MA500RUI Series Wide 4:1 Input, 5W, High 3.5 kVDC Isolation DC/DC Converters Electrical Specifications Key Features: • 5W Output Power Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions • 4:1 Input Voltage Range • 3,500 VDC Isolation Input Voltage Range • 14 Standard Models Input Reflected Ripple Current • High Efficiency Input Filter • Compact DIP Case Output • -40°C to +85°C Operation Parameter • Metal Case Available • Low Cost Alternate Pin-Out Available Min. Typ. Max. 24 VDC Input 9.0 24.0 36.0 48 VDC Input 18.0 48.0 72.0 35 VDC mA P - P (Pi) Filter Conditions Min. Output Voltage Accuracy Line Regulation Typ. Max. Units ±1.0 % VIN = Min to Max ±0.5 % % IOUT = 25% to 100% ±0.5 Cross Regulation See Note 1 ±0.5 % Ripple & Noise (20 MHz) See Note 2 60 mV P - P ±0.02 %/°C Load Regulation Temperature Coefficient Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Isolation Voltage, See Note 3 1.5 kV Isolation Models Available Units Isolation Resistance Isolation Capacitance Min. 3 Seconds 3,500 500 VDC 1,000 100 kHz/0.1V Switching Frequency Typ. Max. Units VDC M 60 100 pF 400 kHz Environmental Parameter Conditions Operating Temperature Range Ambient Operating Temperature Range Min. Typ. Max. Units -40 +25 +85 °C +100 °C +125 °C 95 % Case Storage Temperature Range -40 Cooling Free Air Convection Humidity RH, Non-condensing Physical Case Size 1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm) Case Material, Plastic MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Non-Conductive Black Plastic (UL94-V0) Weight, Plastic Case 0.44 Oz (12.5g) Case Material, Metal Nickel-Coated Copper With Non-Conductive Base (UL94-V0) Weight, Metal Case 0.53 Oz (15g) Reliability Specifications Parameter Conditions MTBF MIL HDBK 217F, 25°C, Gnd Benign Min. Typ. Max. 1.0 Units MHours Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature Min. Typ. Max. 24 VDC Input -0.7 40.0 48 VDC Input -0.7 80.0 1.5 mm From Case for 10 Sec 260 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Units VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number Voltage (VDC) Output Current (mA) Efficiency Fuse Reflected Capacitive Ripple Rating Load Current Slow-Blow (µF, Max) Voltage Current Current (VDC) (mA, Max) (mA, Min) 3.3 1,200.0 300.0 68 35.0 2,200 600 20 5.0 1,000.0 250.0 73 35.0 1,000 600 20 12.0 416.0 105.0 74 35.0 470 600 333.0 84.0 74 35.0 470 600 ±500.0 ±125.0 77 35.0 ±1,000 600 ±208.0 ±53.0 82 35.0 ±220 600 Nominal Range Full-Load No-Load MA524S-03RUI-xx 24 9.0 - 36.0 243.0 20 MA524S-05RUI-xx 24 9.0 - 36.0 285.0 MA524S-12RUI-xx 24 9.0 - 36.0 282.0 MA524S-15RUI-xx 24 9.0 - 36.0 282.0 20 15.0 MA524D-05RUI-xx 24 9.0 - 36.0 271.0 20 ±5.0 MA524D-12RUI-xx 24 9.0 - 36.0 254.0 20 ±12.0 (%, Typ) (mA Typ) (mA) MA524D-15RUI-xx 24 9.0 - 36.0 254.0 20 ±15.0 ±166.0 ±42.0 82 35.0 ±220 600 MA548S-03RUI-xx 48 18.0 - 72.0 118.0 15 3.3 1,200.0 300.0 70 35.0 2,200 300 MA548S-05RUI-xx 48 18.0 - 72.0 143.0 15 5.0 1,000.0 250.0 73 35.0 1,000 300 MA548S-12RUI-xx 48 18.0 - 72.0 141.0 15 12.0 416.0 105.0 74 35.0 470 300 MA548S-15RUI-xx 48 18.0 - 72.0 137.0 15 15.0 333.0 84.0 76 35.0 470 300 MA548D-05RUI-xx 48 18.0 - 72.0 145.0 15 ±5.0 ±500.0 ±125.0 72 35.0 ±1,000 300 MA548D-12RUI-xx 48 18.0 - 72.0 139.0 15 ±12.0 ±208.0 ±53.0 75 35.0 ±220 300 MA548D-15RUI-xx 48 18.0 - 72.0 139.0 15 ±15.0 ±166.0 ±42.0 75 35.0 ±220 300 For the alternate pin-out (see page 4) , add suffix “P2” to model number (i.e. MA524S-05RUI-P2) Model Number Notes: 1. Cross regulation is measured with the output being tested at 100% load while the other output is varied from 25% to 100% load. 2. See the typical connection circuit on page three for typical external filtering components. For help with a specific model or layout issue, contact the factory. 