Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 6W Output Power
Input
Parameter
• 4:1 Input Voltage Range
Input Start Voltage
• 3,000 VDC Isolation
• 16 Standard Models
Under Voltage Shutdown
Input Filter
• Single & Dual Outputs
Output
• Compact DIP Case
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
• -40°C to +85°C Operation
• Industry Standard Pin-Out
2:1 Input Range
Models
Available
Typ.
8.0
16.0
Conditions
Typ.
±1.0
±1.0
±0.1
±0.6
Min.
Dual Output, Balanced Loads
VIN = Min to Max
IOUT = 0% to 100%
See Note 1
Over Line, Load & Temp.
Ripple & Noise (20 MHz)
1.5 kV Isolation
Models
Available
Conditions
Min.
24 VDC Input
7.0
48 VDC Input 14.0
24 VDC Input
48 VDC Input
(Pi) Filter
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Overload Protection
Output Short Circuit
300
±3.0
±0.01
Foldback
110
145
Continuous (Autorecovery)
25% Load Step Change
Max.
9.0
18.0
8.5
17.5
Units
Max.
±2.0
±2.0
±0.5
±1.2
70
100
600
Units
%
%
%
%
±0.02
VDC
VDC
mV P - P
µSec
%
%/°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Conditions
60 Seconds
500 VDC
100 kHz/1.0V
Standard
See Note 3
See Note 3
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Min.
3,000
1,000
Typ.
Max.
1,000
330
Units
VDC
M
pF
kHz
Level
Class A
Class A
Criteria A; ±8 kV Air ±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±1 kV
Criteria A; 10V/m
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-50
Free Air Convection
RH, Non-condensing
Max.
+85
+100
+125
Units
°C
°C
°C
95
%
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.45 Oz (12.8g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
800
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MA624S-05RUI
MA624S-05RUI
MA624S-12RUI
MA624S-15RUI
MA624S-24RUI
MA624D-05RUI
MA624D-12RUI
MA624D-15RUI
MA648S-03RUI
MA648S-05RUI
MA648S-12RUI
MA648S-15RUI
MA648S-24RUI
MA648D-05RUI
MA648D-12RUI
MA648D-15RUI
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
24
9.0 - 36.0
214
20
24
9.0 - 36.0
313
20
24
9.0 - 36.0
298
20
24
9.0 - 36.0
298
20
24
9.0 - 36.0
298
20
24
9.0 - 36.0
260
20
24
9.0 - 36.0
298
20
24
9.0 - 36.0
298
20
48
18.0 - 75.0
107
10
48
18.0 - 75.0
156
10
48
18.0 - 75.0
149
10
48
18.0 - 75.0
149
10
48
18.0 - 75.0
149
10
48
18.0 - 75.0
130
10
48
18.0 - 75.0
149
10
48
18.0 - 75.0
149
10
Output
Voltage
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
1,200.0
1,200.0
500.0
400.0
250.0
±500.0
±250.0
±200.0
1,200.0
1,200.0
500.0
400.0
250.0
±500.0
±250.0
±200.0
Notes:
1. When measuring output ripple, it is recommended that an external 3.3 µF ceramic capacitor be
placed from the +VOUT pin to the -VOUT pin for single output units and from each output to common
for dual output units.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
3. Operation at no-load will not damage these units.
4. An external 220 µF/100V capacitor connected across the input pins is required to meet
EN61000-4-4 and EN61000-4-5.
5. Dual output units may be connected to provide a 10, 24 or 30 VDC output. To do this, connect the
load across the positive (+VOUT) and negative (-VOUT) outputs and float the output common.
6. The converter should be connected to a low ac-impedance source. An input source with a highly
inductive impedance may affect the stability of the converter. In applications where the converter
output loading is high and input power is supplied over long lines, it may be necessary to use
a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR
<1.0 at 100 kHz) capacitor be mounted close to the converter. For 24V input units a 4.7 µF is
recommended; and for 48V units a 2.2 µF.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table
above for the correct rating.
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
Fuse
Reflected Capacitive
Ripple
Rating
Load
Current
Slow-Blow
(µF, Max)
Efficiency
(%, Typ)
(mA Typ)
77
80
84
84
84
80
84
84
77
80
84
84
84
80
84
84
(mA)
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
470
470
100
100
47
±100
±100
±100
470
470
100
100
47
±100
±100
±100
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
800
800
800
800
800
800
800
800
Derating Curve
Mechanical Dimensions
For 1.5 kV Isolation, See MA600x-xxRU Series Datasheet
For 2:1 Inputs, See MA600x-xxRW Series Datasheet
Pin Connections
Pin
Single
Dual
2, 3
9
11
14
16
22, 23
-VIN
No Pin
NC
+VOUT
-VOUT
+VIN
-VIN
Common
-VOUT
+VOUT
Common
+VIN
NC: No Connection
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.x = ±0.02 (±0.50)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]