CrVI . TESTS CONDUCTED: AS REOUESTED BY T'HE APPLTCU{T, SUMMARY: TESTED gAt6PI,E SUBMITTED SAMPIJE POR DETAILS REFER TO ATTACHED PAGE (S) STT}TDARD WITH REFERENCE TO TBST METHOD OF IEC 6232A EDITION 1.0: 2008 AND MAXIMI]M CONCENTRATION IJIMITS QUOTED FROM RoHS DIRECTIVES 2OO2/ 95 /EC AND A].,IENDMENT 2005/67A/EC RESI'IIT PASS TO BE CONTINUED PREPARED AND CHECKED BY: FOR INTERTEK TESTING SERVICES W(IXI LTD .]BSSICA I,U GENERAL MANAGER PAGE 1 0 F 5 Inte*ekTestingSarvlcesWuri Ltd, No.8 Fub€i R@4 Xlhan Eonomi Wui 214101,Ji.^gs, Chi^. E4.tr: dsum.Eood'sd@iiid6k on TBST REPORT NIIMBER: WIIXH00002729 TESTS CONDUCTED (A) TEST RESULT SUMMARYI TBSTTNG ITE![ CA.DMIIJM (Cd) CONTENT (mg/kg) LEAD (Pb) CoNTENT (mg/kg) MERCURY (Hg) CoNTENT (mg/kg) (vr ) (cr"'J-REsuLT cHRoMrIrM BOILING RESUI.T ND WATER EXTRACTION (mq/kq wrrH 5ocm'?) ND ND {By ON METAL) REMARK: mg/kg = MILLIGRI!4 PER KILOGRAM BASED ON DRy WEIGHT= ppm ftg/kg WITH 50cft, = MILLIGRAM PER KILOGRAM WITH 50 SOUARE CENTIMETER ND = NOT DETECTED (B) RoHS REOUIREMETflI: RESIRICTED SI'BSTANCES CADMIUM {Cd) LEAD ( Pb) 4EIquRY (Hs) CHRoMIUM(vr I 1st", IJI![ITg 0.01t 0.1* 0.1t 0. Lt (1 0 0 (1000 (1000 (1000 mq/kc) mglkq) rnclkq) rnqlkq) THE ABOVE LIMITS WERE OUOTED FROM ZOOZISS,TEC AND A].,IENDMENT 2OO5/ 6TA /EC FOR HOMOCBNEOUSMATERIAIJ. TO BE CONTINUED PAGE 2 0 F 5 InteltekT*tlng SeJvlces WuxiLtd. No.8 Fubti Re4 X!ha. E@nonic Oar.lophd Z!rc, wud 21,t101,Ji..€&. china T.l €651033214567 F4: +36 510 3a200423 [email protected] TEST REPORT NIJMBER : WIII{HOOOO2729 TESTS CONDUCTED (c) TEST METHoD: TESTTNG ITEM CADMIUM (Cd) CONTENT LESTING IIBTAOD WITH REFERENCE 'IO IEC 6232I EDITION 1.0: 2008, By ACID DIGESTION AND DETERMINED BY ICP, REPORTI}IG I,IMIT 2 w/kg oEs LEAD ( Pb) CONTENT WITH REFBRENCETO IEC 52321 EDITION 1.0: 2008, By ACID DIGESTION AND DETERMINED BY ICP- 2 llr.g/kg MERCURY {Hg) COlflIENT WITH REFERENCETO lEC 62321 EDITION 1.0: 2008, By ACrD DIGESTION AND DETERMINEDBY ICP- 2 n:tg/kg WITH REFERENCETO ]BC 52321 EDITION 1.0: 2008, By BOTLING WATER EXTRACTION AND DETERMINED BY Try.VIS SPECTROPHOTOMETBR 0.o2mq/kq WITH 50cm' (IN TESTING SO',UTION) oEs oEs CHROMIT]M (VI) (Cr"') CONTENT (FOR META],) DATE SAMPLERECEMD:AUG A2, 2OrO T E S T I N GP E R I O D : A U G 02, 2010 TO AUc 05, 2010 TO BE CONTINUED PAGE 3 OF 5 IntertokTesUngServicesWuxi Ltd. No.3Fob€iR@d,xi.han E@ofiic D.vdopfi. zonq wqi 21,t101Jiangsu, chiF Td: +3551033214567Fax +365103320 0423 E-mj: [email protected] TEST REPORT NIIMBER: WIjXHo0002?29 TESTS CONDUCTED (D) MEASI]REMENT FI,OWCHART: TEST FOR Cd/Pb/Hg/Ct (VI ) CONTENTS RBPERENCE STANDARD: IBC 62327 EDITTON 1 0 : 2 0 0 8 SAI4FIINC/GRI\OINC OR CTTr|ING sll4FllEsAi!ToTAI,LY ANAIYZED BY ICP OlS VIATER AND ADD DIPHEIIY'J' CXRBAZIDE SOIJ'TION NNA]LYZED 3Y I].V-VIS CHEMTST: INORGAN]C (AI\T}TLUO/FRED WANG/AI,I,Y WAN) REMARKS I * 1 : L I S T O F A P P R O P R I A T EA C I D , MATERIAIJ POLYMERS METAI,S EIJECTRONlCS ACID A.DDED FOR DIGESTION x,ro!.HcI, HF, I{,O, H3BOr IINOr,HCf, HF l{No3 Hc1, HrO2.HBF4 *2: TF THE RESULTOF SPOT TEST IS POSITM, BE DETERMINEDAS DETECTED. CHROMIUI4 VT WOULD TO BE CONTTNUED PHOTO PAGE 4 OF 5 IntertekTesting ServicesWuxi Ltd. l,lo.3Fub.i Re4 xsh.n Edomic o€vdopm€.t&F Wqi 214101, Jiange,Chin. +36 T.l: 51034214567 Fax +355103320(X23 Efltt: @um.Eood6.sui@intstek.@m TBST REPORT NUMBER: WUXHo0 002 ?2 9 TESTS CONDUCTED END OF REPORT PAGE 5 OF 5 IntertekTeatlngServicesWuxi Ltd. No.3 Fub., R@4 Xsh8n E@nomic D.velopns zom E-mail [email protected] @ TBST NEPORT APPLICAIflI: NUMBER: w 1 ] x H 0 0 0 0 2 7 3 0 COr\TCORD SEMICOM)UCTOR(WUXI ) CO., LTD. EAST 1+, ZHENFA 6 ROAD, SHUO FANG INDUSTRIAL PARK WT.].XINATIONAIJ HIGHTECH DEVELOPMEI!'I ZONE, WlIXI, .fIANGSU, CHINA ATTN: ZIIANG XIAOPENG DATE; AuG 06, 2O1O SAI,IPLE DESCRIPTION : ONE(I)PIECE OF SUBMITTED SAMPLE SAID TO BE :COppER METAT. ITEM NAME LEAD FRAME/I,EAD FRAME MATRIX/TO-220 FRAME/ HEATS INK . !ENDOR JINAN JIHLONG TECHNO',OGY CO. , LTD. COMPONENTOR PART NO. COPPER, Pb, Cd, Hg, CrvI . TESTS CONDUCTED: AS REQUESTED BY T'HE APPLICAIIT, SUMMARY: TESTED SA.!