3. Isolation voltage is specified for Input to output. On units with the optional metal case, the isolation voltage for Input - Case and Output - Case is 1,000 VDC. 4. Operation at no-load will not damage the unit, but they may not meet all specifications. To meet all specifications, a minimum load of 33% should be maintained. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. NEW DIP DC/DC Converter Families From MPD Series Power Input Range Isolation MA100X-xxRW MA100X-xxRWI MA100X-xxRU MA100X-xxRUI MA200X-xxRW MA200X-xxRWI MA200X-xxRU MA200X-xxRUI MA300X-xxRW MA300X-xxRWI MA300X-xxRU MA300X-xxRUI MA400X-xxRW MA400X-xxRWI MA400X-xxRU MA400X-xxRUI MA500X-xxRW MA500X-xxRWI MA500X-xxRU MA500X-xxRUI MA600X-xxRW MA600X-xxRWI MA600X-xxRU MA600X-xxRUI 1W 1W 1W 1W 2W 2W 2W 2W 3W 3W 3W 3W 4W 4W 4W 4W 5W 5W 5W 5W 6W 6W 6W 6W 2:1 2:1 4:1 4:1 2:1 2:1 4:1 4:1 2:1 2:1 4:1 4:1 2:1 2:1 4:1 4:1 2:1 2:1 4:1 4:1 2:1 2:1 4:1 4:1 1.5 kVDC 3.5 kVDC 1.5 kVDC 3.5 kVDC 1.5 kVDC 3.5 kVDC 1.5 kVDC 3.5 kVDC 1.5 kVDC 3.0 kVDC 1.5 kVDC 3.0 kVDC 1.5 kVDC 3.5 kVDC 1.5 kVDC 3.5 kVDC 1.5 kVDC 3.5 kVDC 1.5 kVDC 3.5 kVDC 1.5 kVDC 3.0 kVDC 1.5 kVDC 3.0 kVDC Derating Curve Visit our website or contact the factory for more information. 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Typical Connection The diagram above illustrates a typical connection of the MA500RUI series for applications that require meeting conducted EMC standards. The units do not require external components to operate as specified. For applications requiring very low output noise levels, the output filtering capacitors (C3 is a low ESR electrolytic & C4 is a ceramic) will often be sufficient. Care must be taken in choosing output capacitors not to exceed the capacitive load specification for the unit. For dual output units, output capacitors should be connected from each output to common. All external components should be mounted as close to the unit as possible. The recommended values for components are: Component 48 VIN 24 VIN C1 220 µF/100V 220 µF/100V LCM 12 µH 12 µH 470 pF/4kV MLCC 470 pF/4kV MLCC C2 100 µF 100 µF C3 4.7 - 10 µF 4.7 - 10 µF C4 Typical Board Layout: With External Filter Components, Single Output Typical Board Layout: With External Filter Components, Dual Output Input noise and surge suppression modules are available for a number of MPD DC/DC power supplies. Contact the factory for more information. MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Mechanical Dimensions Standard Units - Plastic Case Standard Units - Metal Case Pin Connections s Pin 2 3 9 11 14 16 22 23 Single Output -VIN -VIN No Pin No Connection +VOUT -VOUT +VIN +VIN Pin 2 3 9 11 14 16 22 23 Dual Output -VIN -VIN Common -VOUT +VOUT Common +VIN +VIN For the alternate pin-out, add suffix “P2” to model number (i.e. MA524S-05RUI-P2) Alternate Pin-Out Units - Plastic Case Alternate Pin-Out Units - Metal Case Pin Connectio tions Pin 1 2 3 10 11 12 13 14 15 22 23 24 Single Output +VIN No Connection No Connection -VOUT +VOUT -VIN -VIN +VOUT -VOUT No Connection No Connection +VIN Pin 1 2 3 10 11 12 13 14 15 22 23 24 Dual Output +VIN -V VOUT Common Common +VOUT -VIN -VIN +VOUT Common Common -VOUT +VIN MicroPower Direct Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Pin 1 is marked by a “dot” or indentation on the top of the unit We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]