MA500RW Series Wide 2:1 Input, 5W, High Performance, DIP DC/DC Converters Electrical Specifications Key Features: • 5W Output Power Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Parameter Conditions • 2:1 Input Voltage Range • 1,500 VDC Isolation Input Voltage Range • 30 Standard Models • High Efficiency • Compact DIP Case • -40°C to +85°C Operation Typ. Max. 9.0 12.0 18.0 24 VDC Input 18.0 24.0 36.0 48 VDC Input 36.0 48.0 72.0 Input Reflected Ripple Current 35 VDC mA P - P Output Parameter Conditions Output Voltage Accuracy • Low Cost Line Regulation Min. Typ. Max. Units ±1.0 % VIN = Min to Max ±0.5 % Load Regulation IOUT = 25% to 100% ±0.5 % Load Regulation See Note 1 ±0.5 % Ripple & Noise (20 MHz) See Note 2 60 mV P - P ±0.02 %/°C Temperature Coefficient Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Isolation Voltage, See Note 3 3.5 kV Isolation Models Available Units (Pi) Filter Input Filter • Metal Case Available Alternate Pin-Out Available Min. 12 VDC Input Isolation Resistance Isolation Capacitance Min. 3 Seconds 1,500 500 VDC 1,000 100 kHz/0.1V Switching Frequency Typ. Max. Units VDC M 60 100 pF 400 kHz Environmental Parameter Conditions Operating Temperature Range Ambient Operating Temperature Range Min. Typ. Max. Units -40 +25 +85 °C +100 °C +125 °C 95 % Case Storage Temperature Range -40 Cooling Free Air Convection Humidity RH, Non-condensing Physical Case Size 1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm) Case Material, Plastic Non-Conductive Black Plastic (UL94-V0) Weight, Plastic Case 0.44 Oz (12.5g) MicroPower Direct Case Material, Metal Nickel-Coated Copper With Non-Conductive Base (UL94-V0) 292 Page Street Suite D Stoughton, MA 02072 USA Reliability Specifications Weight, Metal Case 0.53 Oz (15g) Parameter Conditions MTBF T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com MIL HDBK 217F, 25°C, Gnd Benign Min. Typ. Max. 1.0 Units MHours Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature Min. Typ. Max. 12 VDC Input -0.7 24.0 24 VDC Input -0.7 40.0 48 VDC Input -0.7 80.0 1.5 mm From Case for 10 Sec 260 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Units VDC °C www.micropowerdirect.com Model Selection Guide Input Model Number Voltage (VDC) Nominal Range Output Current (mA) Voltage Current (mA, Max) Full-Load No-Load (VDC) MA512S-05RW-xx 12 9.0 - 18.0 563 20 MA512S-09RW-xx 12 9.0 - 18.0 541 20 MA512S-12RW-xx 12 9.0 - 18.0 534 20 MA512S-15RW-xx 12 9.0 - 18.0 534 20 MA512S-24RW-xx 12 9.0 - 18.0 556 MA512D-05RW-xx 12 9.0 - 18.0 MA512D-09RW-xx 12 MA512D-12RW-xx 5.0 Current Efficiency (mA, Min) (%, Typ) Fuse Reflected Capacitive Ripple Rating Load Current Slow-Blow (µF, Max) (mA Typ) (mA) 1,000.0 250.0 74 35.0 2,200 1,000 9.0 555.0 139.0 77 35.0 470 1,000 12.0 417.0 104.0 78 35.0 470 1,000 15.0 333.0 83.0 78 35.0 470 1,000 20 24.0 208.0 52.0 75 35.0 220 1,000 579 20 ±5.0 ±500.0 ±125.0 72 35.0 ±1,000 1,000 9.0 - 18.0 548 20 ±9.0 ±278.0 ±70.0 76 35.0 ±220 1,000 12 9.0 - 18.0 541 20 ±12.0 ±208.0 ±52.0 77 35.0 ±220 1,000 MA512D-15RW-xx 12 9.0 - 18.0 541 20 ±15.0 ±167.0 ±42.0 77 35.0 ±220 1,000 MA512D-24RW-xx 12 9.0 - 18.0 548 20 ±24.0 ±104.0 ±26.0 76 35.0 ±100 1,000 MA524S-05RW-xx 24 18.0 - 36.0 278 12 5.0 1,000.0 250.0 75 35.0 2,200 500 MA524S-09RW-xx 24 18.0 - 36.0 274 12 9.0 555.0 139.0 76 35.0 470 500 MA524S-12RW-xx 24 18.0 - 36.0 271 12 12.0 417.0 104.0 77 35.0 470 500 MA524S-15RW-xx 24 18.0 - 36.0 267 12 15.0 333.0 83.0 78 35.0 470 500 MA524S-24RW-xx 24 18.0 - 36.0 274 12 24.0 208.0 52.0 76 35.0 220 500 MA524D-05RW-xx 24 18.0 - 36.0 282 12 ±5.0 ±500.0 ±125.0 74 35.0 ±1,000 500 MA524D-09RW-xx 24 18.0 - 36.0 274 12 ±9.0 ±278.0 ±70.0 76 35.0 ±220 500 MA524D-12RW-xx 24 18.0 - 36.0 267 12 ±12.0 ±208.0 ±52.0 78 35.0 ±220 500 MA524D-15RW-xx 24 18.0 - 36.0 267 12 ±15.0 ±167.0 ±42.0 78 35.0 ±220 500 MA524D-24RW-xx 