{PI]E SUBMTTTED SAMPIIE FOR DETA]LS ],EAD REFER TO ATTACHED PAGE(S) STAI{D}RD WITH REFERENCE TO TEST METHOD OF IEC 6232I EDITION 1.0: 2008 AND MAIIMI]M CONCENTRATION I,IMTTS QUOTED I'ROM ROHS DIRECTIVES 2AO2/ 95 /EC AND AMENDMENT RBSI'',7 PASS 2A05/618/EC TO BE COMIINUED PREPARED AND CHECIGD BY: FOR I}.]'TBRTEK TESTING SERVICES WUXI LTD .]ESSTCA LU GENERAL MANAGER PAGE 1 0 F 5 IntertekT6ting ServicesWuxiLtd. fkr.3 Fubd R€d, x.n.n Edomic D.v.lopm.nt zon.. Wqi 214101, Ji.nq$,ChiE +36 Td: s103321,1567 F*+Aa5103S200|23 E-mit:@n5uml9pod'*un@ d€n€k6m TEST RBPORT NUMBER: WIIXHo00 02 73 O TESTS CONDUCTED (A) TEST RESULT SUMI4ARY: TESTI!{G ITETI RBSI'LT CADMIITM (cd) CONTEITT (mglkg ) ND LEAD (Pb) CoNTENT (mglkg) 23 MERCURY (Hg) CoNTENT (mglkq) ND CHROMITJM (VI) (cr.-) RESULT IBY ND BOI],ING WATER E.XTRACTION ON METAI,) (mq/kq wrrH 5 ocm'?) REI,IARK: mg/kg = l41111gRl1{ PER KIITOGRAM BASED ON DRy WEIGHT= ppm m g / k g W I T H S O c m ' = MILLIGRAM PER KILOGRAM WITH 50 SOUARE CENTIMETER ND = NOT DETECTED (B) RoHS REOUIREMENTI RBSTRICTBD SI'BSTAIICES CADMIU}.,I (Cd) 0 . 0 1 t ( L 00 m g l k q ) LEA.D ( Pb ) 0.1t (1000 mglkq) MERCURY {Hg) 0.1? (1000 mglkg) (Cr'*) CHROMIIIM (VI) 0.1* (1000 mq/kq) THE ABOVE LIMITS WERE OUOTED FROM 2AO2/95/EC ErI,O AMTNU SNT 2OO5/ 618 /EC FOR HOMOGENEOUSMATERIAI. TO BE CONTINUED PAGE 2 0 F 5 Intert.kTe6tlngSedicesWuxi Ltd. rlo.3 Fub€iRo.d,xish.n E@nomicD6!€topm. zoie. Wui 214101, Jangsu, Chia +36510332145a7 Fa. +3651033200423 E-mait: @m0ftrloods.wuxi@i. cn6kM TEST REPORT NUMBER: W(.rxHo0 0 02 73 0 TESTS CONDUCTED (c) TEST METHOD: REPORTIIIG I,II{IT TESTING ITBM IESTING CADMII]M (Cd) CO}IIENT WITH REFERENCETO ]EC 62321 EDTTION 1. 0 : 2 O O 8 , B Y A C I D DIGESTION AND DETERMINED BY ICP- LEAD (Pb) CONTENT WITH REFERENCE 'IO IEC 62321, EDITION 1.0: 2008, BY ACID DTGESTION AND DETERMINED BY ICP- 2 ng/kg MERCURY (Hg) CONTENT WITH REFERENCE 'IA IEC 62321 EDITION 1.0: 2008, By ACID DIGESTION AND DETERMINED BY TCP. 2 ng/kg UBTHOD 2 mg/ks oEs oEs oEs CHROMII'M (VI) (Cr"') COMIENT (FOR META],) WTTH REFERENCE TO IEC 62321, EDITION 1.0: 2008, BY BOILING WATBR EXTRJ\CTION AND DBTERMINED BY W-VIS SPACTROPHOTOMETER DATE SAMPLE RECEMD:AUG 02 , 2O1O TESTING PERIOD:AUG 02, 2010 TO AUG 05, 0 . 0 2 m q/ k o WITH s-Ocm-' (IN TESTING SOLuIION) 2O1O TO BE COI{TINUED PAGE 3 OF 5 IntertekTettlng ServicesWuxi Ltd. No.3 F!b., Red, x3h.n E@ onic D.tdopm.nt Zoi. Wqi 214101,Ji.ng$, Chin. €651043214567 Fq €4s10332o(x2a E nait:6sum.r9oods.wut@inr€rt k.@m TBST REPORT NUMBER:WUXHo0002?30 TESTS CONDUCTED (D) MEASUREMENT P],OWCHART; TEST FOR cd/Pb /Hg/C:E (v1)CONTENTS REFERENCESTANDARD: IEC 62321 BDITION 20aa A9FROPRIATE ACID.T SAMPLES AIIE ToTAI,I,Y E1IC UP WITH DEIONIZED clRBAZrDr SOIUTION CHEMIST: II.IORGANIC (ANN LUO/FRED WANG/A],I,Y WAN) REMARKS : *1: LIST OF APPROPRTATEACID MATERIAL ACTD ADDED FOR DIGEST]ON POLYMERS r$ro3.HcI, I{F, I{2O' H3BO3 I.,lETALS IiNO3.HC1,HF ELECTRONICS rrNo3.Hc1, Hro:.HBF4 *2: IF THE RESIILT OF SPOT TEST IS POSITIVE. CHROMIIIM VI WOULD BE DETERI4INED AS DETECTED. TO BE CONTINIJED PHOTO PAGE 4 OF 5 IntertekTesting ServicesWuxi Ltd. NoB Fub.i Ro* Xbh.n E@ffiio Dcvdop,n.nrzon., wurl 214101. .ns$!, chn. I€r:+46510s42146?Fax+A65r0 33200423 E-roir:@n$mr!.od'wur@rn€n€k6m TEST REPORT NUMBER: WttXHo0002730 TESTS CONDUCTED END OP REPORT PAGE 5 0 F 5 IntertekT€tlng ServicesWuxiLld. w0i 211101, Jianse,china T.i+3651034214567Fa +3551033200423 E-m.ll:M3um6Eood..sul@inr€ri.k.@m TEST REPORT APPLTCANI: NWBER: wlIXHo00 02745 CONCORD SEMICONDUCTOR(WTIXI) CO., I,TD. EAST 1#, ZHENFA 5 ROA.D, SHUO FANG INDUSTRIAL PARK WUXI NATTONAI, HIGHTECH DEVELOPMENT ZONE, WI]''(I , ,f IANGSU. CHINA ATTN: ZHANG XIAOPENG DATEt AUG 05, 2O1O SAMPLB DESCRIPTION: ONE(1)PIECE OF SUBMITTED SAMPLE SAID TO BE :OREY PASTE, ITEM NAME SOLDER PASTER. VENDOR HERAEUS MATERIAI,S TECHNOI,OGY SIIANCHAI LTD. COMPONENTOR PART NO. F367SN10-90P8. TEST ITEM P b . C d , H g , C r V I , P B B P B D E ,F , C 1 , B r , I . TESTS CONDUCTED: AS REOUESTED BY THE APPIJICANT. FOR DETATIJS REFER TO ATTACHED PAGE(S) TO BE CONTINUED PREPARED AND CHECKED BY: FOR TNTERTEK TESTING SERVICES WUXI IJTD. .fESSICA ],U GENERAI, MANAGER PAGE 1 OF 7 IntertekTostingServicesWuxl Ltd. No 3 Fub€[email protected] EenomicONIoD@^l zon., wuxi21,1101. Jianetu, chin. F.x +3651033200423 E-mail:@i$ruaood!.wlr@ir€n€k@m TEST RBPORT NUMBER: mIXHo0 0 02 745 TESTS CONDUCTED (A) TEST RESULT SUMI'ARY: TES?I}IG ITEX CADMIIIM (Cd) coNrENI (mg/kg) LEAD (Pb) CoNTSNT (mglkg) MERCURY {Hg) CoNTENT (mglkg) CHROMIUM(vI) (Cr".) COrrer.Ir (mglgJ (FOR NON-METAL) POLYBROMINATED BIPHENYLS (PBBg) MONOBROI',IO BIPHENTLS (MonoBB) DIBROMO BIPHENYLS (DiBB) TRIBROMO BIPHENY],S (TTiBB) RESI'',7 ND 932600 ND li"D (mglkg) TETRABROMO BIPHENYLS (TeITaBB) PENTABROMO BIPHENYITS ( PentaBB) HEXABROMO BIPHBNYLS (HexaBB) (HeptaBB) HEPTABROI.{OBIPHENfLS (OCTABB) OCTABROMOBIPHENYLS NONABROMOBIPHENYLS (NonaBB) ND ND ND ND ND ND ND ND ND ND DECABROMOBIPHENYL {DecaBB) POLYBROMINATED DIPHENYI, ETHERS (PBDES (ms/kg) MONOBROMODIPHENYIJ ETHERS (MonoBDE) ND DIBROMO DIPHENYL ETHERS (DIBDE) ND (TriBDE TRIBROMO DIPHENYL ETHERS ND ) TETRABROMO DIPHENYII ETHERS ND (TetraBDE) PENTABROMO DIPHENYL BTHSRS ND ( PentaBDE) HEXAI}ROMO DIPHENYL ETHERS (HexaBDE ) ND HEPTABROMO DIPHENY'J ETHERS ND (HeptaBDE ) OCTABROMODIPHENY], ETHERS (OCI BDE) ND (NonaBDE) NONABROMODIPHENYL ETHERS ND DECABROMODIPHEI{YL ETHER (DecaBDE) ND REMARK: mg/Kg = MILLIGRJU,{ PER KITJOGRAMBASED oN DRY WEIGHT= ppm ND = NOT DETECTED # = THB RESULT IS FOR REFERENCE ONLY TO BE CONTINUED PAGE 2 OF ? IntartekTeatlngServicesWuxiLtd. No.8Fub!, Re4 xsh€h E@nomic o.v.lorm..r zoB Wui21tl01, Jia.g&.Chin. T.l+s551036214567Fa{ +36510s4200423 E maildsun.rgood. [email protected] TEST REPORT NUMBER: WUXHo00 02 745 TESTS CONDUCTED (B)RoHS REQUIREMENT: REgTRTCTED ST'BSTTNCES TJMITS CADMII]M {Cd) 0.01t (100 mq/kc ],EAD ( Pb) 0.18 (1000 mq/kq MERCURY {Hs) 0.1? (1000 mglkg CHRoMIUM (vI ) (cr't) 0.1? (1000 mq/kq POLYBROMINATED BIPHENY],S (PBBg) 0.1& (1000 mg/kg POLYBROMINATED DIPHENYL ETHERS (PBDEg) 0.1t (1000 mq/kq THE AEOVE IJIMITS WERE QUOTED FROM200219slEC AND AMENDMENT 2OA5/ 614/EC FOR HOMOGENEOUS MATERlAL. (c) TEST METHOD: TBSTI}IG CAIMIUM CONTEIII ITEU (Cd) RBPORTIIIG TESTING IfETIIOD IJIIIIT WITH REFERENCETO IEC 62321 EDITION 1.0: 2008. BY ACID DIGESTION AND DETERMINED BY ICP- 2 tng/kg oEs WITH REFERENCETO IEC 62321 EDITION 1.0: 2008, BY ACID D]GEST]ON AND DETERMINEDBY ICP- LEAD ( Pb) CONTENT 2 tfg/kS oBs MERCURY (Hg) CO}IIENT CHROMIIJM{V]) (cr6*) CoNTENT (FOR NON-METAI,) NTTH REFBRENCETO IEC 52321 EDITION 1.0: 2008, BY ACID DIGESTION AND DBTERMINED BY ICP, f,ES WITH REFERENCETO IEC 62321 EDITION 1.0: 2008, BY ALKALINE DICESTION AND DETAR!,IINED BY WVIS SPECTROPHOTOMETER POLYBROMINATED WITH REFERENCETO TEC IEC 62321 (PBBS) BIPHENYI,S & EDITION 1.0: 2008, BY SOLVENT POLYBROMINATED EXTRACTION AND DETERMINED BY DIPHENY], ETHERS GCIMS AND FURTHER HPLC ( PBDEs) CONFIRTIATION WIIEN NECESSARY. DATE SAMPLE RECBII€D:AUG 02, 20aO T E S T I N G P E R I O D : A U G0 2 . 