24 18.0 - 36.0 278 12 ±24.0 ±104.0 ±26.0 75 35.0 ±100 500 MA548S-05RW-xx 48 36.0 - 72.0 135 8 5.0 1,000.0 250.0 77 35.0 2,200 250 MA548S-09RW-xx 48 36.0 - 72.0 134 8 9.0 555.0 139.0 78 35.0 470 250 MA548S-12RW-xx 48 36.0 - 72.0 130 8 12.0 417.0 104.0 80 35.0 470 250 MA548S-15RW-xx 48 36.0 - 72.0 130 8 15.0 333.0 83.0 80 35.0 470 250 MA548S-24RW-xx 48 36.0 - 72.0 135 8 24.0 208.0 52.0 77 35.0 220 250 MA548D-05RW-xx 48 36.0 - 72.0 137 8 ±5.0 ±500.0 ±125.0 76 35.0 ±1,000 250 MA548D-09RW-xx 48 36.0 - 72.0 134 8 ±9.0 ±278.0 ±70.0 78 35.0 ±220 250 MA548D-12RW-xx 48 36.0 - 72.0 134 8 ±12.0 ±208.0 ±52.0 78 35.0 ±220 250 MA548D-15RW-xx 48 36.0 - 72.0 130 8 ±15.0 ±167.0 ±42.0 80 35.0 ±220 250 MA548D-24RW-xx 48 36.0 - 72.0 135 8 ±24.0 ±104.0 ±26.0 77 35.0 ±100 250 Notes: 1. Cross regulation is measured with the output being tested at 100% load while the other output is varied from 25% to 100% load. 2. See the typical connection circuit on page three for typical external filtering components. For help with a specific model or layout issue, contact the factory. 3. Isolation voltage is specified for Input to output. On units with the optional metal case, the isolation voltage for Input - Case and Output - Case is 1,000 VDC. 4. Operation at no-load will not damage the unit, but they may not meet all specifications. To meet all specifications, a minimum load of 25% should be maintained. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. For the alternate pin-out (see page 4) , add suffix “P2” to model number (i.e. MA524S-05RW-P2) Model Number Derating Curve 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Typical Connection The diagram above illustrates a typical connection of the MA500RW series for applications that require meeting conducted EMC standards. The units do not require external components to operate as specified. For applications requiring very low output noise levels, the output filtering capacitors (C3 is a low ESR electrolytic & C4 is a ceramic) will often be sufficient. Care must be taken in choosing output capacitors not to exceed the capacitive load specification for the unit. For dual output units, output capacitors should be connected from each output to common. All external components should be mounted as close to the unit as possible. The recommended values for components are: Component 24 VIN 48 VIN 12 VIN C1 220 µF/50V 220 µF/100V 220 µF/100V LCM 12 µH 12 µH 12 µH --470 pF/2kV MLCC 470 pF/2kV MLCC C2 100 µF 100 µF 100 µF C3 4.7 - 10 µF 4.7 - 10 µF 4.7 - 10 µF C4 Typical Board Layout: With External Filter Components, Single Output Typical Board Layout: With External Filter Components, Dual Output Input noise and surge suppression modules are available for a number of MPD DC/DC power supplies. Contact the factory for more information. MicroPower Direct • 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected] www.micropowerdirect.com Mechanical Dimensions Standard Units - Plastic Case Standard Units - Metal Case Pin Connections s Pin 2 3 9 11 14 16 22 23 Single Output -VIN -VIN No Pin No Connection +VOUT -VOUT +VIN +VIN Pin 2 3 9 11 14 16 22 23 Dual Output -VIN -VIN Common -VOUT +VOUT Common +VIN +VIN For the alternate pin-out, add suffix “P2” to model number (i.e. MA524S-05RW-P2) Alternate Pin-Out Units - Plastic Case Alternate Pin-Out Units - Metal Case Pin Connectio tions Pin 1 2 3 10 11 12 13 14 15 22 23 24 Single Output +VIN No Connection No Connection -VOUT +VOUT -VIN -VIN +VOUT -VOUT No Connection No Connection +VIN Pin 1 2 3 10 11 12 13 14 15 22 23 24 Dual Output +VIN -V VOUT Common Common +VOUT -VIN -VIN +VOUT Common Common -VOUT +VIN MicroPower Direct Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) • Pin 1 is marked by a “dot” or indentation on the top of the unit We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]