2 0 1 0 T O A U G 0 5 , 2 mg/kg l rng/kg s mg/kg 2010 TO BE CONTINUED PAGE 3 OF 7 IntertekTestlng ServicosWuxi Ltd. No.3FubrtR@d,Xi.na. E@omic D.ldopm.ri Zone. Wqj 214101, Ji.ng$,Chins Fdr *36 510S3200,123E-m.l:Msuh6rOood3.sdl@hlstok @m T.l +3551033214567 TEST REPORT NUMBER:WUXHoo 0 02 ?45 TESTS CONDUCTED (D) MEASTIREMENTFLOWCIIART: (1A/D}:'/pdld, - - , . - t)\ t a / P B B 6 / P B D E S C O I f T E N T S REFERENCESTANDARD: IEC 6232I EDTTION 1.0: 2OO8 SNMII,ING/GRINDINC II'ATERIA!, OR CIN'TING DICEET TIIE I ,'{AI(3 IJP WIII{ DEIONIZED WATER AND ADD DIPHENYI, CNRBAZIDE SOI1ITION AIIA',IZED BY lrv'VIS INORGANIC (ANN I,UO/FRED WANG/ALI,Y wAN) ORGANIC (..]BNNY XU/CHERRY SUN) RE}4ARKS : 11: LIST OF APPROPRIATE ACID: CHEMIST: MATERIAT ACID ADDED FOR DIGESTION POLYMERS HNO],HC], HF, H,O, HrBOr UETALS IINO3,HC1,HF E],ECTRONICS I{NO. HCI , H,O, HBF, *2: IF THE RESIJLT OF SPOT TEST IS POSITM, CHROMIITMVI BE DETERMINED AS DETECTED. WOULD TO BE COIfTINUED PAGE 4 OF 7 IntertekTestingServicesWuxl Ltd. No.€Fubri Red, xshan E@nofricDeldoon€ zon. Wu211101,Ji.ng$, Chin. T.l+365103321,1557 Fax+3651034200423 E nail M.un.Qoodt*ui@int€r16k6f, TES? REPONT NUMBER: WIIXH00002745 TESTS CONDUCTED ( I ) TEST RESTJLTsuMMARy HAI,OGEN CONTENT : RESULT (ppm) TESTING ITEM (P) FLUORINE CO}IIEIflI CHLORINE (C1) CONTENT BROMINE {BT) CONTENT IODINE (I) CONTENT ND ND ND ND ppm = PARTS pER MILLION = mg/kg = NOT DETBCTED ND DATE SAMPIJERECEIVE: AUG 02, 2O1O TEST PERIOD: AUc 02, 2010 TO AUG 05, 2O1O REIIARKS : I[ ) TEST METHoD TESTINC TTEM TIALOGEN {F, Cl. COMIENT REI4ARKS : TESTING METHOD WITH REFERENCETO TEC 611892t2OO6 BY COMBUSTIONFLASK AND DETERMINED BY ION CHROMATOGRAPHY Br, I ) REPORTING IJIMIT = OUANTITATION TJIMIT OF ANAIJYTE REPORTING IJIMIT 50 ppm IN SA],{PLE TO BE COI\]'IINUED PAGE 5 0 F 7 IntertekTesting Se ices Wuxi Ltd. No.3 Fuh.i Rodd. Xlho E@i6ic D.v.lodEnl 26., wui21,1101,Ji6no$, China Fd: +36 5r0 s320 0423 E-mail trsum.rcoods [email protected] TBST REPORT NUMBER:WI]xHo0 002 ?4 5 TESTS CONDUCTED (III) MEASTJREMENT FLowcHART: TEST FOR IALOGEN CONTEITII REFERENCBMETHOD: IEC 61-789-2 .IES.I 2Ci,2 SAMPIJING/GRINDING OR CTITTING ADD ABSORBET.ITIN A COMBUSTION FLASK & PIJACEI4EIGHED SAMPLE IN FIIIII TI{E COMBUSTION FLASK WITH OXYGEN IGNITE THEN IEAVE ROOM TEMPERATURE THE FI.ASK AT ANY TE6T SPECIMEN IN IHE COMBUSTION FI.ASK? TRJANSFERTHE ABSORBENT 1IITO A VOIJUMETRIC FIIASK CHEMIST: FRED WANG/AI,LY wAN TO BE COMIINUED PAGE 6 OF 7 IntertekTeitlng Se.vicesWuxi Ltd. zd6, D.v.loF.nt Nog Fub€i Rod. xish.n EotMb wuli 214101,.Ianor!,Chn. E_mir: @n$meoods wud@id6tuk 6m TBST REPORT NUMBER: WUXHo0002 745 TESTS CONDUCTED PHOTO END OF REPORT PAGE 7 A E 7 IntertekTeatingS.ryices Wuxi Ltd. No8 Fub.i Rod. XishanE@nmic Dov€lorent Zon., Wui21.1101, JbnO& Chlna E.n.ir: 6n&n.'!ood3.wur@ir .n6k.m T€r +36510sa214567 NUMBER;WUXHo0 002 75 7 TEST REPORT APP],ICANT: CONCORD SEMICONDUCTOR(WIXI ) CO., I,TD. EAST 1+,ZHENFA 6 ROAD, SHUO FANG INDUSTRTAI, PARK W(IXI NATIONA], HIGHTECH DEVET,OPMENTZONE, WUXI,.]IANGSU, CHINA ATTN: ZHANG XIAOPENG DATE: AUG 05, 2 010 SAMP],E DESCRIPTlON: ONE(1)PIECB OF SUBMITTED SAMPLE SAID TO BE TBLACtr EPOIcf. ITEM NAME EPOXY MOLDING COMPOI]ND. VENDOR COOKSONELECTONICS SEMICONDUCTOR PRODUCTS. cK- 2000A. COMPONENTOR PART NO. P b , C d , H g , C T V I , P B B P B D E ,F , C I , B T , I . TEST ITEM TESTS CONDUCTED : AS REOI]ESTEDBY THE APPI]ICANT, FOR DETAILS RBPER TO ATTACHED PAGE{S} SUMMARY: TBSTED S.M@I,E SI'BMITTED SAI{PLE STAI{DA.RI) WITH REFERENCE TO TEST METHOD OF IEC 6232I EDITION 1.0: 2008 AND MAXIMTJMCONCEI\TTRATION],IMTTS QUOTED FROM ROHS DIRECTIVES 2OO2/ 95/EC AND AMENDMENT 2 O O 5/ 6 r a / E C RESUI,T PASS TO BE COI TINUED PREPARED A]'ID CHECKED BY: FOR INTERTEK TESTING SERVICES WUXI LTD JESSICA ],U GENERAL MANAGER PAGE 1 0 F 7 Inte ek Testing ServicosWuxi Ltd. No.3 Fubri R@d, X6hdn Eoionic O.v6lopm.nl zono wui 21,1101, Jianls China Fax +36 510 33200423 E-frail@isune4oodswuxi@nn€n.k.@ TEST REPORT NUIVIBER:wuxHo0002 7s 7 TESTS CONIUCTBD (A) TEST RESULT SUMMARY: TESTI}IG ITEII CADMIIIM (cd) CONTENT (mg/kg) LEAD (Pb) CONTENT (mqlKq ) MERCURY (Hg) CoNTENT (mg/kg) (Cr"') CHROMIITM (vI) CONTET,IT (ng/kg) IFOR NON-METAI) POIJYBROMINATED BIPHENYLS (PBBS) (mg/Kq ) MONOBROMOBIPHENYIIS (MonoBB) DIBROMO BIPHENYLS (DiBB) TRIBROMO BIPHENYI,S (TT1BB) RESI'],7 ND ND ND ND ND ND ND ND ND ND TETRABROMO BIPHENYLS (TeTraBB) PENTABROMOBIPHENYLS (PenIaBB) HEXABROMO BIPHBNYLS (HexaBB) HEPTABROMO BIPHENYLS (HeptaBB) OCTABROMOBIPHENYLS (OCIABB) NONABROMOBIPHENYLS {NonaBB) DECABROMOBIPHENYL (DecaBB) POLYBROMINATED DIPHENYL ETHERS (PBDES MONOBROMODIPHENYL ETHERS (MonoBDE) ND ND ND ND (mg,/kg) DIBROMODIPHENYL ETHBRS (DiBDB) TRIBRO}',IO DIPT,IENfL ETHERS (TTiBDE) TETRABROMO DTPHBNYLETHERS (TetraBDE) ND ND ND ND PENTABROMO DIPHENYL ETHERS (PentaBDE) HEXABROMODIPHENYL ETHERS (HexaBDE) ND HEPTABROMO DIPTIENYL (I{eptaBDE) ND ETI'IERS ND ND OCTABROMODIPHENYI, ETHERS (OctaBDB) (NonaBDE ND NONABROMODIPHENYT ETHERS ) ND DECABROMODIPHENYI, ETHER (DecaBDE) REMARK: rnglkg = MILLIGRAM PER KILOGRAM BASED ON DRY WEIGT{T= ppm ND = NOT DETECTED TO BE CONTINUED PAGE 2 0 F 7 Inte ek Tosting ServlcesWuxi Ltd. No.8Fub.i Rcd, XishanEmomic o€v€lopm.nlzoie. wun 21,1101, Ji€n€s.China 4s67 Fd:+3651034200423E nail6sum.Eoods.tui@inlertok.@m T.l +355101321 TEST REPORT NUMBER:WIXHo0 002 757 TESTS CONDUCTED {B) RoHS REQUIREMENT: RESTRICTED SI'BSTA.!|CES CADMIIJM (Cd) 0 . 0 1 8 ( 1 00 m c / k q ) 0.1* (1000 mq/kq) 0.18 (1000 mclkq) 0.1? (1000 rnqlkq) LEAD (Pb) MERCURY (Hg) CHRoMIUM(vT ) (cr"-) POLYBROMINATED BIPHENYLS (PBB6 ) 0.1* (1000 mg/kq) POIJYIIROMINATED DIPHENYL ETHERS (PBDES) 0.1* (1000 mq/kc) THE ABOVE LIMITS WERE QUOTED FF.OM 2OO2/95/EC AND AMEMDMENT 2 0 0 s l 6 1 8 / E C F O R HOMOGENEOUSMATERIAL. {c) TEST METHOD; TBSTI}IG ITEU CADMII'M (Cd) COIIIENT REPORT1116 I,IIIIT TESTI}IG IIETEOD WITH REFERENCETO IEC 62321 EDITION 1.0: 2008, BY ACID DIGESTION AND DETERMINEDBY ICP. 2 r'|.g/kg oEs LEAD (Pb) CONTENT WITH REFERENCETO IEC 62321 EDITION 1.0: 2008, BY ACID DIGESTION AND DETERMINED BY ICP- MERCURY (Hg) coNTEllt W]TH RBFERENCETO IEC 62321 EDITION 1.0: 2008. BY ACID D]GESTION AND DETERMINED BY ICP- 2 mg/kg oEs 2 ntS/kg oBs CHROMII]M {VI) {Cr"') CONTENT (FOR NON-METAL) WITH REPERENCB TO 7EC 52327 EDITION 1.0: 2008, BY ALKALINE D]GESTION AND DETERMINED BY UVVIS SPECTROPHOTOMETER 1.nglkg POLYBROMINATED BIPHENYLS (PBBS)& POIIYBROMINATED DIPHENYL ETHERS {PBDES) WTTH REFERENCETO IEC IEC 62321 EDITION 1.0: 2008, BY SOL1ENT EXTRACTION AI.ID DETERMINED BY GC/MS A}ID FI'RTHER HPLC CONFTRMATION WHEN NECESSARY. 5 mg/kg D A T E S A I , I P L ER E C E M D : A U G 0 2 , 2 O L O TBSTING PERIOD:AUG 02, 2O1-OTO AUG 05, 2010 TO BE CONTINUED PAGE 3 OF 7 Inle ek TeatingServicels Wuxl Ltd. c D€ldopm.nt zone. wqi 214101,Jiang$, chi.. +35s1033214567 +3651036200423 T.l Fd E-mat:6is!meo.d. wun@ denek @m TEST REPORT NUMBER:mlxHo 0 002 757 TBSTS CONDUCTED (D) MEASUREMENT FLOWCHART TEST FOR Cd/ pb / Hg / Cr (Vr) /pBBs/pBDEs CONTET\ITS REFERENCESTANDARD: 7EC 62321 EDITION 1.0r 2OO8 SAT.{PUNC/GRINDINC OR CIATINS IIPROPRIATE ACID.T I f-""."*"___l I ExrRlcrroN oR I V I I sor.vExrr Exrr.Acrrolr -----r--V t*,."-**'"'*l ---------r------| I *rRAcr .aND Mlxr L.r r,rrrE I I V INORGANIC (ANN ],UO/FRBD WANG/AI,LY WAN) ORGANIC {\]ENNY XU/CHERRY SUN) REMARKS: *1: LIST OF APPROPRIATE ACID: CHEMIST: MATERIAL PO],YMERS META],S ETECTRONICS ACID ADDED FOR DIGESTION HNO3. HCI , HF, HrOr.H3BO3 HNO3.HC1 , HF ttNor HcI, H2o2 HBF4 *2: IF THE RESITLT OF SPOT TEST IS POSITIV"e, C!{ROMIUMVI WOULD BE DETERMINEDAS DETECTED. TO BE COIfTINUED PAGE 4 OF ? IntedekTe6tlngServlceaWuxlLtd. No.8 Fub!, Re4 x3h.n Edomic D6v€ropm6ntzon€. wud 214101,Ji.ig&, Chi@ T.l +35510332145€7 Fd: +36510 33200423 Enil: @nsumrlpo&.wut@ir €n€k6m TEST NEPORT NUMBER: WUXHo0002 75 7 TESTS CONDUCTED ( I ) TEST RESI]],T SI]MMARY IAIJOGEN CONIENT ; TESTING ITEI,I (F) FLUORINE COIIIEITII CH],ORINE (Cl) CONTEIfI BROMINE (BT) COlfTEIflI IODINE {I) COITTTEIIT RESIII,T (ppm) ND 105 ND ND ppm = PARTS PER MILLION = mg/kg = NOT DETECTED ND DATE SAMPLE RECEM: AUG 02, 2010 TEST PERIOD: AUG 02, 2010 TO AUG 05, 2010 REMARKS : II ) TEST I,IETHoD TESTING ITEM H A L O G E N( F , C l , Br,I ) corflrENT REMARKS : REPORTING LIMIT TEST]NG METHOD WITH REFERENCETO IEC 511892.2406 BY COMBUSTIONFLASK AND DETERMINBD BY ION CHROMATOGRAPHY = OUAI{TITATION IJIMIT REPORTING I,IMIT 50 ppm OF ANA],YTE IN SAMPI,E TO BE CONTINUED PAGE 5 OF ? IntertekTestlng SorvicesWuxi Ltd, No.8Fubd Red X5hanE60nic Dov.loom€nlzon.. wui214lo1,Jianl$. chin. Fa* +365i0 3a200423 [email protected].@n TEST REPORT NUMBERI WIXHo 0002 757 TESTS CONDUCTED (m) MEASUREMENT FrrowcraRT : TEST FOR HALOGEN CONTENT REPERENCEMETHOD: IEC 61189-2 TEST 2C12 SAI"]PIING/GRINDING OR CUTTING ]\DD ABSORBENT IN A COMBUSTION FLASK & PIJACE WEIGHED S,IWPLE IN FILL THE COMBUSTION FI,ASK WITH OXYGEN IGNITE THEN LEAVE THE FIIASK AT ROOM TEMPERATURE ANY TEST SPECIMET,I IN TI1E COi.IBUSTION FI.qSK? TRANSFER TI{E ABSORBSIT VOLUMETRIC FI,ASK INTO A CHEMIST: FRED WANG/ALLY WAN TO BB CONTINUED PAGE 6 OF 7 In:ertekTesting SerylceaWuxi Ltd. R@d, Xdhan €domic D.v€lopmcnl Zoi.. wd 214101,Ji.ng$, Chin. +a6s1033214s67 Fd:+3651033200423 E-mal:6sufi.rgo.disut@nlertok@m No.3 Futl TEST REPORT NUMBER:WUXHOO OO275 7 TESTS CONDUCTED PHOTO END OF REPORT PAGE 1 0 8 1 lnte.tek Testing ServicesWuxl Ltd. No.8 Fuk! R@d. Xshan E6iomic Oev.{6pn€ zoi6 wwj 214101,Ji€ng$, Chin. E-m.iri deum6lgoodssdr@intsr€k.@m NTMBER: WIjXHo0002Z66 APPLICANT: (wIxI) CONCORDSEMICONDUCTOR CO., LTD. EAST 1#, ZHENFA 6 ROAD, SHUO FANG INDUSTRIAII PARK WI]XT NATIONAL HTGHTECH DEIBLOPMEI\TT ZONE, WI.].XI, rf IANGSU. CHINA ATTN: ZHANC XIAOPENG SAMPLE DESCRIPTION: ONE{1}PIECE OF SUBMITTED PLASTIC BODY. ITEM NAME : VENDOR : COMPONENTOR PART NO. : TEST ITEM : DATE: AUG 06, SAMPLE SAID TO BE : SITJVER METAIJ pM TIN PLATING-SITID. BANDL ( KIJNSHAN) IIVIERNATIONAL PURE IIATTE TIN. 2O1O A}rD BIACK CO., P b , C d ,H 9 , C r v I , P , C l , B r , 1 . TESTS CONDUCTED: AS REOUESTED BY THE APPLICAI{T, FOR DETAILS REFER TO ATTACHED PAGE{S) TO BE CONTINUED PREPARED AND CHECKED BY: FOR IMIERTEK TESTING SERVICES WUXI LTD. .]ESSICA LU GENERAI, MANAGER PAGE I IntertekTestingSorvicosWuxi Ltd. No.3Fub.' Re4 X3h.n Eononic Devdotne ZoG, Wryi21,t101, Jt..O&.China T.I +365103321 4s67 [email protected] OF 7 TEST REPORT NUMBER:WUXHo 0 002 76 6 TESTS CONDUCTED tA) TEST RESULT SUMI,IARY: TBSTING ITEU q4lqruM (cd) coNTENr (ng/ks) /pLArrNG RBSI'IJT ND 47 ],EAD (Pb) CONTENT (ftrglKg) /PL.ATING MERCURY (Hg) CONTENI (mg/kg) /PI,ATING ND (VT) (cr.T) CHROMIUM (BY RESUI,T ND BOILING WATER EITRACTION ON METAL ) (mg/kg WITH 5 Ocro2) REMARK: mglKg = MILLIGRA]VI PER KILOGRAM BASED ON DRy WEIGHT= ppm m g / k g W I T H 5 o c m ' = MILLIGRAM PER KIIJOGRAM WITH 50 SOUARE CEITITlMETER ND = NOT DETECTED TEST COMPONENT : SIIIVER METAI PIN PLATING. (B) RoHS REOUIREMENT: RESTRICTED SI'BSTANCES LIXITS CADMIUM (Cd) 0 . 0 1 E ( 1 00 m g / k g ) LEAD ( Pb) 0.1* (1000 rnc/kq) MERCURY (Hg) 0.1* {1000 mq/kq) (cr'*) CHROMIIIM (VI) 0.19 (1000 mq/kq) THE ABOVE LIMITS WERB QUOTED PROM 2OO2/95/EC AND AMENDMBNI 2OO5/ 678 /EC FOR HOMOGENEOUSMATERIAL. TO BE CONT]NUED PAGE 2 OF 7 IntertekT6ting SorvtcesWuxiLtd. No.8Fubd Re4 x3h.n E@ionic D.vdorm..t Zorc woi 21itlo1,Ji.n!$, chin. T€l €6 5103a211('67 Fe: +3651033200,t23 E-m.U:6sum.qo.&.wul@inr€rtok.@n TEST REPORT NUMBER: WIIXHo00 02 756 TESTS CONDUCTED (c) TEST METHOD: REPORTING IJIt[IT TBSTI}ICI ITEU IESTING UETHOD CADMIT]M (Cd) CONTENT WITH REFERENCE "TO IEC 62321 EDITION 1.0: 2008, BY ACID DIGESTION A]{D DETERMINED BY ICP- LEAD (Pb) CONTEITT WITH REPERENCETO IEC 62321 EDITION 1.0: 2008, BY ACID DIGESTION AND DETERMINED BY ICP- MERCURY {Hg) CONTENT WITH REFERENCE'IO TEC 5232A B D I T T O N1 . 0 : 2 0 0 8 , B Y A C I D DIGESTION AND DETERMINEDBY ICP- 2 r.|.g/kg oEs 2 ng/kg oEs 2 r|.g/kg oEs CHROMIW (VI) (cr6*) CoNTENT (FOR METAI,) WITH REFERENCETO IEC 62321 EDITION 1,0: 2008, BY BOILING WATER EXTRACTION AND DETERMINED BY I]V-VIS SPECTROPHOTOMETER DATB SAMPLE RECEMD:AUG 02 , 201,0 TESTING PERIOD:AUG 02, 2010 TO AUc 05, wITg s'ocma (IN TESTING SOLUTION) 2010 TO BE CONTINUED PAGE 3 OF 7 Inteatek T6ting ServtcesWuxiLtd. No.8 Fubri R@4 Xsh.n Eonmlc O@lrtmnt Z!8, wui214101, Jian!$ Chin€ T6l +s651033214s67 Fd:+365103A200423 E-m.it [email protected] TEST REPORT NUMBERI WUXHo0 002 765 TESTS CONDUCTED (D) MEASIJREMENT FLOWCHART: (VI ) CONTENTS TEST FOR cA/Pb/Hg/Cr REFERENCE STANDARD: IEC 6232L EDITION SIXFI]ING/GiIIIDING MATERIA'-, DIGESf 1 0: 2008 OR CTITTING THE CONIIRI{ THE TESTED S}MPLES ARE TOTAI'JY A}IATYZED BY ICP-OES WATER AND ADD DI PIIENI'I! - CHEMIST: INORCAIrIIC (ANN LUO/FRBD WANG/ALLY WAN) REMARKS : *1: IrIST OF APPROPRIATE ACID: MATERIA], ACID A.DDED FOR DIGESTION PO],YMERS t$Ior Hcl, HF,ll,o, HaBOI METAIJS r{No3.Hc1, HF E],ECTRONICS H N O 3H C I , H ' O ' H B F 4 *2: IF THE RBSULTOF SPOT TEST IS POSITI1i8, CHROMIIJM VI WOULD BE DETERMINEDAS DETECTED. TO BE CONTINUED PAGE 4 OF 7 IntertekTesting ServicesWuxi Ltd. No.3Fubd R@d,X.ha. E@nomic D.vdopn€d zoie wu, 214101, Jiaio&.Chin. T6l +365103s214567 Fd: +3€51033200,123 E-m.i: qsum6Eood..wui@inGibk @n TEST REPORT NUUBER: wtIXHo0002766 TESTS CONDUCTED ( I ) TEST RESI'LT SIJI.,IMARY IALOGEN CONTENT : TESTING ITEM (F) FI,UORINE CONTENT CHLORINE (C1) CONTENT BROMINE {Br) CONTENT ]ODINE (I) CONTEIfI RESUI,T (PPN) ND ND ND ND REMARKS : ppm = PARTS PER MILLION = mg/kg = NOT DETECTED l{D DATE SAMPLE RECBIVE: AUG 02, 2010 TEST PERIOD: AUG 02, 2O1O TO AUG 05. 2O1O I[ ) TEsr METHoD TESTING ITAM TALOGEN(F, CI, CO}ITENT REMARKS : Br,I) TESTING METHOD REPORTING LIM]T WTTH REFERBNCETO IEC 511892t2OOG BY COMBUSTIONFLASK AND 50 ppn DETERMINED BY ION CHROMATOGRAPHY REPORTING LI}',IIT = OUANTITATION TIMIT OF ANALYTE IN SAMPLE TO BE CONTINUED PAGE 5 0 F 7 Inte ek TestlngServlcesWuxl Ltd, No.3 Fubli R@d, Xsh.n E@nomic D.tdopm€hl Zon. Wui 214101,Ji.n!$. Chin. +36 T.l 510 3321 4567 Fs: +33 510 AA200423 E-m.ili m.um.qoodauxi@i.'tdt6k.on TBST REPORT NIrI{BER: WUXHo00 02 766 TESTS CONDUCTED {M) MEASUREMENT FI,oWCHART: TEST FOR T{AI,OGEN COIIIENT REFERENCEMETHOD: lEC 67789-2 TEST 2CI2 SA}IPI,ING/GRINDING OR CTITTING ADD ABSORBEIII IN A COMBUSTION FIJASK & PIACE WEIGI{ED S.a.I4PI'EIN FILL THE COMBUSTION FLASK WITH OXYGEN IGNITE TIIEN LEAVE TIIE FIIASK AT ROOM TEMPERATURE AIiIY TEST SPECIMEN IN TIIE COMSUSTION FI,ASK? TRANSFER THE ABSORBENT ]I.IIO A VOIJUMETRICFLASK CHEMIST: FRED WA}IGI ALLY I{AN TO BE CONTINUED PAGE 5 OF ? IntertekTestingServlcesWuxlLtd. No.3Fubl, R€4 Xshn EonomicO.\dopm.nl Zon. wln 214101, Ji.ig&, China Tcl:€6 51033214537F*.365103320 0423 E-mil:6sumEo.de.wun@irn€ibk @n TEST REPORT NUMBER; WIXHoo 002 766 TESTS CONDUCTED PHOTO END OF REPORT PAGE 7 OF 7 IntertekTesting Se.vicesWuxi Ltd. Nog Fub.i Rodd. XEh.n E@tsi. D.vdop.n.nl Zon., wwj 214101,.rangsu,Chia *36 510 3421 4567 Far +36 510 3320 0423 E-roir: @n.um€o.d. [email protected].@m TBST REPORT APPLICANT: NUMBER: w u x H o 0 0 0 2 7 3 6 CONCORD SEMICONDUCTOR(wuxr ) CO., LTD. EAST 1#, ZHENFA 5 ROAD, SHUO FANG INDUSTRIAI, PARK WUXI NATIONAL H]GHTECH DEVELOPI.4ENTZONE, wlIXI...]IANGSU. CHINA ATTN: ZHANG XIAOPENG DATE: AUG 06, 201-0 SAMPLE DESCRIPTION: ONE(1)PIECE OF SI'BMITTED SAMPLE SAID TO BE : COPPER ETA],. ITEM NAME CLIP. VENDOR G-SIIANK PRECISION MACHINERY ( s u z H o uc) o . , t T D . COMPONENTOR PART NO. COPPER, Pb, Cd, Hg. CrVI . TESTS CONDUCTED: AS REQI]ESTED BY Ti]E APPTICANT, SUTVIMARY: TESTED SAIIPLA SUBMIITED SAMPLE FOR DETAITJS REFER TO ATTACHED PAGE(S) STAI{DA.RD WITH REFERENCE TO TEST METHOD OF IEC 6232I EDITION 1.0: 2008 AUD MAXIMT]M CONCENTRATION LTMITS QUOTED FROM RoHS DIRECTIVES 2OO2/ 95 /EC AND AIVIENDMEI{T RESI'I,T PASS 200s/6aa/Ec TO BE COIfIINUED PREPARED AND CHECKED BY: FOR IIflTERTEK TESTING SERVICES WUXI LTD. .JESSICA LU GENERAI, MANAGER PACE 1 0 F 5 IntertokToatlngServlcesWuxi Ltd. llo.3 Fub.tRo.d,xi.h.n E6Mic D.wroph.it zon., wqi 214101.l.nssu,Chim €6 5103321,ts37 F.x +s551033200423 E-roit: 6n.uBgF.ds wur@ir cnekff TEST REPORT NUMBER: WIIXHo00 0273 6 TESTS CONDUCTED (A) TEST RESULT SUMMARY: TESTI}TG ITEM RESUIJT CADMIIJM (Cd) COMIENT (rnglkg ) ND LEAD (Pb) CONTENT (nq/kq) I2 MERCURY (Hg) CoNTENT (mg/kq) ND (V]) (cr.-) CHROMIIJM (BY RESUIIT ND BOIIIING WATER EXTRACTION ON METAL ) LBg/kg WITH 5 Ocm'?) REI4ARK: rng/kg = MILIrIGRAM PER KILOGRAM BASED ON DRY WEIGHT= ppm rng/kg WITH 50cn2 = MILLIGRAM PER K]LOGRAM WITII 50 SOUARB CENTIMETER ND = NOT DETBCTED (B) RoHS REQUIREMEI\IT: RESTRTCTED ST'ASTANCES CADMII'M (Cd) LEAD (Pb) MERCURY (Hg) CHROMIUM(vr) (Cr'*) rrlurrs 0 . 0 1 * (1 0 0 m s / k s ) 0.1? (1000 mq/kc) 0.1t (1000 mq/kq) 0.1* (1000 mq/kq) THE ABOVE LIMITS WERE QUOTED FROM 2OO2/95/EC AND AMENDMENT 2OO5/ 618 /EC FOR HOMOGENEOUSMATERIAL. TO BE COIfrIINUED PAGE 2 OF 5 Inte.tekT6ting ServicesWuxiLtd. No.3 Fubd R@4 Xshan E@nomic [email protected] Zore, wui211101, Jiang&. chii. Ter +36s1033214s67 Fd: +36 5r0 34200423 E-maitdsum.Eoodswi@intdt k.om TEST REPORT NITMBER: WUXHo0002?36 TESTS CONDUCTED (c) TEST METHOD: REPORTI}IG TBSTIITG TTEII TESTING I(ETSOD CADMIU}4 (Cd) CONTEI{I W]TH REFERBNCETO TEC 62321 EDITTON 1.0: 2008, BY ACID DIGESTTON AND DETERMINED BY ICP- 2 mg/kg ],EAD ( Pb) COMIENT WITH REFERENCE 'IO IEC 62321. EDITION 1.0: 2008, BY ACID DIGESTION AND DETER.},IINEDBY ]CP- 2 llr.g/kg MERCURY (Hg) CONTEIVT W]TH REFERBNCETO IEC 62321 EDITION 1.0: 2008. BY ACID DIGEST]ON AND DETERMINED BY lCP- 2 nts/kg oEs oEs oEs CHRO}.{IUM (VI ) (Cr"') CONTEN'I (FOR META],) IIITH REFERENCETO IEC 62321 SDITION 1.0: 2008, BY BOILING 7{ATER EXTRACTION AND DETERMINED BY Iry-VIS SPECTROPHOTOMETER DATE SAMPLE RECE]\ED:AUG 02, 201.0 TESTTNG PERTOD:AUG 02, 2070 TO AUG 0s, 0 . o2mg/kg WrTH 50cm' (IN TESTINS SOI,UTION) 2O1O TO BE COITIIINUED PAGE 3 OF 5 IntertekTestinq ServicesWuxi Ltd. No3 Fub.i Ro€dxi.h.n e@|mic trov€roFn.niZd., Wui 214101, .rsgeu,Chna Far +s6 51033200423 E-mil: @n$mrgoods.wur@id6n€k.m TEST REPORT NIIMBER: WUXHo0 002 735 TESTS CONDUCTED (D) MEASUREMENT FLOWCIIART: TEST FOR Cd/Pb/H!/C!: (VI ) CONTENTS REFERENCE STANDARD: IEC 62321 EDITION SAIIFIINC/CRINDINC XATERIAI,, DICIST AIPROPRIATE 1.0: 2008 OR CIJAIING TllE ACID'I S}XPI-ES ARE ToTAI,I,Y SATIR AND NDD DIPIENYL- CHEMIST: INORGANIC (ANN ],UOIFRED WANG/A],LY WAN) REMARKS : *1: LIST OF APPROPRIATE ACID: MATERIAI, POLYMERS I.,IETAtS EI,ECTRONICS ACID ADDED FOR DIGESTION t{No3.Hcl, HP, Itror.It3Bo3 tNo3. Hcl, HF H N O 3 ,H C l , l I 2 O ' . H B F 4 *2; IF THE RESITLT OF SPOT TEST IS POSITM, BE DETERI4INEDAS DETECTED. CHROMIUMVI WOULD TO BE CONTINUBD PHOTO PAGE 4 OF 5 Inteatek TestlngServlcesWurl Ltd. No.8Fctt R@d,Xi6hanEqomio D.vdopm.nl Zone. woj 214101Jlanqsu, chtne T.I +365r0 33214567 F*+4a51033200423E-mit:@Numllo.d'[email protected] TEST REPORT NUMBER: WlIXHoo002 736 TESTS CONDUCTED END OF REPORT PAGE 5 OF 5 IntertokTestingSedicesWuxi Lid. No.8Fuhi R@4 XshanE@ionic D.v.lopn€rnzon. wu 21,1101, Ji.iqs. Chin. +36 T.l 5103321,1567 Fd: +3651034200ir23 [email protected].@m